– 37 –
CD-MD3000H/CD-MD3000W
Test mode setting method
1. "MD TEST 1" ENTER.
(State  A  is changed to state  B .)
2. Insert the playback-only disc 1 (high reflection disc) or the recordable disc 2 (low reflection disc). (State is changed to C.)
 A  tsm 1C
e
: TEST MODE
 represents version of MD microcomputer.
            STOP state
 B  EJECT
 C  AUT AJST
2. 
Test Mode
Entering the specific mode
Whenever the EQUALIZER button is pressed, the mode is changed.
Cancel of test mode
To restore the usual state once reset.
*Before pressing the MENU button, be sure to perform the AUTO preliminary adjustment and the AUTO adjustment. Make sure
that they return a "COMPLETE" result.
*When the data of EEPROM was changed or the preliminary adjustment was performed again, be sure to press the MENU button
to write data in the EEPROM.
(Data is written in the EEPROM by pressing the MENU button.)
*When changing the EEPROM settings, write them into the EEPROM and then enter the test mode again. Perform the AUTO
preliminary adjustment and the AUTO adjustment. Then, write those into the EEPROM.
• Test Mode
1. EJECT mode
• TEMP setting (of EEPROM setting)
• CONTROL setting (of EEPROM setting)
• Setting of laser power (record/playback power)
2. AUTO pre-adjustment mode
• Automatic pre-adjustment is performed.
3. AUTO adjustment mode
• Automatic adjustment is performed. (After adjustment the grating adjustment mode is set.)
• RESULT sub-mode
• Therefore do not set this mode since it is not necessary for the service.
• RESULT mode (final adjustment)
• MANUAL pre-adjustment mode
• MANUAL adjustment mode
• MANUAL AFB adjustment mode
• ERROR DATA
4. EEPROM setting mode
• Various coefficients of digital servo are changed manually.
5. TEST-PLAY mode
• Continuous playback from the specified address is performed.
• C1 error rate measurement, ADIP error rate measurement.
6. TEST-REC mode
• Continuous recording from the specified address is performed.
7. INNER mode
• The position where the INNER switch is turned on is measured.
(When the MD STOP button is pressed in the   C  state, the indication  A  is
restored. To restore   C  again, press the EQUALIZER button.)
1. EJECT mode
Step 1
Test mode EJECT state
[ _ _ E J E C T _ _ _ ]
Step 2
Press the DISP/CHARACTER button. Playback power output state
[ p p w _ _ _ _ _ _ _ ]
Step 3
Press the DISP/CHARACTER button. Rec power output state
[ r p w _ _ _ _ _ _ _ ]
Step 4
Press the DISP/CHARACTER button. Therefore do not set this mode since it is not necessary
[ x p w _ _ _ _ _ _ _ ]
for the service.
Step 5
Press the X-BASS button.
TEMP setting of EEPROM setting
[TEMP _ 
 _ 
 ]
Step 6
Press the PLAY button.
CONTROL setting of EEPROM setting
Step No.
Setting Method
Remarks
Display
MD TEST
Playback power output
[ppw]
DC0.2V
DC1.5V
To check 2
NG
Microcomputer may have recognized the PWB 
as for playback-only. Perform check 1.
Recording power output
[rpw]
Cannot enter 
[rpw] mode
DC1.8V
Below DC1.5V
Check end
NG
NG
Perform check 2.
Microcomputer may have recognized the PWB 
as for playback-only. Perform check 1.
Step
Mode
Check items
Pin 3 of IC1401
Result
Probable cause and remedy
1
2
A U T O   Y O B I
AUTO AJST
R S T   Y O B I
A U T   A F B
EEPROM_SET
MAN AFB
M N U   Y O B I
  M N U   A J S T
ERR DATA
(ERRER DATA)
(AUTO prelimirary adjustment) 
(AUTO adjustment)
(Advanced FAB adjustment)
(RESULT 
Y O B I )
RESULT  
(MANUAL pre-adjustment)
 (MANUAL adjustment) 
(MANUAL advanced FAB adjustment) 
(EEPROM setting)
CD-MD3000H/CD-MD3000W
– 38 –
3. AUTO adjustment mode
Step No.
Setting Method
Remarks
Display
Step 1
Test mode STOP state
The AUTO preliminary adjustment should have been completed.
[ t s m       
 e 
 ]
Step 2
Press once the EQUALIZER button.
AUTO adjustment menu
[ A U T O _ A J S T _ ]
Step 3
Press  once the TAPE REC button.
The slide moves to the innermost periphery, and automatic
 : _ _ _ _ _ _ ]
adjustment is started.
• In case of high reflection disc 
 changes as follows.
PEG
HAG
• In case of low reflection disc 
 changes as follows.
PEG
LAG
End of adjustment
If adjustment is OK, Step 4.
If adjustment is NG, Step 8.
Step 4
Adjustment value output
For grating adjustment
[ _ C O M P L E T E _ ]
Press the TAPE REC  button.
STEP 5
Press the MD STOP button.
STEP 2   AUTO adjustment
Step 5
Continuous playback (pit section) Confirmation of CI error
[ s
c
 ]
Continuous playback (groove section)
[ a
c
 ]
Step 6
Press the DISP/CHARACTER button. Conformation of ADIP error (High reflection disc STEP 7)
[ a
a
 ]
Press the MD STOP button.
STEP 2  AUTO adjustment menu
Step 7
Continuous playback (pit section) Confirmation of Jitter
[ s
 j 
 ]
Continuous playback (groove section)
[ a
 j 
 ]
Step 8
Adjustment value output
[  C a n ' t  _  A D J .  ]
Press the MD STOP button.
STEP 2  AUTO adjustment menu
• 
 : Adjustment name,  
 : Measurement value,  
 : Address
2. AUTO pre-adjustment mode (Low reflection disc only)
Step No.
Setting Method
Display
Step 1
Test mode STOP state
[ t s m       
 e 
 ]
Step 2
Press once the EQUALIZER button. AUTO adjustment menu
[ A U T O _ A J S T _ ]
Step 3
Press once the REV PLAY button.
AUTO pre-adjustment menu
[ _ A U T _ Y O B I _ ]
Step 4
Press  once the TAPE REC button.
• During automatic adjustment 
 changes as follows.
 : _ _ _ _ _ _ ]
HAo
→ 
• 
 
• 
 
• 
 
• 
 
• 
 
• 
 
• 
 
• 
 
 →
LAO
End of adjustment
If adjustment is OK, Step 5.
If adjustment is NG, Step 6.
Step 5
Grating adjustment,
[ _ C O M P L E T E _ ]
adjustment value output
Press once the MD STOP button.
STEP 3  AUTO pre-adjustment menu
Step 6
Adjustment value output
[  C a n ' t  _  A D J .  ]
Press once the MD STOP button.
STEP 3  AUTO pre-adjustment menu
• 
 : Adjustment name
Remarks
Confirmation of pickup laser power
It is possible to confirm in the record/playback mode with the aid of laser power meter.  However, since the laser power meter
measurement is characterized with dispersion, obtained data are used only for confirmation.
     Reference data (at room temperature 25
°
C)
     Playback: 0.72
±
0.1 mW
     Record: 5.5
±
0.5 mW
Note: Never see directly the laser light.  Otherwise your eyes are injured.
With the pre-adjustment disc (MMD-318)
If "R/P WHICH?" appears, the mechanism and the PWB can be mismatched. Check whether the combination of the playing/
recording PWB and mechanism are appropriate.
If "R/P WHICH?" still appears, eject the disc and check as follows.
Check 1: Check the pin 100 line of IC1401 for defective soldering. Check the pin 93 line of IC1401 for short-circuit and defective
           soldering (Also check the SW PWB).
Check 2: Check the pin 3 line of IC1401 for defective soldering and short-circuit with other patterns. Check that the pickup laser
is not broken.
4. AUTO AFB adjustment mode (Low reflection disc only)
Step No.
Setting Method
Remarks
Display
Step 1
Test mode STOP state
The AUTO preliminary adjustment should have been completed.
[ t s m       
 e 
 ]
Step 2
Press the EQUALIZER button two times.
AUTO FAB adjustment menu
[ _ A U T  _ A F B _ _ ]
Step 3
Press  the TAPE REC button.
The slide moves to the innermost periphery, and automatic
[F A B 
 _
 ]
"PB_DISC_ _ _ " (HIGH reflection DISC)
Step 4
Adjustment value output
STEP 2   AUTO adjustment
[
 _ 
 _ _ _]
Press the MD STOP button.
• 
 , 
 , 
 : Measurement value
– 39 –
CD-MD3000H/CD-MD3000W
5. EEPROM setting mode
A) Focus setting
Step No.
Setting Method
Display
Step 1
Test mode STOP state
[ t s m       
 e 
 ]
Step 2
Press the EQUALIZER button eight times. [ E E P R O M_ S E T ]
Step 3
Press the TAPE REC button.
[ _ _ F o c u s _ _ _ ]
Step 4
Press the TAPE REC button.
[F G _ _ _ _ _ _ 
]
Step 5
Press the EQUALIZER button.
[F F 0 _ _ _ _ _ 
]
Step 6
Press the EQUALIZER button.
[F F 1 _ _ _ _ _ 
]
Step 7
Press the EQUALIZER button.
[F F 2 _ _ _ _ _ 
]
Step 8
Press the EQUALIZER button.
[F Z H L E V _ _ 
]
Step 9
Press the EQUALIZER button.
[F O K L E V h _ 
]
Step 10
Press the EQUALIZER button.
[F O K L E V L _ 
]
Step 11
Press the EQUALIZER button.
[F O S T n _ _ _ 
]
Step 12
Press the EQUALIZER button.
[D S C J G _ _ _ 
]
• 
 : Setting value
B) Spin setting
Step 1
Test mode STOP state
[ t s m       
 e 
 ]
Step 2
Press the EQUALIZER button eight times. [ E E P R O M_ S E T ]
Step 3
Press the TAPE REC button.
[ _ _ F o c u s _ _ _ ]
Step 4
Press the EQUALIZER button.
[ _ S p i n d l e _ _ ]
Step 5
Press the TAPE REC button.
[S P G _ _ _ _ _ 
]
Step 6
Press the EQUALIZER button.
[S P G _ i n _ _ 
]
Step 7
Press the EQUALIZER button.
[S P G _ m i d _ 
]
Step 8
Press the EQUALIZER button.
[S P G _ o u t _ 
]
Step 9
Press the EQUALIZER button.
[S P 1 _ _ _ _ _ 
]
Step 10
Press the EQUALIZER button.
[S P 2 _ _ _ _ _ 
]
Step 11
Press the EQUALIZER button.
[S P 3 _ _ _ _ _ 
]
Step 12
Press the EQUALIZER button.
[S P 4 _ _ _ _ _ 
]
Step 13
Press the EQUALIZER button.
[S P 5 _ _ _ _ _ 
]
Step 14
Press the EQUALIZER button.
[S P D L  I M _ _ 
]
Step 15
Press the EQUALIZER button.
[S P K L E V m _ 
]
• 
 : Setting value
C) Tracking setting
Step No.
Setting Method
Display
Step 1
Test mode STOP state
[ t s m       
 e 
 ]
Step 2
Press the EQUALIZER button eight times. [ E E P R O M_ S E T ]
Step 3
Press the TAPE REC button.
[ _ _ F o c u s _ _ _ ]
Step 4
Press the EQUALIZER button two times.
[ _ T r a c k i n g _ ]
Step 5
Press the TAPE REC button.
[T G _ _ _ _ _ _ 
]
Step 6
Press the EQUALIZER button.
[T F 0 _ _ _ _ _ 
]
Step 7
Press the EQUALIZER button.
[T F 1 _ _ _ _ _ 
]
Step 8
Press the EQUALIZER button.
[T F 2 _ _ _ _ _ 
]
Step 9
Press the EQUALIZER button.
[F T 3 _ _ _ _ _ 
]
Step 10
Press the EQUALIZER button.
[S V C N T 4 _ _ 
]
Step 11
Press the EQUALIZER button.
[T R B L V o _ _ 
]
Step 12
Press the EQUALIZER button
[T R B L V t _ _ 
]
Step 13
Press the EQUALIZER button
[T R K L V o _ _ 
]
Step 14
Press the EQUALIZER button
[T R K L V t _ _ 
]
Step 15
Press the EQUALIZER button
[T D P W o _ _ _ 
]
Step 16
Press the EQUALIZER button
[T D P W t _ _ _ 
]
Step 17
Press the EQUALIZER button
[S L C T o _ _ _ 
]
Step 18
Press the EQUALIZER button
[S L C T t _ _ _ 
]
Step No.
Setting Method
Display
CD-MD3000H/CD-MD3000W
– 40 –
C) Tracking setting
Step No.
Setting Method
Display
Step 19
Press  the EQUALIZER button.
[S L C T m _ _ _ 
]
Step 20
Press  the EQUALIZER button.
[T C R S C 1 P _ 
]
Step 21
Press  the EQUALIZER button.
[T C R S C 0 h _ 
]
Step 22
Press  the EQUALIZER button.
[T C R S C 0 L _ 
]
Step 23
Press  the EQUALIZER button.
[T C R S C H h _ 
]
Step 24
Press  the EQUALIZER button.
[T C R S C H L _ 
]
Step 25
Press  the EQUALIZER button.
[C O T L V p _ _ 
]
Step 26
Press  the EQUALIZER button.
[C O T L V  r _ _ 
]
Step 27
Press  the EQUALIZER button.
[J  P  i  n  t _ _ _ 
]
Step 28
Press  the EQUALIZER button.
[K I K 1  0 _ _ _ 
]
• 
 : Setting value
D) Sled setting
Step No.
Setting Method
Display
Step 1
Test mode STOP state
[ t s m       
 e 
 ]
Step 2
Press the EQUALIZER button eight times. [ E E P R O M_ S E T ]
Step 3
Press the TAPE REC button.
[ _ _ F o c u s _ _ _ ]
Step 4
Press the EQUALIZER button three times. [ _ _ _ S l e d _ _ _ ]
Step 5
Press the TAPE REC button.
[S L G _ _ _ _ _ 
]
Step 6
Press the EQUALIZER button.
[S L 2 _ _ _ _ _ 
]
Step 7
Press the EQUALIZER button.
[S L D L I M _ _ 
]
Step 8
Press the EQUALIZER button.
[S L D L E V _ _ 
]
Step 9
Press the EQUALIZER button.
[S L K L V k _ _ 
]
Step 10
Press the EQUALIZER button.
[S L K L V t _ _ 
]
Step 11
Press the EQUALIZER button.
[S L K L V m _ _ 
]
Step 12
Press the EQUALIZER button.
[S L B K M _ _ _ 
]
Step 13
Press the EQUALIZER button.
[S L K  r  i  o _ _ 
]
Step 14
Press the EQUALIZER button.
[S L K  r  o  i  _ _ 
]
Step 15
Press the EQUALIZER button.
[S L K  l  i  o _ _ 
]
Step 16
Press the EQUALIZER button.
[S L K  l  o  i _ _ 
]
• 
 : Setting value
E) TEMP setting
Step No.
Setting Method
Display
Step 1
EJECT state
[ _ _ E J E C T _ _ _  ]
Step 2
Press the X-BASS button.
[ T E M P_ 
 _ 
 ]
• 
 : Setting value, 
 : Measurement value
F) CONTROL setting
Step No.
Setting Method
Display
Step 1
Test mode STOP state
[ t s m       
 e 
 ]
Step 2
Press the EQUALIZER button eight times. [ E E P R O M_ S E T ]
Step 3
Press the TAPE REC button.
[ _ _ F o c u s _ _ _ ]
Step 4
Press the EQUALIZER button five times.
[ _ C o n t r o l _ _ ]
Step 5
Press the TAPE REC button.
[C O N T R L 1 _ 
]
Step 6
Press the EQUALIZER button.
[C O N T R L 2 _ 
]
Step 7
Press the EQUALIZER button.
[A D J T T M _ _ 
]
Step 8
Press the EQUALIZER button.
[H D E Q A D _ _ 
]
Step 9
Press the EQUALIZER button.
[L D E Q A D _ _ 
]
Step 10
Press the EQUALIZER button.
[G D E Q A D _ _ 
]
Step 11
Press the EQUALIZER button.
[H D E Q B C _ _ 
]
Step 12
Press the EQUALIZER button.
[L D E Q B C _ _ 
]
Step 13
Press the EQUALIZER button.
[G D E Q B C _ _ 
]
Step 14
Press the EQUALIZER button.
[H A L S G _ _ _ 
]
Step 15
Press the EQUALIZER button.
[L A L S G _ _ _ 
]
Page of 127
Display

Click on the first or last page to see other CD-MD3000 (serv.man10) service manuals if exist.