DOWNLOAD Panasonic KX-TGH210UAB / KX-TGH212UAB / KX-TGH220UAB / KX-TGHA20RUB Service Manual ↓ Size: 7.14 MB | Pages: 90 in PDF or view online for FREE

Model
KX-TGH210UAB KX-TGH212UAB KX-TGH220UAB KX-TGHA20RUB
Pages
90
Size
7.14 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / DIGITAL CORDLESS PHONE
File
kx-tgh210uab-kx-tgh212uab-kx-tgh220uab-kx-tgha20ru.pdf
Date

Panasonic KX-TGH210UAB / KX-TGH212UAB / KX-TGH220UAB / KX-TGHA20RUB Service Manual ▷ View online

41
KX-TGH210UAB/KX-TGH212UAB/KX-TGH220UAB/KX-TGHA20RUB
(F)* Battery Monitor Check
-
1. Apply 2.25 V between BATT+ and BATT-.
2. Execute the command 
sendchar PAD
sendchar LED 0
sendchar CRX 0 1
sendchar AD1
It assumes that the return value is XX.
a) XX: 70: No need to adjust
b) XX: 66 ~ 6F: Need to adjust
XX: 71 ~ 7A: Need to adjust
Write AD value of 2.25 V to EEPROM.
ex) read data: XX = 6A, write data: YY = 6A
read data: XX = 73, write data: YY = 73
EEPROM = 0009(Low Voltage) write “YY”
Execute the command “wreeprom 00 09 01 YY”.
EEPROM = 000A(No Voltage) write “YY -C"
Execute the command “wreeprom 00 0A 01 ZZ”.
Note:
ZZ = YY - C
c) XX: 00 ~ 65: Reject
XX: 7B ~ FF: Reject
IC1, R45
(G)
Battery Low 
Confirmation
-
1. Apply 2.40 V between BATT+ and BATT-.
2. Confirm that there is no flashing of Battery Icon.
3. Apply 2.25 V ± 0.08 V between BATT+ and BATT-.
4. Confirm that there is flashing of Battery Icon.
IC1, R45
(H)* BBIC Clock Adjustment
CKM
1. Apply 2.6 V between BATT+ and BATT- with DC power.
2. Input Command “sendchar sfr”, then you can confirm the current value.
3. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
4. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CKM
executing the command “sendchar sfr xx xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
Note:
Clear the registered information for Base Unit before measurement, because the
Frequency will not possibly get stable due to the registered information.
Pressing the button of "3" "5" "7" "#"clears the registration.
Register to it on Base Unit after measurement. 
IC1, X1, C47
 
(I)*
Transmitted Power 
Confirmation
-
Short Antenna pattern to GND.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030405
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL = -70 dBm
• PACKET: PP32Z
2. Execute the command “sendchar TST 01 02 03 04 05".
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is 19 dBm ~ 25 dBm.
IC1, C801, 
C859, C860, 
C861, C862
(J)* Modulation Check and 
Adjustment
-
Follow steps 1 to 3 of (I).
4.Confirm that the B-Field Modulation is -350 ± 50/+350 ± 50 kHz/div using data
type Fig 31.
Refer to (I)
(K)*
Frequency Offset 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Offset is < ± 20 kHz.
Refer to (I)
(L)*
Sensitivity Receiver 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Set DECT tester power to -88 dBm.
5.Confirm that the BER is < 1000 ppm.
Refer to (I)
(M)*
Power RAMP 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Confirm that Power RAMP is matching.
Refer to (I)
(N)
Audio Check and 
Confirmation
-
1. Link to BASE which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 50 mA.
3. Input -45 dBm (600 
)/1 kHz to MIC of Handset. Measure the Level at Line I/F
and distortion level.
4. Confirm that the level is -3.0 dBm ± 5 dB and that the distortion level is < 5 %
at TEL Line (600 
 Load).
5. Input -20 dBm (600 
)/1 kHz to Line I/F. Measure the Level at Receiver of
Handset and distortion level (Receive volume set to second position from
minimum).
6. Confirm that the level is -27.0 dBm ± 4 dB and that the distortion level is < 5 %
at Receiver (34 
 Load).
IC1, C12, C11, 
C13, MIC, 
R23, R24, 
R25, RA4, 
C70, C71
Items
Check 
Point
Procedure
Check or 
Replace Parts
42
KX-TGH210UAB/KX-TGH212UAB/KX-TGH220UAB/KX-TGHA20RUB
(O) SP phone Audio Check 
and Confirmation
-
1. Link to Base which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 50 mA.
3. Set the handset off-hook using SP-Phone key.
4. Input -30 dBm (600 
)/1 KHz to Line I/F and measure Receiving level at SP+
and SP-.
5. Confirm that the level is -7 dBm ± 3 dB and that the distortion level is < 5 %. 
(vol = Max at SP (8 
 Load))
IC1, C78, C79, 
R76, R77
(P)
Charge Pump 3.0 V 
Supply Confirmation
CP3V
1. Confirm that the voltage between testpoint CP3.0V and GND is 3.0 V ± 0.3 V. C30, C53, C29
(Q)
Charge Pump CP4V 
Supply Confirmation
CP4V
1. Confirm that the voltage between testpoint CP4V and GND is 4.0 V ± 0.3 V.
(Power is supplied when LED in on)
C52, C55, 
C30, C29
Items
Check 
Point
Procedure
Check or 
Replace Parts
43
KX-TGH210UAB/KX-TGH212UAB/KX-TGH220UAB/KX-TGHA20RUB
10 Disassembly and Assembly Instructions
10.1. Disassembly Instructions
10.1.1. Base Unit
10.1.1.1. KX-TGH210
ձ
Remove the 2 screws to remove
the cabinet cover.
Main P.C.Board
ղ
Remove the solders.
ճ
2 Screws
ձ
Cabinet cover
Solders
ղ
Main P.C.Board
Remove the screw to remove the
Jack Holder and Main P.C.Board.
 screws
Jack holder
44
KX-TGH210UAB/KX-TGH212UAB/KX-TGH220UAB/KX-TGHA20RUB
10.1.1.2. KX-TGH220
ձ
Remove the 2 screws to remove
the cabinet cover.
ղ
Remove the solders.
ճ
Remove the screw to remove the
Jack Holder.
Main P.C.Board
2 Screws
ձ
Cabinet cover
Solders
ղ
 screws
Jack holder
Main P.C.Board
Page of 90
Display