DOWNLOAD Sharp AN-PR1100H Service Manual ↓ Size: 14.32 MB | Pages: 108 in PDF or view online for FREE

Model
AN-PR1100H
Pages
108
Size
14.32 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / Home Theatre
File
an-pr1100h.pdf
Date

Sharp AN-PR1100H Service Manual ▷ View online

AN-PR1100H
2 – 3
[4] EEPROM List (Version: 02) (1/2)
HEX
ITEM
CODE
ITEM
CODE
HEX
ITEM
CODE
ITEM
CODE
025A
602
PVER
02h
AUMD
#REF!
07h
02B2
690
GPDO3
B6h
48
9Dh
025C
604
ITVL
25h
ITVC
01h
02B4
692
GPDFH
05h
50
0Ch
025E
606
NBCF
05h
NBLV
65h
02B6
694
GPDF3
33h
52
5Dh
0260
608
INISW
FFh
CHECK-SUM
67h
02B8
696
GADOH
14h
54
18h
0262
610
reserved
FFh
reserved
FFh
02BA
698
GADO3
57h
56
E9h
0264
612
reserved
FFh
reserved
FFh
02BC
700
GADFH
0Fh
58
F6h
0266
614
CHECK-SUM
03h
OFGA
00h
02BE
702
GADF3
4Ch
60
16h
0268
616
OFBS
00h
OFTR
00h
02C0
704
GDDOH
08h
62
00h
026A
618
reserved
FFh
CIGA
02h
02C2
706
GDDO3
00h
64
00h
026C
620
CIBS
00h
CITR
03h
02C4
708
GDDFH
0Bh
66
4Ch
026E
622
reserved
FFh
ANGA
00h
02C6
710
GDDF3
E0h
68
7Bh
0270
624
ANBS
0Bh
ANTR
05h
02C8
712
GCDOH
09h
70
82h
0272
626
reserved
FFh
SOGA
02h
02CA
714
GCDO3
0Dh
72
74h
0274
628
SOBS
00h
SOTR
03h
02CC
716
GCDFH
0Bh
74
4Ch
0276
630
reserved
FFh
SPGA
02h
02CE
718
GCDF3
E0h
80
7Bh
0278
632
SPBS
00h
SPTR
03h
02D0
720
GaDOH
14h
82
18h
027A
634
reserved
FFh
LAGA
02h
02D2
722
GaDO3
57h
84
E9h
027C
636
LABS
00h
LATR
03h
02D4
724
GaDFH
07h
86
21h
027E
638
reserved
FFh
reserved
FFh
02D6
726
GaDF3
48h
88
2Bh
0280
640
CHECK-SUM
E2h
E48AU
3Ch
02D8
728
reserved
2Bh
90
9Ah
0282
642
E48AM
39h
E48AL
83h
02DA
730
0
FFh
92
FF
0284
644
E48BU
A0h
E48BM
A3h
02DC
732
2
9Ah
94
FF
0286
646
E48BL
60h
E48CU
29h
02DE
734
4
FFh
96
FF
0288
648
E48CM
EBh
E48CL
F2h
02E0
736
6
FF
98
FF
028A
650
E48DU
5Fh
E48DM
5Ch
02E2
738
8
FF
100
FF
028C
652
E48DL
9Fh
E48EU
D9h
02E4
740
10
FF
102
FF
028E
654
E48EM
DAh
E48EL
8Ah
02E6
742
12
FF
104
FF
0290
656
E44AU
3Bh
E44AM
F9h
02E8
744
14
FF
106
FF
0292
658
E44AL
E1h
E44BU
A3h
02EA
746
16
FFh
108
FFh
0294
660
E44BM
71h
E44BL
6Dh
02EC
748
18
FFh
110
FFh
0296
662
E44CU
28h
E44CM
77h
02EE
750
20
FFh
112
FFh
0298
664
E44CL
D4h
E44DU
5Ch
02F0
752
22
FFh
114
FFh
029A
666
E44DM
8Eh
E44DL
93h
02F2
754
24
FFh
116
FFh
029C
668
E44EU
DBh
E44EM
8Eh
02F4
756
26
FFh
118
FFh
029E
670
E44EL
49h
E32AU
3Ah
02F6
758
28
FFh
120
FFh
02A0
672
E32AM
F6h
E32AL
2Eh
02F8
760
30
FFh
122
FFh
02A2
674
E32BU
B0h
E32BM
47h
02FA
762
32
FFh
124
FFh
02A4
676
E32BL
CFh
E32CU
22h
02FC
764
34
FFh
126
FFh
02A6
678
E32CM
89h
E32CL
1Bh
02FE
766
36
FFh
128
FFh
02A8
680
E32DU
4Fh
E32DM
B8h
0300
768
38
FFh
130
FFh
02AA
682
E32DL
30h
E32EU
E2h
0302
770
40
FFh
132
FFh
02AC
684
E32EM
80h
E32EL
E6h
0304
772
42
FFh
134
FFh
02AE
686
reserved
FFh
CHECK-SUM
27h
0306
774
44
FFh
136
FFh
02B0
688
GPDOU
0Fh
GPDO2
11h
0308
776
46
FFh
138
FFh
HEX
ITEM
CODE
ITEM
CODE
HEX
ITEM
CODE
ITEM
CODE
030A
778
RM32
FFh
RM33
FFh
0332
818
RM72
FFh
RM73
FFh
030C
780
RM34
FFh
RM35
FFh
0334
820
RM74
FFh
RM75
FFh
030E
782
RM36
FFh
RM37
FFh
0336
822
RM76
FFh
RM77
FFh
0310
784
RM38
FFh
RM39
FFh
0338
824
RM78
FFh
RM79
FFh
0312
786
RM40
FFh
RM41
FFh
033A
826
RM80
FFh
RM81
FFh
0314
788
RM42
FFh
RM43
FFh
033C
828
RM82
FFh
RM83
FFh
0316
790
RM44
FFh
RM45
FFh
033E
830
RM84
FFh
RM85
FFh
0318
792
RM46
FFh
RM47
FFh
0340
832
RM86
FFh
RM87
FFh
031A
794
RM48
FFh
RM49
FFh
0342
834
RM88
FFh
RM89
FFh
031C
796
RM50
FFh
RM51
FFh
0344
836
RM90
FFh
RM91
FFh
031E
798
RM52
FFh
RM53
FFh
0346
838
RM92
FFh
RM93
FFh
0320
800
RM54
FFh
RM55
FFh
0348
840
RM94
FFh
RM95
FFh
0322
802
RM56
FFh
RM57
FFh
034A
842
RM96
FFh
RM97
FFh
0324
804
RM58
FFh
RM59
FFh
034C
844
RM98
FFh
RM99
FFh
0326
806
RM60
FFh
RM61
FFh
034E
846
RM100
FFh
RM101
FFh
0328
808
RM62
FFh
RM63
FFh
0350
848
RM102
FFh
RM103
FFh
032A
810
RM64
FFh
RM65
FFh
0352
850
RM104
FFh
RM105
FFh
032C
812
RM66
FFh
RM67
FFh
0354
852
RM106
FFh
RM107
FFh
032E
814
RM68
FFh
RM69
FFh
0356
854
RM108
FFh
RM109
FFh
0330
816
RM70
FFh
RM71
FFh
0358
856
RM110
FFh
CHECK-SUM
EFh
㧗㧜㧜㧴
㧗㧜㧜㧴
㧗㧜㧝㧴
㧗㧜㧝㧴
㧗㧜㧜㧴
㧗㧜㧜㧴
㧗㧜㧝㧴
㧗㧜㧝㧴
ADDRESS
㧗㧜㧜㧴
㧗㧜㧜㧴
ADDRESS
㧗㧜㧜㧴
㧗㧜㧜㧴
㧗㧜㧝㧴
㧗㧜㧝㧴
ADDRESS
㧗㧜㧝㧴
㧗㧜㧝㧴
ADDRESS
AN-PR1100H
2 – 4
[4] EEPROM List (Version: 02) (2/2)
NOTES:
(1) Use an attached HEX format file for setup of data to EEPROM writer.
(2) EEPROM currently used for this model is made in CATALYST. It is CAT24WC05YI.
HEX
ITEM
CODE
ITEM
CODE
HEX
ITEM
CODE
ITEM
CODE
035A
858
RM56
FFh
RM57
FFh
0382
898
RM96
FFh
RM97
FFh
035C
860
RM58
FFh
RM59
FFh
0384
900
RM98
FFh
RM99
FFh
035E
862
RM60
FFh
RM61
FFh
0386
902
RM100
FFh
RM101
FFh
0360
864
RM62
FFh
RM63
FFh
0388
904
RM102
FFh
RM103
FFh
0362
866
RM64
FFh
RM65
FFh
038A
906
RM104
FFh
RM105
FFh
0364
868
RM66
FFh
RM67
FFh
038C
908
RM106
FFh
RM107
FFh
0366
870
RM68
FFh
RM69
FFh
038E
910
RM108
FFh
RM109
FFh
0368
872
RM70
FFh
RM71
FFh
0390
912
RM110
FFh
RM111
FFh
036A
874
RM72
FFh
RM73
FFh
0392
914
RM112
FFh
RM113
FFh
036C
876
RM74
FFh
RM75
FFh
0394
916
RM114
FFh
RM115
FFh
036E
878
RM76
FFh
RM77
FFh
0396
918
RM116
FFh
RM117
FFh
0370
880
RM78
FFh
RM79
FFh
0398
920
RM118
FFh
RM119
FFh
0372
882
RM80
FFh
RM81
FFh
039A
922
RM120
FFh
RM121
FFh
0374
884
RM82
FFh
RM83
FFh
039C
924
RM122
FFh
RM123
FFh
0376
886
RM84
FFh
RM85
FFh
039E
926
RM124
FFh
RM125
FFh
0378
888
RM86
FFh
RM87
FFh
03A0
928
RM126
FFh
RM127
FFh
037A
890
RM88
FFh
RM89
FFh
03A2
930
RM128
FFh
RM129
FFh
037C
892
RM90
FFh
RM91
FFh
03A4
932
RM130
FFh
RM131
FFh
037E
894
RM92
FFh
RM93
FFh
03A6
934
RM132
FFh
RM133
FFh
0380
896
RM94
FFh
RM95
FFh
03A8
936
RM134
FFh
0
0
HEX
ITEM
CODE
ITEM
CODE
HEX
ITEM
CODE
ITEM
CODE
03AA
938
RM80
FFh
RM81
FFh
03D2
978
RM120
FFh
RM121
FFh
03AC
940
RM82
FFh
RM83
FFh
03D4
980
RM122
FFh
RM123
FFh
03AE
942
RM84
FFh
RM85
FFh
03D6
982
RM124
FFh
RM125
FFh
03B0
944
RM86
FFh
RM87
FFh
03D8
984
RM126
FFh
RM127
FFh
03B2
946
RM88
FFh
RM89
FFh
03DA
986
RM128
FFh
RM129
FFh
03B4
948
RM90
FFh
RM91
FFh
03DC
988
RM130
FFh
RM131
FFh
03B6
950
RM92
FFh
RM93
FFh
03DE
990
RM132
FFh
RM133
FFh
03B8
952
RM94
FFh
RM95
FFh
03E0
992
RM134
FFh
RM135
FFh
03BA
954
RM96
FFh
RM97
FFh
03E2
994
RM136
FFh
RM137
FFh
03BC
956
RM98
FFh
RM99
FFh
03E4
996
RM138
FFh
RM139
FFh
03BE
958
RM100
FFh
RM101
FFh
03E6
998
RM140
FFh
RM141
FFh
03C0
960
RM102
FFh
RM103
FFh
03E8
1000
RM142
FFh
RM143
FFh
03C2
962
RM104
FFh
RM105
FFh
03EA 1002
RM144
FFh
RM145
FFh
03C4
964
RM106
FFh
RM107
FFh
03EC
1004
RM146
FFh
RM147
FFh
03C6
966
RM108
FFh
RM109
FFh
03EE
1006
RM148
FFh
RM149
FFh
03C8
968
RM110
FFh
RM111
FFh
03F0
1008
RM150
FFh
RM151
FFh
03CA
970
RM112
FFh
RM113
FFh
03F2
1010
RM152
FFh
RM153
FFh
03CC
972
RM114
FFh
RM115
FFh
03F4
1012
RM154
FFh
RM155
FFh
03CE
974
RM116
FFh
RM117
FFh
03F6
1014
RM156
FFh
RM157
FFh
03D0
976
RM118
FFh
RM119
FFh
03F8
1016
RM158
FFh
0
0
HEX
ITEM
CODE
ITEM
CODE
03FA
1018
RM104
FFh
RM105
FFh
03FC
1020
RM106
FFh
RM107
FFh
03FE
1022
RM108
FFh
RM109
FFh
㧗㧜㧝㧴
㧗㧜㧝㧴
ADDRESS
㧗㧜㧜㧴
㧗㧜㧜㧴
㧗㧜㧝㧴
㧗㧜㧝㧴
ADDRESS
㧗㧜㧜㧴
㧗㧜㧜㧴
㧗㧜㧝㧴
㧗㧜㧝㧴
ADDRESS
㧗㧜㧜㧴
㧗㧜㧜㧴
㧗㧜㧝㧴
㧗㧜㧝㧴
ADDRESS
㧗㧜㧜㧴
㧗㧜㧜㧴
㧗㧜㧝㧴
㧗㧜㧝㧴
㧗㧜㧜㧴
㧗㧜㧜㧴
ADDRESS
AN-PR1100H
2 – 5
[5] KEY / LED Check Mode
Display of 7-segment LED and each single LED
Transition during start-up 
Press POWER key to return to Test Mode route state.
[6] Quick Volume Change Mode
Purpose
The purpose of this mode is inspection time shortening in the 
production.
This mode is the same as the USER MODE except for the volume 
operation.
Volume operation in this mode becomes a change in a step only to 
the necessary position in inspection process.
The specification of operation
Main volume operation at QUICK VOL CHANGE MODE
Only the following position of volume can be set up in this mode. 
 
NOTES:
(1) About operation specification of  "VOL +/– key".
(2) A difference from this mode and the user mode is only a possible
volume steps and initial value after the mode start.
ANXXXX*H
KEY TEST
Test mode route state
(Input select key)
**
Using FUNCTION key select “KEY TEST”
Press Volume (–) / (+) key to enter KEY TEST
Press key according to below check key 
response or LED light-up table
KEY
FL DISPLAY
FUNCTION + VOLUME (–)
FL all light-up 
LED light-up
FUNCTION
KEY 1-1
VOLUME +
KEY 1-2
VOLUME –
KEY 1-3
VOLUME 0
VOLUME 1
↑  ↓
(VOL+)
(VOL–)
VOLUME 10
↑  ↓
(VOL+)
(VOL–)
VOLUME 30
↑  ↓
(VOL+)
(VOL–)
VOLUME 40
↑  ↓
(VOL+)
(VOL–)
VOLUME 20
↑  ↓
(VOL+)
(VOL–)
(default value at QUICK VOL CHANGE MODE start)
AN-PR1100H
2 – 6
[7] Tuner Test Mode
Outline
This Test Mode control are same with Normal Power-ON, only 
Power-ON in TUNER function.
After Power-ON the operation and display are same but the TUNER 
preset already memory as table below.
TEST Mode Operation
Set will Power-ON same process like user Power-ON, but direct to 
TUNER Function Preset No. 1 of table below. 
Set Preset Memory will be set as below table.
Key operation after Power ON are same with User Power-ON.
* When Test Mode end, Tuner Preset Memory will be initialize. 
Others Memory initialize is not neccesry.
[8] ASPM Test Mode (For EU Destination)
Outline
At Tuner RDS ASPM operation need to be confirm for EU(H) model 
only.
Power-ON in TUNER function, and scanning frequency from 
105.00MHz - 108.00MHz.
And RDS station Preset Memory maximum 3 station.
TEST Mode Operation
Power ON in TUNER Function 106.50MHz FM Stereo Band. At 
same time Only Preset No. ch1 - ch3 leave blank and all ch4 - ch40 
memory at 87.50MHz FM Stereo Band.
With the press of ASPM key, ASPM operation will start at 
105.00MHz frequency.
If RDS station received Preset will memory from ch1. (There is no 
need to  memory PS name in ASPM Test Mode. If preset change 
during Test Mode Frequency will be display first)
Scan will stop after reach frequency 108.00MHz, and return to 
frequency 106.50MHz FM Stereo.
To confirm Memory content display will show Preset Number and 
frequency for ch1until ch3. After display are confirmed frequency will 
return to 106.50MHz FM STEREO. (Display method same with 
Tuner display during Normal POWER ON.)
If ASPM key is press again, ASPM operation will start from 2 untill 
5.
While scanning if 3 station memorized, Scanning will stop and 
operation 4 and 5 will take place.
Afterward, even if ASPM key input detect ASPM operation will not 
be execute. "__END__" displayed and operation canceled. 
Additional
Other then above, operation for ASPM are same with User 
operation. So, when 1st time scan with same PI code Station with 
most strong signal will be memory and will not be memory many 
time. For 2nd and more station with same frequency will not be 
memory.
But, if different station with same PI code (same PI with different 
frequency station), station one with most strong signal will be 
memory.
So, station that already memorized before scan will be ignore. 
Therefore, even station with same same PI code after 3 times ASPM 
scan, It is possible that, 3 station will be memorized in Signal Strong 
order. 
After Test Mode end only Tuner preset memory will be reset and set 
to default. Ohers Memory, no need to be initialize.
50K/9K
EU
㧔H㧕
Destination
P1
87.50M
P
reset Memory N
o.
SPAN
106.00M
P4
98.00M
P5
108.00M
P2
90.00M
P3
Page of 108