DOWNLOAD Sharp DV-RW250H (serv.man5) Service Manual ↓ Size: 4.36 MB | Pages: 117 in PDF or view online for FREE

Model
DV-RW250H (serv.man5)
Pages
117
Size
4.36 MB
Type
PDF
Document
Service Manual
Brand
Device
DVD / Complete
File
dv-rw250h-sm5.pdf
Date

Sharp DV-RW250H (serv.man5) Service Manual ▷ View online

ELECTRICAL ADJUSTMENTS
D3-1
Read and perform this adjustment when repairing the
circuits or replacing electrical parts or PCB assemblies.
1. BASIC ADJUSTMENT
CAUTION
1-1: PG SHIFTER
CONDITIONS
MODE-PLAYBACK
Input Signal-Alignment Tape (JG001E)
INSTRUCTIONS
Connect CH-1 on the oscilloscope to TP102 and CH-2
to J8001.
Playback the alignment tape. (JG001E)
Press and hold the Tracking-Auto button on the remote
control more than 2 seconds to set tracking to center.
Press both CH UP button on the set and the STOP
button on the set for more than 2 seconds.
1.
2.
3.
4.
When you exchange IC and Transistor for a heat sink,
apply the silicon grease (YG6260M) on the contact
section of the heat sink. Before applying new silicon
grease, remove all the old silicon grease. (Old grease
may cause damages to the IC and Transistor.)
6.5H
CH-1
CH-2
Fig. 1-1-A
CH-1
CH-2
6.5H
Fig. 1-1-B
ELECTRICAL ADJUSTMENTS
2. ELECTRICAL ADJUSTMENT PARTS LOCATION GUIDE (WIRING CONNECTION)
D3-2
CP8301
DVD/HD MPEG PCB
POWER PCB
OPERATION PCB
DECK CD
FE HEAD
CD651
CP502
CP7301
CP7304
CD7304
VCR PCB
CD502
CD7301
CD7302
CD7303
AC IN
J653
J652
J651
V651
TP103
CP8303
TP651
OS651
CP8302
J654
CP651
CP102
J8001
TU301
J8002
TP102
CP103
AC HEAD
CD102
CP681
CP506
CP504
CD501
CP1701
CP1703
FAN MOTOR
CP7302
CP7303
CP4001
FH501
S501
CD4001
TROUBLESHOOTING GUIDE
E-1
POWER DOES NOT TURN ON
NO
(VCR SECTION)
YES
NO
YES
NO
YES
Check of T501
and peripheral circuit.
Check of V651
and peripheral circuit.
Check IC3001.
Check of T501
and peripheral circuit.
Is the voltage at
pin 30 of IC 3001
0V ?
Does display light?
Is the voltage
linked to L506 ?
TROUBLESHOOTING GUIDE
E-2
THE POWER SUPPLY CUT
Inserting a cassette
and push play button.
YES
YES
NO
NO
Does the power cut
after 3 seconds?
Check CAPSTAN DD UNIT
and CYLINDER UNIT.
Does the power cut
after about 6 seconds?
Check Q3006,Q3008
and CAPSTAN BELT.
Check the POWER BLOCK.
Page of 117
Display