69
KX-TG9127UAS/KX-TG9127UAT/KX-TGA910UAS/KX-TGA910UAT
11.4. The Setting Method of JIG (Handset)
11.4.1. Preparation
11.4.1.1. Equipment Required
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
• Frequency counter: it must be precise enough to measure intervals of 1Hz (precision; ±4ppm).
Hewlett Packard, 53131A is recommended.
• DC power: it must be able to output at least 1A current under 2.4V for Handset.
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope
11.4.1.2. JIG and PC
• Serial  JIG
JIG Cable: PQZZ1CD300E*
• PC which runs in DOS mode.
• Batch file CD-ROM for setting: PQZZTG9127UA
Note:
*: If you have the JIG Cable for TCD500 series 
(PQZZ1CD505E), change the following values of resis-
tance. Then you can use it as a JIG Cable for both TCD300 
and TCD500 series. (It is an upper compatible JIG Cable.)
11.4.2. PC Setting
11.4.2.1. Connections
Connect the DC Power or Battery to BAT+ and BAT- (Handset).
Connect the JIG Cable GND (black).
Connect the JIG Cable UTX (yellow) and URX (red).
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω) New value (kΩ)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
70
KX-TG9127UAS/KX-TG9127UAT/KX-TGA910UAS/KX-TGA910UAT
11.4.2.2. Batch file Settings
Note:
• “****” varies depending on the country.
11.4.2.3. Commands
See the table below for frequently used commands.
Command name
Function
Example
rdeeprom
Read the data of FLASH
Type “rdeeprom 00 00 FF”, and the data from address
“00 00” to “FF” is read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E
98” is written.
setfreq
Adjust Frequency of RFIC
Type “setfreq nn”.
getchk
Read checksum
Type “getchk”.
wreeprom
Write the data of FLASH
Type “wreeprom 01 23 45”. “01 23” is address and “45”
is data to be written.
71
KX-TG9127UAS/KX-TG9127UAT/KX-TGA910UAS/KX-TGA910UAT
11.5. Adjustment Standard (Handset)
When connecting the simulator equipment for checking, please refer to below.
11.5.1. Component View
Note:
(A) - (U) is referred to Check Point (Handset) (P.52).
L5
L4
F1
Q1
L1
D1
C1
C79
C78
C77
C132
C61
C25
C3
C60
D41
D51
ANT
ANT1
CHARGE-
CHARGE+
TP21
TP20
TP19
TP18
JTAG
SCLK
C75
C76
R78
R122
R121
R57
C18
C15
R62
C47
C43
TP11
TP10
TP12
R50
R54
R46
C12
C10
C36
BAT
BAT
GND
C14
C13
Q8
Q7
R51
R17
R16
R5 C130
D10
R72
R6
Q10
D6
C128
C127
C8
C68
L6
C64
D11
D2
C24
C69
R70
Q4
R14
R74
R73
R80
C46
R21
C93
R71
C70
C65
C66
C9
R27
R139
R138
R137
C42
C34
C48
R52
R61
Q15
R60
Q5
R125
R45 R64
R42
R63
C63
C33
C20
C2
C4 C35
C5
R13
IC7
IC2
IC3
IC6
D8
C131
C27
C62
C74
FLASH
SRAM
CN4
C57
C26
C28
C29
C30
C118
CLK
C115
C114
C120
C119
C44
C126
C73
R123
R66
C122
1
1
25
34
10
11
16
17
32
27
26
R128
R127
R44
C80
C32
C31
R47
R22
R26
R67
R49
R12
R33
R32
R35
R31
R36
Q9
Q11
C133
R15
C11
L7
C7
R135
R7
C16
C94
C45
Q3
Q12
Q13
Q14
R20
R82
R81
C6
13
8
102
103
128
65
39
64
R43
R25
R24
C23
C19
R40
R39
R41
R38
R37
R30
R23
R4
R3
R53
R34
R19
R129
R126
R130
R124
REV
SP
SP
REV
C72
C71
POWER
C129
URX
UTX
IC1
KX-TG9120/TGA910
X1
IC20
PQUP11445Z
A
BAT
(A
) (
D
) (
E
) (
F
) (
I)
(J
) (
K
) (
L
) (
R
)
(G
) (
H
) (
I) (
J
)
(A
) (
B
) (
C
)
(T
) (
U
)
OSC
AF VOLT
METER
LOOP
Simulator
Frequency
Counter
Dummy Base
Unit
GND
GND
GND
(K
)
CLK
TP12
TP11
1.8V
3V
4V
TP10
UTX
URX
150
SP-
REV+
REV-
SP+
8
6.3V
47uF
AF
GENERATOR
TP20
TP19
TP18
DC POWER
2.00-2.25V
(When at BATT LOW)
Oscilloscope
AF VOLT
METER
A
B
1
POWER KEY
DC POWER
2.30-2.60V
2.7V
Zener
PC
Digital
Volt Meter
AF
OSC
DC
6.5V
Current
Probe
Oscilloscope
TP21
(T
)
MIC-
MIC+
600
100
22pF
ANT1
GND
BAT
GND
DECT Tester
CMD60
(L
) (
M
) (
N
) (
O
)
(P
) (
Q
) (
R
) (
S
)
(T
) (
U
)
72
KX-TG9127UAS/KX-TG9127UAT/KX-TGA910UAS/KX-TGA910UAT
11.6. Things to Do after Replacing IC
Cautions:
Some of the content on this page may not apply to models from some countries. The contents below are the minimum adjust-
ments required for operation.
11.6.1. Base Unit
Before making the following adjustment, ensure you have carried out PC Setting (P.65) in The Setting Method of JIG (Base
Unit)
.
Note:
(*1) XX: country code, YY: revision number, ZZ: voice prompt
“XX”, “YY”, and “ZZ” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in JIG and
PC
 (P.65).
(*2) Refer to Check Point (Base Unit) (P.48)
11.6.2. Handset
Before making the following adjustment, ensure you have carried out PC Setting (P.69) in The Setting Method of JIG (Hand-
set)
.
Note:
(*3) Refer to Check Point (Handset) (P.52)
IC
Necessary Adjustment
BBIC
(IC7)
Programs for Voice processing, 
interface for RF and EEPROM
1. Make sure to connect the JIG cable, then detach the DC Power.
2. Execute the command “flw43x ************.hex”.
3. Connect the DC Power.
4. Press the PC Enter key once.
5. After a few minutes, “Successful upgrade” is displayed on the PC indicating down-
loading has finished.
6. Detach the JIG cable, then disconnect the DC Power.
7. Connect the DC Power.
8. Connect the JIG cable again, and execute the command “getchk”, then confirm the 
checksum value is correct.
• If the downloading fails, start again from step 1.
9. Default batch file: Execute the command “default.bat”.
10. Country version batch file: Execute the command “TG9120XXrevYY”. (*1)
11. Clock adjustment: Refer to Check Point (F). (*2)
EEPROM
(IC5)
Adjustment parameter data
(country version batch file, default 
batch file, etc.)
1. Change the address “0000” of EEPROM to “55”.
2. Default batch file: Execute the command “default.bat”.
3. Country version batch file: Execute the command “TG9120XXrevYY”. (*1)
4. Clock adjustment: Refer to Check Point (F). (*2)
FLASH
(IC9)
Voice prompt data
(vary depending on country ver-
sion)
1. Wait more than 15 seconds after connecting the JIG Cables.
2. Execute the command “VPDL06 -16M ZZ.bin”. (*1)
(writing time: approx. 2.5min.)
3. Confirm voice prompt version: Refer to Check Point (S). (*2)
IC
Necessary Adjustment
BBIC
(IC1)
Programs for Voice processing, 
interface for RF, Flash Rom and 
SRAM
1. Clock adjustment: Refer to Check Point (K). (*3)
2. 1.8 V setting and battery low detection: Refer to Check Point (A), (I) and (J). (*3)
Page of 105
Display

Click on the first or last page to see other KX-TG9127UAS / KX-TG9127UAT / KX-TGA910UAS / KX-TGA910UAT service manuals if exist.