Panasonic TC-15DT2 Service Manual ▷ View online
10.5. Video level adjustment
10.5.1. NTSC picture RF
Measuring instrument
Connection
PICTURE ADJUST
LCD AI
Remote control transmitter
RF signal
Oscilloscope
RF signal
Oscilloscope
TS7~TS10 (GND)
TS8~TS10 (GND)
TS9~TS10 (GND)
TS8~TS10 (GND)
TS9~TS10 (GND)
NORMAL
OFF
PIC MODE
DYNAMIC
•
•
•
• Receive 75% color bar signal
•
•
•
• Enter the adjustment mode and adjust the amplitude level of each signal in the following steps.
1. Y signal (TS7)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below YGAIN indication so that the
value below MAX indication becomes D4. When adjusted, measure the amplitude between pedestal and white peak.
value below MAX indication becomes D4. When adjusted, measure the amplitude between pedestal and white peak.
2. B-Y signal (TS8)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below B-Y indication so that the
amplitude (yellow-blue) at TS8becomes equal to the value measured in the YGAIN adjustment.
amplitude (yellow-blue) at TS8becomes equal to the value measured in the YGAIN adjustment.
3. R-Y signal (TS9)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below R-Y indication so that the
amplitude (cyan-red) at TS9 becomes equal to the value measured in the YGAIN adjustment.
amplitude (cyan-red) at TS9 becomes equal to the value measured in the YGAIN adjustment.
10.5.2. NTSC picture DVD
Measuring instrument
Connection
PICTURE ADJUST
LCD AI
Remote control transmitter
DVD signal
Oscilloscope
DVD signal
Oscilloscope
TS7~TS10 (GND)
TS8~TS10 (GND)
TS9~TS10 (GND)
TS8~TS10 (GND)
TS9~TS10 (GND)
NORMAL
OFF
PIC MODE
DYNAMIC
•
•
•
• Receive 100% color bar signal with built-in DVD.
•
•
•
• Enter the adjustment mode and adjust the amplitude level of each signal in the following steps.
1. Y signal (TS7)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below YGAIN indication so that the
value below MAX indication becomes D4. When adjusted, measure the amplitude between pedestal and white peak.
value below MAX indication becomes D4. When adjusted, measure the amplitude between pedestal and white peak.
2. B-Y signal (TS8)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below B-Y indication so that the
amplitude (yellow-blue) at TS8becomes equal to the value measured in the YGAIN adjustment.
amplitude (yellow-blue) at TS8becomes equal to the value measured in the YGAIN adjustment.
3. R-Y signal (TS9)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below R-Y indication so that the
amplitude (cyan-red) at TS9 becomes equal to the value measured in the YGAIN adjustment.
amplitude (cyan-red) at TS9 becomes equal to the value measured in the YGAIN adjustment.
10.5.3. NTSC picture video (VBS)
Measuring instrument
Connection
PICTURE ADJUST
LCD AI
Remote control transmitter
Video signal
Oscilloscope
Video signal
Oscilloscope
TS7~TS10 (GND)
TS8~TS10 (GND)
TS9~TS10 (GND)
TS8~TS10 (GND)
TS9~TS10 (GND)
NORMAL
OFF
PIC MODE
DYNAMIC
•
•
•
• Receive 100% color bar signal at video input 1.
•
•
•
• Enter the adjustment mode and adjust the amplitude level of each signal in the following steps.
1. Y signal (TS7)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below YGAIN indication so that the
value below MAX indication becomes D4. When adjusted, measure the amplitude between pedestal and white peak.
value below MAX indication becomes D4. When adjusted, measure the amplitude between pedestal and white peak.
2. B-Y signal (TS8)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below B-Y indication so that the
amplitude (yellow-blue) at TS8becomes equal to the value measured in the YGAIN adjustment.
amplitude (yellow-blue) at TS8becomes equal to the value measured in the YGAIN adjustment.
3. R-Y signal (TS9)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below R-Y indication so that the
amplitude (cyan-red) at TS9 becomes equal to the value measured in the YGAIN adjustment.
amplitude (cyan-red) at TS9 becomes equal to the value measured in the YGAIN adjustment.
33
TC-15DT2
10.5.4. NTSC picture video (S terminal)
Measuring instrument
Connection
PICTURE ADJUST
LCD AI
Remote control transmitter
Video signal
Oscilloscope
Video signal
Oscilloscope
TS7~TS10 (GND)
TS8~TS10 (GND)
TS9~TS10 (GND)
TS8~TS10 (GND)
TS9~TS10 (GND)
NORMAL
OFF
PIC MODE
DYNAMIC
•
•
•
• Receive 100% color bar signal at video input 1 (S terminal).
•
•
•
• Enter the adjustment mode and adjust the amplitude level of each signal in the following steps.
1. Y signal (TS7)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below YGAIN indication so that the
value below MAX indication becomes D4. When adjusted, measure the amplitude between pedestal and white peak.
value below MAX indication becomes D4. When adjusted, measure the amplitude between pedestal and white peak.
2. B-Y signal (TS8)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below B-Y indication so that the
amplitude (yellow-blue) at TS8becomes equal to the value measured in the YGAIN adjustment.
amplitude (yellow-blue) at TS8becomes equal to the value measured in the YGAIN adjustment.
3. R-Y signal (TS9)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below R-Y indication so that the
amplitude (cyan-red) at TS9 becomes equal to the value measured in the YGAIN adjustment.
amplitude (cyan-red) at TS9 becomes equal to the value measured in the YGAIN adjustment.
34
TC-15DT2
11 Conductor Views
11.1. P-Board
PARTS LOCATION
IC
TRANSISTOR
P-BOARD (FOIL SIDE)
TP
ADDRESS INFORMATION
IC810
C-1
IC2300
E-3
IC2301
C-1
IC2302
D-2
Q800
B-3
Q801
B-1
Q805
C-3
Q806
B-4
Q807
C-1
Q808
B-4
Q813
B-1
Q814
B-3
Q815
C-4
Q2300
B-3
Q2301
E-2
Q2302
E-2
Q2303
E-1
Q2306
D-2
Q2307
C-2
Q2308
D-1
Q2309
C-2
Q2310
D-2
TP800
B-3
TP801
B-3
TP802
B-2
TP803
B-2
TP804
B-3
TP805
D-3
TP806
C-1
TP807
E-3
TP808
C-2
TP809
A-1
TP811
A-1
TP813
E-3
TP814
C-4
TP815
E-4
TP817
B-3
TP818
C-1
TP819
B-4
TP820
C-3
TP821
B-4
TP822
D-3
TP823
E-4
TP824
C-4
TP825
E-4
TP2300
E-3
TP2307
E-2
TP2311
E-2
TP2314
E-1
TP2328
D-2
TP2329
E-2
TP2330
E-3
TP2331
C-1
TP2332
E-1
A
B
C
D
E
1
2
3
4
P-BOAD (FOIL SIDE)
TXN/P1FHR
TXN/P1FHR
TC-15DT2
35
A
B
C
D
E
1
2
3
4
P-BOAD (COMPONENT SIDE)
TXN/P1FHR
TXN/P1FHR
PARTS LOCATION
IC800
D-1
IC801
B-3
IC802
C-1
IC803
E-1
IC804
C-3
IC805
A-3
IC806
C-3
IC807
A-4
IC808
D-4
IC810
C-1
IC2301
B-1
IC2302
B-2
Q2302
A-2
Q2304
A-3
Q2305
A-2
Q2309
C-2
IC
TRANSISTOR
P-BOARD (COMPONENT SIDE)
ADDRESS INFORMATION
TC-15DT2
36