9.1.10. Power failure mode
9.1.10.1. Operation with supply from handset under electric power failure
Pull out AC plug of base from the socket once base and handset make link.
Pull handset on base under electric power failure.
Pull handset on base under electric power failure.
Cross Reference:
Behavior of Electric Power Failure (P.16)
Does set make link in 90 seconds?
Yes
OK
No
What is indicated
on LCD of
handset?
None
Check user setting about power failure.
Is pulse voltage of
handset CHG+
settled from 0.2V to
2.0V in the state of
connecting base and
handset?
Check charge terminal's impurities.
Press OFF and check again.
Press OFF and check again.
"Base no power ..."
"Place on
base ..."
base ..."
Check R18 or R19 or BBIC of handset
Yes
No
Check supply circuit of base.
"Supplying ..."
What volt is handset
CHG+ in the state
of connecting base
and handset?
Over 2.0V
Under 2.0V
Check supply circuit of handset.
Check supply circuit of base and
charge terminal's impurities.
charge terminal's impurities.
Battery Low state
Use the battery charged enough
and check again.
and check again.
38
KX-TGH210UAB/KX-TGH212UAB/KX-TGH220UAB/KX-TGHA20RUB
9.2.
Troubleshooting by Symptom (Base Unit and Charger Unit)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not.
(*1) or not.
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to Check Point (Base Unit) (P.38)
level in detail.
(*2) Refer to Check Point (Base Unit) (P.38)
9.2.1.
Check Point (Base Unit)
Please follow the items below when BBIC or EEPROM or FLASH is replaced.
Note:
After the measuring, suck up the solder of TP.
*: The Setting Method of JIG (Base Unit) (P.49) is required beforehand.
The connections of simulator equipment are as shown in Adjustment Standard (Base Unit) (P.51).
*: The Setting Method of JIG (Base Unit) (P.49) is required beforehand.
The connections of simulator equipment are as shown in Adjustment Standard (Base Unit) (P.51).
Symptom
Remedy (*2)
You don’t have DECT Tester.
You have DECT Tester.
(Model Number: CMD60)
You cannot dial.
Check item (A) - (I).
Check item (A) - (I), (J) - (N).
You cannot hear the caller’s voice.
Check item (A) - (G), (O).
Check item (A) - (G), (J) - (N), (O).
You cannot use the handset a little away from base unit even if the
handset is within range of the base unit.
handset is within range of the base unit.
-
Check item (J) - (N).
The acoustic transmit level is high or low.
Check item (O).
Check item (O).
The acoustic reception level is high or low.
Check item (O).
Check item (O).
Base unit and handset do not link to each other.
Check item (A) - (I).
Check item (A) - (N).
The unit cannot charge.
Check item (P).
Check item (P).
TAM does not work. (for KX-TGH220 only)
Check item (Q).
Check item (Q).
Items
Check
Point
Procedure
Check or
Replace Parts
(A)
3.0 V Supply
Confirmation
Confirmation
VDD3
1. Confirm that the voltage between test point VDD3 and GND is 3.0 V ± 0.2 V.
IC302, R321,
R322, C341,
C342 , R905,
D905
(B)
1.8 V Supply
Confirmation
Confirmation
VDD1
1. Confirm that the voltage between test point VDD1 and GND is 1.8 V ± 0.02 V.
2. Execute the command “VDD”, then check the current value.
3. Adjust the 1.8V voltage of VDD1 executing command “VDD XX“(XX is the
2. Execute the command “VDD”, then check the current value.
3. Adjust the 1.8V voltage of VDD1 executing command “VDD XX“(XX is the
value).
Q301, IC501,
R311, C311,
C516, C517
(C) Charge Pump 3.0V
Supply Confirmation
VDD5
1. Confirm that the voltage between test point VDD5 and GND is 3.0 V -0.1/+0.3
V.
IC501, C512
(D) Charge Pump 3.0V
Supply Confirmation
VDD4
1. Confirm that the voltage between test point VDD4 and GND is 3.0 V ± 0.2 V.
IC501, C509
(E)*
BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC501, X501
(F)* EEPROM Confirmation
-
1. EEP-ROM Confirmation (Execute the command "sendchar EPV").
2. Confirm the returned Value. (Value for reference is written at "EEPROM C/
2. Confirm the returned Value. (Value for reference is written at "EEPROM C/
SUM” in Software_Version_Table.xls).
IC501, RA611,
IC611, C611
(G)* BBIC Clock Adjustment
CKM
1. Confirm that the voltage between testpoint VDD4 and GND is less than 1.0 V.
2. Input Command “ sendchar sfr”, then you can confirm the current value.
3. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
4. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CKM
2. Input Command “ sendchar sfr”, then you can confirm the current value.
3. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
4. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CKM
executing the command “sendchar sfr xx xx (where xx is the value)” so that
the reading of the frequency counter is 10.368000 MHz ± 5 Hz.
the reading of the frequency counter is 10.368000 MHz ± 5 Hz.
IC501, X501,
C502
(H)* Hookswitch Check with
DC Characteristics
-
1. Connect Telephone Socket to Tel-simulator which is connected with 600
.
2. Set line voltage to 48 V and line current to 40mA at off-hook condition of
normal telephone.
3. Execute the command “hookoff”
4. Confirm that the line current is 40 mA ± 5 mA.
5. Execute the command “hookon”.
6. Confirm that the line current is less than + 0.8 mA.
4. Confirm that the line current is 40 mA ± 5 mA.
5. Execute the command “hookon”.
6. Confirm that the line current is less than + 0.8 mA.
P101, Q141,
R141, R142,
Q142, R144,
R145, D101,
R160, R162,
R169, R170,
D141, Q161,
R151, IC501
R141, R142,
Q142, R144,
R145, D101,
R160, R162,
R169, R170,
D141, Q161,
R151, IC501
checksum value
020A
program number
DE41EN
ex.)
39
KX-TGH210UAB/KX-TGH212UAB/KX-TGH220UAB/KX-TGHA20RUB
(I) DTMF Generator Check
-
1. Connect Telephone Socket to DTMF tester. (Load=600
)
2. Link Handset and push dial key.
3. Confirm DTMF character.
4. Confirm that the high Group is -7.0 ± 2 dBm.
5. Confirm that the low Group is -9.0 ± 2 dBm
3. Confirm DTMF character.
4. Confirm that the high Group is -7.0 ± 2 dBm.
5. Confirm that the low Group is -9.0 ± 2 dBm
IC501, C184,
Q161, D141
(J)*
Transmitted Power
Confirmation
-
ANTI_TP
Remove the Antenna before starting step from 1 to 7.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: FP
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• PMID: 00000
• RF LEVEL = -70 dBm.
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• PMID: 00000
• RF LEVEL = -70 dBm.
2. Execute the command ”sendchar TST”.
3. Execute the command “sendchar dmv 2 2”.
4. Check that “Signalling Status” has been set to “Locked”, then press “ACCEPT
3. Execute the command “sendchar dmv 2 2”.
4. Check that “Signalling Status” has been set to “Locked”, then press “ACCEPT
RFPI”.
5. Initiate connection from Dect tester (“set up connect”)
6. Execute the command “ANT1”.
7. Confirm that the NTP value at ANT is 18.5 dBm ~ 25.0 dBm.
6. Execute the command “ANT1”.
7. Confirm that the NTP value at ANT is 18.5 dBm ~ 25.0 dBm.
IC501, C851,
C860, C862,
C863, C859
(K)* Modulation Check and
Adjustment
-
ANTI_TP
Follow steps 1 to 6 of (J).
7.Confirm that the B-Field Modulation is -350 ± 50/+350 ± 50 kHz/div using data
type Fig31.
type Fig31.
Refer to (J)
(L)* Frequency Offset Check
-
ANTI_TP
Follow steps 1 to 6 of (J).
7.Confirm that the frequency offset is < ± 20 kHz.
Refer to (J)
(M)*
Sensitivity Receiver
Confirmation
-
ANTI_TP
Follow steps 1 to 6 of (J).
7.Set DECT tester power to -88 dBm.
8.Confirm that the BER is < 1000 ppm.
8.Confirm that the BER is < 1000 ppm.
Refer to (J)
(N)*
Power RAMP
Confirmation
-
Follow steps 1 to 6 of (J).
7.Confirm that Power RAMP is matching.
Refer to (J)
(O)
Audio Check
-
1. Link with Handset which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 50 mA.
3. Input -45 dBm (600
2. Set line voltage to 48 V and line current to 50 mA.
3. Input -45 dBm (600
)/1 kHz to MIC of Handset. Measure the Level at Line I/F
and distortion level.
4. Confirm that the level is -2.5 ± 5 dBm and that the distortion level is <5% at
TEL Line (600
Load).
5. Input -20 dBm (600
)/1kHz to Line I/F. Measure the Level at Receiver of
Handset and distortion level (Receive volume set to second position from
minimum).
minimum).
6. Confirm that the level is -27.0 ± 4 dBm and that the distortion level is <5 % at
Receiver (34
Load).
IC501, SA101,
P101, D101,
Q141, Q142,
R141, R142,
R144, R145,
D141, Q161,
R163, R164,
C171, C173,
R144, R145,
D141, Q161,
R163, R164,
C171, C173,
R178, C184
(P)
Charging Check
-
1. Connect Charge Contact 12
/2 W resistor between charge+ and charge-.
2. Measure and confirm voltage across the resistor is 3.9 V ± 0.4 V.
R371, R372,
D362, C351
(Q)
TAM Operation
Confirmation
(for KX-TGH220 only)
-
1. TAM Confirmation (Execute the command "sendchar VPI").
2. Confirm the returned Value (Value is "DD37RN 01").
2. Confirm the returned Value (Value is "DD37RN 01").
IC501, IC601,
R601, RA601,
C601
Items
Check
Point
Procedure
Check or
Replace Parts
40
KX-TGH210UAB/KX-TGH212UAB/KX-TGH220UAB/KX-TGHA20RUB
9.3.
Troubleshooting by Symptom (Handset)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not.
(*1) or not.
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to Check Point (Handset) (P.40)
level in detail.
(*2) Refer to Check Point (Handset) (P.40)
9.3.1.
Check Point (Handset)
Please follow the items below when BBIC or EEPROM is replaced.
Note:
After the measuring, suck up the solder of TP.
*: The Setting Method of JIG (Handset) (P.52) is required beforehand.
The connections of adjustment equipment are as shown in Adjustment Standard (Handset) (P.54).
*: The Setting Method of JIG (Handset) (P.52) is required beforehand.
The connections of adjustment equipment are as shown in Adjustment Standard (Handset) (P.54).
Symptom
Remedy (*2)
You don’t have DECT Tester.
You have DECT Tester.
(Model Number: CMD60)
Battery strength is not indicated correctly by Battery icon.
Check item (A) - (D), (E) - (G).
Check item (A) - (D), (E) - (G).
You cannot hear the caller’s voice.
Check item (A) - (C), (H), (N).
Check item (A) - (C), (H - (L)) - (N).
You cannot use handset little away from base unit even if the
handset is within range of the base unit.
handset is within range of the base unit.
-
Check item (I) - (M).
the Audio level is high or low.
Check item (N).
Check item (N).
The SP-Phone level is high or low.
Check item (O).
Check item (O).
Items
Check
Point
Procedure
Check or
Replace Parts
(A)* 1.8 V Supply Adjustment
1.8V
1. Confirm that the voltage between test point 1.8V and GND is 1.8 V ± 0.02 V.
2. Execute the command “VDD”, then check the current value.
3. Adjust the 1.8V voltage of 1.8V executing command “VDD XX“(XX is the
2. Execute the command “VDD”, then check the current value.
3. Adjust the 1.8V voltage of 1.8V executing command “VDD XX“(XX is the
value).
IC1, Q1, C44,
R45, C40, C45
(B)*
BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC1, X1, R61
(C)* EEP-ROM Confirmation
-
1. EEP-ROM Confirmation (Execute the command "sendchar EPV").
2. Confirm the returned Value. (Value for reference is written at "EEPROM C/
2. Confirm the returned Value. (Value for reference is written at "EEPROM C/
SUM” in Software_Version_Table.xls).
IC1, IC3, RA5,
C69
(D) Charge Control Check &
Charge Current Monitor
Check
-
1. Apply 5.0 V between CHG(+) and CHG(-) with DC power supply and set
current limit to 150 mA.
Confirm the indication of “charging” on LCD.
Confirm the indication of “charging” on LCD.
2. Confirm that the current limit LED of DC power supply is ON/OFF.
Confirm it after waiting over 1 minute at least.
(If charge control cannot be confirmed by this procedure, please use battery to
handset power supply and try again.)
handset power supply and try again.)
IC1, Q4 Q9,
Q2, Q3, R2,
Q2, Q3, R2,
R7, R8, R6,
R9, C19, R45
(E)* Charge Detection (OFF)
Check
-
1. Stop supplying 5.0 V to CHG (+) and CHG (-).
2. Confirm the indication of “charging” has been cleared.
2. Confirm the indication of “charging” has been cleared.
IC1, Q4 Q9,
Q2, Q3, R2,
Q2, Q3, R2,
R7, R8, R6,
R9, C19, R45
checksum value
program number
ex.)
B82C
DE42RN