DOWNLOAD Sharp AE-A184 Service Manual ↓ Size: 1.44 MB | Pages: 44 in PDF or view online for FREE

Model
AE-A184
Pages
44
Size
1.44 MB
Type
PDF
Document
Service Manual / Specification
Brand
Device
Air Conditioner
File
ae-a184.pdf
Date

Sharp AE-A184 Service Manual / Specification ▷ View online

25
AY-A184E
AY-A244E
AE-A184E
AE-A244E
Cycle temperature and service port pressure
ISO Cooling and heatpump condition
(at 220V refrigerant pipe length 7.5 m)
ISO
 Cooling and Heatpump condition
Dimension of Capillary tube
For AY-A184E
For AY-A244E
O.D.
I.D.
L
Capillary tube A
Capillary tube B
Capillary tube C
o 3.5
o 2.7
o 2.4
o 2.4
o 0.8
900
600
1000
o 3.5
O.D.
I.D.
L
Capillary tube 
o 3.2
o 1.9
600
AY-A184E
AY-A244E
Cooling
Cooling
Heating
Heating
Model
NO. Condition
1
2
3
4
Service port pressure
93˚C
84˚C
78˚C
88˚C
39˚C
45˚C
3˚C
1˚C
14˚C
16˚C
43˚C
42˚C
6˚C
8˚C
-3˚C
-2˚C
0.45MPa
0.47MPa
1.75MPa
1.90MPa
Indoor side
Outdoor side
Temperature (˚C)
Temperature (˚C)
Relative humididity (%)
Relative humididity (%)
27
48
35
40
20
37
 7
87
Cooling
Heating
26
AY-A184E
AY-A244E
AE-A184E
AE-A244E
PERFORMANCE CURVES
Figure P-1. At Cooling for AY-A184E
Figure P-2. At Heating for AY-A184E
13600
20400
Cooling capacity(BTU/h)
2500
4.0
4.5
5.0
5.5
6.0
(KW)
2000
1500
17
16
Input(W)
15
14
13
12
11
10
9
Outside air temp.(˚C)
Outlet air temp.(˚C)
3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7
3 8 3 9 4 0
Indoor air temp. : 20˚C
Indoor fan speed : Hi
15300
18700
20400
22100
Heating capacity(BTU/h)
5.0
5.5
6.5
7.0
(KW)
2000
2500
1500
50
Input(W)
Outside air temp.(˚C)
Outlet air temp.(˚C)
6.0
4.5
4.0
45
40
35
30
25
20
-10
-8
-6
-4
-2
0
2
4
6
8
10
1000
17000
23800
Indoor air temp. : 27˚C
Indoor humidity : 47RH%
Indoor fan speed : Hi
13600
18700
17000
15300
27
AY-A184E
AY-A244E
AE-A184E
AE-A244E
Figure P-3. At Cooling for AY-A244E
Figure P-4. At Heating for AY-A244E
18700
22100
23800
22500
Cooling capacity(BTU/h)
3000
5.5
6.0
6.5
7.0
7.5
(KW)
2500
2000
15
14
Input(W)
13
12
11
10
9
8
7
Outside air temp.(˚C)
Outlet air temp.(˚C)
3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7
3 8 3 9 4 0
Indoor air temp. : 20˚C
Indoor fan speed : Hi
25500
28900
Heating capacity(BTU/h)
6.0
7.0
7.5
8.5
9.0
(KW)
3000
2500
60
Input(W)
Outside air temp.(˚C)
Outlet air temp.(˚C)
8.0
6.5
55
50
45
40
35
30
-10
-8
-6
-4
-2
0
2
4
6
8
10
2000
27200
30600
Indoor air temp. : 27˚C
Indoor humidity : 48RH%
Indoor fan speed : Hi
23800
22100
20400
20400
3500
28
AY-A184E
AY-A244E
AE-A184E
AE-A244E
REFRIGERANT PIPE INSTALLATION WORKS
Refrigerant pipe length and level difference between the indoor and outdoor units.
The shorter refrigerant pipe, the highter the machine capabillity. Keep the pipeline as short as possible.
If actual pipe length exceeds 7.5m, and refrigerant (R-22) 15g per 1m.
MODEL 
AY-A184E
AY-A244E
PIPE SIZE
GAS
LIQUID
STANDARD PERMISSIBLE
LENGTH
STANDARD LEVEL
DIFERENCE
1/2"
5/8"
1/4"
1/4"
15m
10m
15m
10m
Page of 44
Display