Sharp AE-A184 Service Manual / Specification ▷ View online
9
AY-A184E
AY-A244E
AE-A184E
AE-A244E
AY-A244E
AE-A184E
AE-A244E
Figure
L-3.
Electronic
Control
Circuit
Diagram
for
AY-A244E
C21
0.01µF 250V
NR2 471K
T1
T2
6
4
L
TR1AC
BCR5PM-12L-A8
N
C.T.
FUSE
2.5A
250V
B
BLUE
NR1 471K
C1
QXW2E104K
R1
390
1W
1
3
5
C
A
FAN MOTOR
THERMAL PROTECTOR
FAN MOTOR
CAPACITOR
BLUE
GRAY
CN1
S21ME3F
PT
0.1
250VAC
THERMAL FUSE
D1
D4
D3
D2
R2
22K
R3
22K
N
1
2
3
D
E
TRANSFORMER
BLUE
RY1
RY2
RY3
BLACK
BROWN
PURPLE
ORANGE
CNR1
CNR2
6
5
6
5
C3
0.22µF
50V
C2
2200µF
35V
C4
47µF
25V
IC 2
IC 3
IN
OUT
IN
OUT
GND
0.1µ 50V
C6
100µF
10V
12V
BCN2
CN2
C5
5V
C16
0.1µF
50V
NC
C20 0.01µF
1
2
3
4
8
7
6
5
X24C01P
R4
3.3K
R31
10K
1SR35-100A x 4
JP5
JP6
JP7
JP8
JP9
JP10
JP11
COOL WIND
RECEIVER UNIT
FAN PULS
DEICE A
DEICE B
SWEAT
COMP OFF
TIME
1
P20
64
AV
REF
2
P21
63
AV
DD
3
P22
62
AN17
4
P23
61
AN16
5
P24
60
AN15
6
P25
59
AN14
7
P26
58
AN13
8
P27
57
AN12
9
P30
56
AN11
10
P31
55
AN10
11
P32
54
AV
SS
12
P33
53
P04
13
P34
52
XT2
14
P35
51
IC
15
BUZ
50
X1
16
P37
49
X2
17
V
SS
48
V
DD
18
P40
47
P03
19
P41
46
INTP2
20
P42
45
INTP1
21
P43
44
INTP0
22
P44
43
/RESET
23
P45
42
P67
24
P46
41
P66
25
P47
40
P65
26
P50
39
P64
27
P51
38
P63
28
P52
37
P62
29
P53
36
P61
30
P54
35
P60
31
P55
34
P57
32
V
SS
33
P56
µPD78012
3
2
1
3
2
1
SW1 02
SW1 01
TEST RUN
AUX
5V
CN101
BCN1
5V
POWER ON JP1
MEMORY JP2
DEBAG A JP3
DEBAG B JP4
C19
0.22µF
50V
2
4
3
5
1
RCM1
10K
10K
-1000pF x 2
RA1
10K
x 4
12V
RY1
1
2
3
4
5
CN3
LOUVER
MOTOR
PT
S21ME3F
R5
2.7K
BZ
IC 6(OPTION)
IC 4
4
7
4
7
9
1
7
6
5
4
3
2
16
10
11
12
13
14
15
C15
0.22µF
50V
1
2
1
2
D5
D6
RY2
RY3
CN2
BCN2
C14
0.01µ
25V
3
2
1
Q3
Q1
Q2
2
3
1
2
3
1
5V
R7
10K
NC
NC
NC
NC
5V
100µ
10V
R10
R11
5V
RA2
10K
(F) x5
D8
C9
220µ
16V
R13
10K(F)
R14
820(F)
C.T.
5V
R15
2.7K(F)
R16
22.6K(F)
C10
10µF
16V
C11
10µF
16V
R17
15K(F)
R18
15K(F)
2
1
PIPE TEMP
TH2 15K(25˚C)
ROOM TEMP
TH1 15K(25˚C)
R19
10K
R20 10K
R21 10K
R22 10K
CA1
1000pF x 4
NC
NC
CST8.0MTW
R26
680
R24
4.7K
R23
33K
5V
D9
12V
C12
10µF
16V
FAN MOTOR
RPM SIGNAL
3
2
1
IC 1
IC 5
R25
1.2K
R27
4.7K
C17
0.1µF
50V
TEST
PST591D
CN5
CA2
1000pF x 4
R28
680
R29
330
R30
10K
1
2
3
4
5
1
2
3
4
5
LED 102 (YELLOW) TIMER LED
LED 101 (RED) OPERATION LED
C101
33µF
10v
BCN3
CN103
RECEIVER UNIT
JP12
NC
NC
NC
NC
NC
BCN2
BCN2
CN2
CN2
R6
560
1W
50Hz
220/240V
EVAPORATOR
EARTH LINE
NEUTRAL LINE
COMPRESSOR
VALVE COIL
OUT DOOR
FAN MOTOR
DTC143ZS
DTC143ZS
DTC143ZS
6
5
4
3
3
3
5V
5V
LM7812CT
LM7805CT
BLUE
BLACK
5V
C7
C8
R9
R12
2.4KF
33KF
1.8K
FAN H
FAN M
FAN L
MODEL A
MODEL B
D7
TERMINAL
BOARD 1
RED
G
V
A
1K
RY1
CNR3
F
G
I
O
RY4
CN4
0.1µ
50V
5V
1
3
2
L
10
AY-A184E
AY-A244E
AE-A184E
AE-A244E
AY-A244E
AE-A184E
AE-A244E
Figure L-4. Printed Wiring Board for AY-A244E
11
AY-A184E
AY-A244E
AE-A184E
AE-A244E
AY-A244E
AE-A184E
AE-A244E
MICROCOMPUTER CONTROL SYSTEM
1. Temperature control characteristic
1-1
COOL operation
In the “COOL” mode, the thermostat circuit is
controlled by four thermostat lines (C1 thru C4).
In the “COOL” mode, the thermostat circuit is
controlled by four thermostat lines (C1 thru C4).
1-3
HEAT operation
In the “HEAT” mode, the thermostat circuit
is controlled by six thermostat lines (H01 thru H4).
In the “HEAT” mode, the thermostat circuit
is controlled by six thermostat lines (H01 thru H4).
Figure Y-1
1-2
DRY operation
In the “DRY” mode, the thermostat circuit is
controlled by three thermostat lines (D1 thru D3).
In the “DRY” mode, the thermostat circuit is
controlled by three thermostat lines (D1 thru D3).
Figure Y-3
2. Operation modes
2-1
COOL operation
The compressor turns on or off, at the thermostat
lines C3 and C4. The outdoor fan motor is also
controlled with the compressor.
The compressor turns on or off, at the thermostat
lines C3 and C4. The outdoor fan motor is also
controlled with the compressor.
Figure Y-2
Figure Y-4
18
32
C1
C2
C3
C4
17.5
18.5
19.5
20.5
31.5
32.5
33.5
34.5
Preset temperature (˚C)
("THERMO" switch)
("THERMO" switch)
Room temperature (
˚C)
Room temperature(
˚C)
Preset temperature (˚C)
(THERMO" switch)
(THERMO" switch)
18
32
D1
D2
D3
17.5
18.5
19.5
31.5
32.5
33.5
Preset temperature (˚C)
("THERMO" switch)
("THERMO" switch)
H4
H3
H2
H1
H02
H01
17
19
21
22
24
26
31
33
35
36
38
40
18
32
Room temperature(
˚C)
Room temperature(
˚C)
Preset temperature (˚C)
Room temperature transition
C3
C4
States 1 & 3 : Compressor ON
State 2 : Compressor OFF
State 2 : Compressor OFF
1
2
3
12
AY-A184E
AY-A244E
AE-A184E
AE-A244E
AY-A244E
AE-A184E
AE-A244E
2-3
Heat operation
The compressor turns off, at State 2 , turns on
continuously at State 1 & 3 .
The compressor turns off, at State 2 , turns on
continuously at State 1 & 3 .
Figure Y-6
2-4
Fan only operation
The indoor fan motor always turns on.
The indoor fan motor always turns on.
3. Fan speed
Fan speeds are given by the indoor fan motor, “M”,
“L” and “UL”, which are available in the following
operation mode.
“L” and “UL”, which are available in the following
operation mode.
Table Y-2
FAN Switch
HEAT
COOL FAN ONLY
HIGH
M
M
M
LOW
L
L
L
SOFT
UL
UL
UL
Figure Y-5
Table Y-1
Compressor
Fan Speed
Cooling zone
ON
“UL”
Dehumidifying
ON
“D”
zone
Circulating
OFF
“D” or OFF
zone
2-2
DRY operation
On the switch on, the compressor always starts to
operate for 2 minutes with fan speed “D” (slower
than “UL”).
The microcomputer reads the room temperature 2
minutes after this first compressor operation.
This room temperature is set as the preset
temperature automatically.
The preset temperature ranges from 18˚C to 32˚C.
When the room temperature is below 18˚C, the
preset temperature is set to 18˚C, and when the
room temperature is over 32˚C, the preset
temperature is set to 32˚C.
Dry operation is divided into three zones (Cooling
zone, Dehumidifying zone and Circulating zone)
by thermostat lines (D1 to D3), and the compressor
and the fan motor are controlled in each zone as
shown in Table Y-1.
On the switch on, the compressor always starts to
operate for 2 minutes with fan speed “D” (slower
than “UL”).
The microcomputer reads the room temperature 2
minutes after this first compressor operation.
This room temperature is set as the preset
temperature automatically.
The preset temperature ranges from 18˚C to 32˚C.
When the room temperature is below 18˚C, the
preset temperature is set to 18˚C, and when the
room temperature is over 32˚C, the preset
temperature is set to 32˚C.
Dry operation is divided into three zones (Cooling
zone, Dehumidifying zone and Circulating zone)
by thermostat lines (D1 to D3), and the compressor
and the fan motor are controlled in each zone as
shown in Table Y-1.
Room temperature
Preset temperature
Room
temperature
transition
temperature
transition
D3
D2
D1
States 1 & 5 : Cooling zone
States 2 & 4 : Dehumidifying zone
States 3 : Circulating zone
States 2 & 4 : Dehumidifying zone
States 3 : Circulating zone
3
4
5
1
2
Room temperature
Preset temperature
Room temperature transition
H2
H1
States 1 & 3 : Compressor ON
State 2 : Compressor OFF
State 2 : Compressor OFF
3
1
2