DOWNLOAD Sharp SD-CX1 (serv.man10) Service Manual ↓ Size: 1.27 MB | Pages: 34 in PDF or view online for FREE

Model
SD-CX1 (serv.man10)
Pages
34
Size
1.27 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / System / Part 7 - Waveforms, Troubleshooting tables, IC tables
File
sd-cx1-sm10.pdf
Date

Sharp SD-CX1 (serv.man10) Service Manual ▷ View online

– 73 –
SD-CX1H
T
FMO
FOO
Stopped
CH1=200mV
2000/09/18   17:12:20
DC   10:1
CH2=1V
DC   10:1
100ms/div
(100ms/div)
NORM:10kS/s
1
2
=Record Length=
Smoothing :   ON
CH1  :      0.000V
CH2  :        0.00V
Main  :         10K
Zoom  :         5K
Mode  :   AUTO
Type   :   EDGE CH1
Delay  :                102.3ns
Hold off  :         MINIMUM
CH3  :        0.00V
CH4  :        0.00V
BW   : 20MHz
=Trigger=
=Filter=
VAR
CH1  V/DIV
CAL
=Offset=
CH1
  V/DIV
  200mV
Track jump
9
Feed motor and tracking output 
during the track jump
10
IC3 40 pin
IC3 33 pin
T
FOO
FO+
FO-
Stopped
CH1=200mV
2000/09/18   15:14:35
DC   10:1
CH2=2V
DC   10:1
CH3=1V
DC   10:1
1s/div
(1s/div)
NORM:10kS/s
1
2
3
=Record Length=
Smoothing :   ON
CH1  :      0.000V
CH2  :        0.00V
Main  :         10K
Zoom  :         5K
Mode  :   AUTO
Type   :   EDGE CH1
Delay  :                102.3ns
Hold off  :         MINIMUM
CH3  :        0.00V
CH4  :        0.00V
BW   : 20MHz
=Trigger=
=Filter=
VAR
CH1  V/DIV
CAL
=Offset=
CH1
  V/DIV
  200mV
It is actuated 
normally.
When a cap was 
closed without a 
disc.
4
Focus search
5
10
IC3 33 pin
IC1 4 pin
IC1 3 pin
T
IC3 41 pin
IC1 26 pin
IC1 25 pin
Stopped
CH1=1V
2000/09/18   16:42:08
DC   10:1
CH2=1V
DC   10:1
CH3=5V
DC   10:1
500ms/div
(500ms/div)
NORM:2kS/s
1
2
3
=Record Length=
Smoothing :   ON
CH1  :        0.00V
CH2  :        0.00V
Main  :         10K
Zoom  :         4K
Mode  :  SINGLE
Type   :  EDGE CH1
Delay  :                102.3ns
Hold off  :         MINIMUM
CH3  :        0.00V
CH4  :        0.00V
BW   : 20MHz
=Trigger=
=Filter=
=Offset=
T
CD test 2->3 
upgrade
-1div
CH  Position  To
-3div
+1div
0div
+3div
CH3
 Position
  -
3
.00div
7
Disc motor output while in the 
test mode
11
12
DMO
SP+
SP-
Stopped
When there is no 
wound in the disk.
CH1=1V
2000/09/18   17:16:55
CH1
 V/DIV
    1V
500us/div
(500us/div)
CH1  V/DIV
CAL
Smoothing :   ON
BW   : 20MHz
CH1  :        0.00V
CH2  :        0.00V
Main  :         10K
Zoom  :         4K
CH3  :        0.00V
CH4  :        0.00V
Mode  :   AUTO
Type   :   EDGE CH1
Delay  :                102.3ns
Hold off  :         MINIMUM
=Filter=
=Offset=
=Record Length=
=Trigger=
VAR
NORM:2MS/s
T
T
1
DC   10:1
13
Normal tracking actuator drive
TR+
IC1 5pin, 6pin 
FO-
Disc playback
There is no 
wound in the 
disc.
Stopped
CH1=1V
2000/09/18   17:18:51
CH1
 V/DIV
    1V
1ms/div
(1ms/div)
CH1  V/DIV
CAL
Smoothing :   ON
BW   : 20MHz
CH1  :        0.00V
CH2  :        0.00V
Main  :         10K
Zoom  :         5K
CH3  :        0.00V
CH4  :        0.00V
Mode  :   AUTO
Type   :   EDGE CH1
Delay  :                102.3ns
Hold off  :         MINIMUM
=Filter=
=Offset=
=Record Length=
=Trigger=
VAR
NORM:1MS/s
T
T
1
DC   10:1
5
Normal focus actuator drive
4
IC1 3 pin
FO+
IC1 4 pin
IC1
5 pin-6 pin
When there is a 
wound in the disc.
Delay  :                102.3ns
Hold off  :         MINIMUM
T
T
Stopped
CH1=1V
2000/09/18   17:25:20
DC   10:1
1ms/div
(1ms/div)
NORM:1MS/s
1
=Record Length=
Smoothing :   ON
CH1  :        0.00V
CH2  :        0.00V
Main  :         10K
Zoom  :         5K
Mode  :   AUTO
Type   :   EDGE CH1
CH3  :        0.00V
CH4  :        0.00V
BW   : 20MHz
=Trigger=
=Filter=
0div
Trigger  Position  To
-4div
+4div
DELAY
Trigger  Knob
POSITION
=Offset=
Trigger
 Position
  -1.0
0
div
Actuator drive when damaged
13
TR+
IC1 5 pin
SD-CX1H
– 74 –
TROUBLESHOOTING
CD SECTION
      Parts code
1.
CD optical pickup Lens cleaner disc
UDSKA0004AFZZ
When the CD does not function
When the CD section does not operate when the objective lens of the optical pickup is dirty, this section may not operate. Clean
the objective lens, and check the playback operation. When this section does not operate even after the above step is taken, check
the following items.
Remove the cabinet and follow the trouble shooting instructions.
"Track skipping and/or no TOC (Table Of Contents) may be caused by build up of dust other foreign matter on the laser pickup
lens. Before attempting any adjustment make certain that the lens is clean. If not, clean it as mentioned below."
Turn off the power, and wipe the lens softly using a cleaning paper moistened with commercially available cleaning solution so
as not to damage it.
Be careful not to touch the lens with bare hands.
Dust gradually accumulates on the objective lens during use, and it may degrade performance.  To avoid this problem, use a
cleaning disc designed for CD optical pickup lenses.
HOW TO USE
CAUTION
Cleaning fluid
Cleaner disc
Using the brush in the cleaner cap, apply 1 or 2 drops of the cleaning fluid to the 
brush on the CD cleaner disc which has the mark next to it.
Place the CD cleaner disc onto the CD disc tray with the brush side down,then 
press the play button.
You will hear music for about 20 seconds and the CD player will automatically stop. 
If it continuous to turn, press the stop button.
1.
2.
3.
The CD lens cleaner should be effective for 30-50 operations, however if the 
brushes become worn out earlier then please the cleaner disc.
If the CD cleaner brushes become very wet then wipe off any excess fluid with a soft 
cloth.
Do not drink the cleaner fluid or allow it to come in contact with the eyes. In the 
event of this happening then drink and / or rinse with clean water and seek medical 
advice.
The CD cleaner disk must not be used on car CD players or on computer CD-ROM 
drives.
All rights reserved.Unauthorized duplicating, broadcasting and renting this product is 
prohibited by law.
– 75 –
SD-CX1H
Is 1.5V applied to the LDO terminal of pin 7 of IC2 ?
No
Yes
Is +1.8V applied to the collector of Q1 ?
Yes
No
IC2 is defective
Is +3.3V applied to C4 of R8 ?
The PWB pattern has been cut between Q1 and pin 8 of
CNS2.
No
Is +1.8V applied to pin 8 of CNS2 ?
R8 is defective.
No
Check the +3.3V stabilization circuit of IC1 and L2.
Yes
• The laser does not light up.
Yes
Is the laser lit in the CD test mode 1 ?
Yes
Does the unit switch from the CD test mode 1 to 2 ?
Refer to "Out of focus”.
Yes
When the CD test mode is changed from 2 to 3, does the disc
motor rotate properly ?
Yes
No
No
No
Refer to “HF is abnormal”.
No
Is sound output when the pickup lens is moved to where a track
is located by pressing the             (button) and            (button) in
the CD test mode5 ?
Yes
No
Yes
Check the power circuit in the main unit.
Refer to “The laser does not light up”.
Is the output at pin 19(HF) of IC2 flat in the CD test mode 4 ?
Does the sled motor run ?
Refer to “Track search is impossible”.
No
Are tracks played from the track 1 in ascending order by pressing
the             (button) ?
Refer to “The disc motor CLV servo is defective”.
Refer to “The sled motor
does not run”.
No
Refer to “No sound is heard”.
Yes
When the unit is turned off and on again, is it initialized ?
No
Has the optical pickup
returned to the inner
periphery position ?
Is the optical pickup in
switch in the OFF state ?
No
The optical pickup in-switch
is defective (ON state).
Yes
Check the
microcomputer
PWB.
ON
OFF
The optical
pickup in
switch is
defective.
Normal
Yes
The optical pickup is defective if CNS2 is normal.
Yes
Yes
When a disc is loaded, the power is turned on, and the CD (stop) button is pressed, is +7.2V applied to the collector of Q5 and +5.0V to the
emitter? Is +3.3V applied to pin 22 on IC1?
Is the voltage applied as shown in the wiring diagram ?
SD-CX1H
– 76 –
Does the pickup lens go up and down when removing the
disc ?
No
Yes
No
Refer to "The triangular wave for focus servo does not
appear".
Check the optical pickup wires. If OK, the optical pickup is
defective.
IC2 is defective.
Yes
• Out of focus.
Is the waveform inputted at pin 15 on IC2 when loading a
disc ?  <Refer to the waveform diagrams on page 72.>
Normal
No
Check between IC2 and CNS1. If OK, the optical pickup is
defective.
Check the parts around IC2. If OK, IC2 is defective.
Check the portion between IC1 and CNS2 and connection of the optical pickup wires. If OK, the optical pickup is defective.
Yes
• HF is abnormal.
Is tracking input found at pin 11 of IC2 ?
<Refer to the waveform diagrms on page 72.>
No
Check the parts around IC3. If OK, IC3 is defective.
Is the tracking output found at pin 34 on IC3 in the CD test
mode 4 ?
No
Check the parts around IC1. If OK, IC1 is defective.
Is there the output between pin 5 and 6 on IC1 ?
Yes
Yes
Is the output (tracking error signal) found at pin 4 and 5 on
IC2 in the CD test mode 3 ?
Abnormal
Yes
No
Refer to "The sled motor does not run".
IC2 is defective.
Check the portion between IC1 and CNS2 and connection of the optical pickup wires. If OK, the optical pickup is defective.
Check the portion between IC1 and CNS3, sires and periphery of the sled spin motor. If OK, the motor is defective.
Yes
• Track search is impossible.
Is the waveform outputted to pin 11 and 17 on IC2 when a
track is jumped ?
<Refer to the waveform diagrams on page 72.>
No
If the parts around IC1 are normal, IC is defective.
Is the wave form output found at pin34 and 40 on IC3 when a
track is jumped ?
<Refer to the waveform diagrams on page 73.>
No
If the parts around IC1 are normal, IC is defective.
Is the slide output found at pin25 and 26 on IC1, and the
tracking output at pin5 and 26 ?
Yes
Yes
Does the sled motor run by pressing the          /          button
in the test mode ?
No
Page of 34