4.3. Adjustment for CRT CUT OFF
Preparation:
 1. Connect the oscilloscope probe to (GREEN CATHODE) on L Board.
 2. Screen VR min.
 3. Set the data Sub Bright, Bright.
 4. In service Mode at “Bright” dac press [5] in factory mode to enter vertical line and adjust by volume down or up button.
 5. Adjust “Screen VR” to set voltage as in Table 1.
4.4. Adjustment Procedure
4.4.1. +B Voltage
Item / preparation
 1. Operate the TV set.
 2. Set control as follows :
Brightness ........... minimum
Contrast ............... minimum
Adjustment procedure
 1. Confirm the DC voltage at the indicated test points, as follows :
TPA 15 : 3.35 V ± 0.2
TPA 16 : 141 V ± 2
TPA 17 : 8.2 V ± 0.35
TPA 18 : 1.85 V ± 0.15
TPA19 : 5.30 V ± 0.2
TPA20 : 220 V ± 15
4.4.2. High Voltage
Item / preparation
 1. Receive the crosshatch pattern.
 2. Set to 0 Beam.
Screen VR .......... minimum
Contrast .............. minimum
Adjustment procedure
 1. Connect a DC voltage meter to TPA 16 and confirm that the +B voltage is 141.0 V ± 2.
 2. Connect a high frequency voltmeter to heater and confirm that voltage reads 6.3 V (RMS) ± 0.3.
 3. Normalize the brightness and contrast.
9
TX-29RX20T
4.5. Adjustment of Purity
 1. INSTRUMENTS
 a. Purity Jig
 b. Helmhortz device
 2. PREPARATION
 a. Set the Helmhortz device to local magnetic field.
Horizontal : 0 ± 0.03 × 10-4T
 b. Aging should be performed over 60 minutes.
 c. Receive the purity pattern (White pattern).
 d. Picture menu : CONTRAST ... Max. BRIGHT ... Max.
 e. Set V-CENTER to [4].
 f. 
Static convergence should have been roughly adjusted.
 g. Connect DC current meter through FBT (pin 3) and adjust to [1200 ± 10%] µA.
 3. ADJUSTMENT
 a. Set both purity magnets’ knobs to top.
 b. Adjust the purity so that the markers on monitor scope of purity jig become symmetrical in horizontal direction.
 c. Only for stripe CRT, correct vertical centre by purity magnet too.
 d. Set up deflection yoke so that the position of deflection yoke becomes [10 µm ± 5] forward on monitor scope at this time by
attention note to tile deflection yoke.
 e. Repeat procedures (a) ~ (d).
 f. 
Tighten deflection yoke band.
 g. Adjust beam landing by microscope. (Only for model change or check instruments)
10
TX-29RX20T
ADJUSTMENT OF CONVERGENCE
 1. INSTRUMENT
 a. Helmhortz device
 2. PREPARATION
 a. Set the Helmhortz device to local magnetic field.
Horizontal : 0 ± 0.03 × 10-4T
 b. Receive the crosshatch pattern.
 c. Picture menu : DYNAMIC Normal and adjust BRIGHT DAC until gray portion of crosshatch.
 d. Set DY to CRT not to tilt (up and down and left right).
 3. ADJUSTMENT
 a. Static Convergence Adjustment
 a. Make sure that the magnets are positioned as shown as in Fig. 1.
 b. Adjust the 4-pole magnets (Fig. 1) to align centre dots of R and B adjust 6-pole magnets to align centre dots to G.
 c. After adjustment, secure magnets with magnet lock of white lacquer.
 • Beams move with rotating when static magnet is turned. Rotational reduce of beams differs by angle of two
magnets. Therefore, repeat magnet adjustment several times so that all are aligned completely.
 b. YHC, YV, XV Adjustment (Fig. 2)
 a. Adjust that static and Dynamic convergence is best with YHC VR, YV VR and XV coil. In case static convergence is
tilted, repeat (1) Static Convergence Adjustment.
 c. Dynamic Convergence Adjustment
 a. When dynamic convergence is bad, fix permalloy between neck and DY so that dynamic convergence best.
Fig. 1
 4. CONFIRM THAT LEFT UPPER SIDE LINE IS STRAIGHT.
When left upper side line is not straight, put magnet on DY and adjust the left upper side line so it is straight.
Fig. 2
11
TX-29RX20T
FOCUS ADJUSTMENT
 1. PREPARATION
 a. Receive crosshatch pattern E-4.
 b. Picture menu : DYNAMIC NORMAL
For Philippines & Panamex model
 a. Receive the crosshatch pattern. ( US 6 )
 b. Picture menu : DYNAMIC NORMAL
 2. ADJUSTMENT
 a. Adjust focus VR for best position.
Adjust focus base on no.3 line
Fig 1. Crosshatch Pattern
12