DOWNLOAD Panasonic LCD-201411 / AVC-201411 / AX900 Service Manual ↓ Size: 1.26 MB | Pages: 56 in PDF or view online for FREE

Model
LCD-201411 AVC-201411 AX900
Pages
56
Size
1.26 MB
Type
PDF
Document
Service Manual / Other
Brand
Device
TV / LCD TV
File
lcd-201411-avc-201411-ax900.pdf
Date

Panasonic LCD-201411 / AVC-201411 / AX900 Service Manual / Other ▷ View online

FR
LD
AP
P
A
P2
A02
Q7403/05
9
17
5V
IC5420
IC8101/03
3.3V
IC8950
3.3V
IC5400
1.8V
IC5703
1.8V
0.9V
P
16
V
Q7402
IC8104
HDMI3.3V
SUB1.8V
SUB_M_0.9V/SIB_I_0.9V
SUB3.3V
REG_1.8V
48/40V
LCD_TV_SUB_ON
48V
Output
16V
Output
P
A
2
0
0
0
1.1V
IC5705
DMD 1.1V
D
C
D
C
E
N
12V
Panel_VCC_ON
FR1
3-5
LCD Module
PNL12V
SUB5V
T-CON
PFC
T7201
IC7201
DC/DC
IC7301
P16V
IC5000
ANALOG 
ASIC
IC8000
Peaks
Pro5
<           and            : A board (PNL voltage) >
4
5
16V
DC/DC
IC7405
STB5V
IC1800
STB3.3V
VLED(*)
56/68V
33
(*)The DC level is different by the LCD panel.
Start up Operation (AX900) -10
IC1100
Stand-by/
Control
CPU
LED Drive
IC7700-07
DC/DC
IC7550
/52/54/56
2
FR16
15
7
BL_ON
BL_ON
3.3V
1.5V
1.2V
1.8V
0.9V
STB_I_1.2V
STB_I_1.5V
STB_I_1.8V
STB_I_0.9V
F16V
LD4
FR30/31
2
12
1-4
9-12
1-4
1-4
FR20
A15
BL_SOS
40
4
7
45
48
FR15
A16
12
2
Tr
AX900
IC9500
FRC(GCX)
Back Light
(TNPA5936**)
Transformer
T7301
T7302
The P16V is also used to generate the PNL-Voltage on FR board. IC1100 outputs the 
Panel VCC ON signal. IC1800 starts generating the PNL12V by this signal. The PNL12V 
is provided to T-con circuit of the LCD Module. 
After that, IC1100 outputs the BL_ON command to the IC9500 on the FR board. The 
IC9500 output the BL_ON command to AP board and LD board. 
It turns on the IC7550-7556 for DCDC in AP board and IC7700-7707 for LED backlight 
drive in LD board. Then the backlight starts lighting, and LCD panel displays the pictures. 
If the backlight drive circuit does not work normally, the BL_SOS signal is informed to 
the IC1100. At that time, IC1100 stops outputting the TV_SUB_ON signal and blinks the 
red LED 1 times.
<           and            : A board (PNL voltage) >
4
5
34
Start up Operation (AX900) -11
AX900
P
P
P
Power-SW/
Remote
Simple Power On Sequence
TV_SUB_ON signal
Power on
PANEL_VCC_ON signal
BL_ON_ON signal
< Display start >
PFC circuit (IC7201/T7201/7202 ) start working
16V/48(40)V output
PNL12V output
STB5V output
( Plug in )
A
A
A
A
35
36
5. SOS Protection Circuit and Troubleshooting
The troubleshooting of AX670/AX630 model is basically same as 
Full HD(LD6) model. Refer to the Technical Guide “ITD1404901GE” .