KX-TG8551CAB/KXTG8561CAB/KX-TGA855RUB
9.1.1.
Check Power
9.1.1.1.
Base Unit
Is the AC Adaptor inserted into AC outlet? (*1)
Cross Reference:
Power Supply Circuit (P.16)
Note:
(*1) Refer to Specifications (P.7) for part number and supply voltage of AC Adaptor.
Is input of IC302 about 5.5 V?
Check C322, C342 are not shorted.
Check AC Adaptor.
Check Power Supply Circuit.
Is the output voltage of IC302 about 2.85V?
Does BBIC (IC501: XTAL1) oscillate at 10.368 MHz?
Check X501.
Check BBIC (IC501).
Is the Collector of Q301 about 1.8 V?
Is BBIC (IC501: RSTn) High?
Check BBIC (IC501).
YES
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
Is the Collector of Q302 about 2.5 V?
YES
Is the output voltage of BBIC (IC501:CP_VOUT2) 
about 3.0V?
Is the output voltage of BBIC (IC501:CP_VOUT1) 
about 3.0V?
YES
YES
NO
NO
NO
30
KX-TG8551CAB/KXTG8561CAB/KX-TGA855RUB
9.1.1.2.
Handset
Cross Reference:
Power Supply Circuit/Reset Circuit (P.15)
9.1.2.
Check Battery Charge
9.1.2.1.
Base Unit
Cross Reference:
Charge Circuit (P.15)
9.1.2.2.
Handset
Cross Reference:
Check Power (P.29)
Charge Circuit (P.15)
Check Power Supply Circuit/Reset Circuit .
Check BBIC (IC1).
Check F1 is not open.
Check X1.
Is the voltage of  BATT+ 2.3 V more?
Check the battery and around BATT+ and
BATT- are not shorted.
Is the battery inserted BATT+ and BATT-?
Does BBIC (IC1: 10) oscillate at 10.368 MHz?
YES
YES
YES
YES
NO
NO
YES
YES
Is the voltage of +1.8V about 1.8 V?
Is the voltage of CP3V about 3.0 V?
Check BBIC (IC1).
YES
 
Is the voltage of CP_LED about 4.0 V?
(When LED is On)
YES
Is the voltage of CP2.8V about 2.8 V?
NO
NO
NO
Check Charge Circuit of Base Unit.
Check Handset.
Plug in the AC Power source.
Charge Handset on Base Unit.
Is the voltage of two charge contacts about
3 V or more?
OK
NO
Check Charge Contacts at 
Base Unit from mechanical point of view.
YES
Is BBIC (IC1: 33) high at charge state?
Check Charge Circuit.
Check Power of Handset.
Is Check Power OK?
NO
NO
YES
31
KX-TG8551CAB/KXTG8561CAB/KX-TGA855RUB
9.1.2.3.
Charger Unit
Cross Reference:
Power Supply Circuit (P.16)
Check Power Supply Circuit of Charger Unit.
Check Handset.
Plug in the AC Power source.
Charge Handset on Charger Unit.
Is the voltage of two charge contacts about
3 V or more?
OK
NO
Check Charge Contacts at Charger Unit
from mechanical point of view.
YES
32
KX-TG8551CAB/KXTG8561CAB/KX-TGA855RUB
9.1.3.
Check Link
9.1.3.1.
Base Unit
Note:
(*1) Refer to Troubleshooting by Symptom (Base Unit and Charger Unit) (P.41)
Cross Reference:
Check Point (Base Unit) (P.41)
Power Supply Circuit (P.12)
Check around Power Supply Circuit.
Adjust +3.0V voltage to 3.0 V. 
Refer to Check Point...(B).
Does Base Unit make link with normal working
Handset? 
Check around X501 and adjust clock frequency.
Refer to Check Point...(G).
NO
NO
NO (*1)
NO
YES
YES
YES
YES
YES
NO
NO
NO
Replace with a new Circuit Board.
Is the modulation OK? 
Refer to Check Point...(K).
Is the voltage of VBAT about 3.0 V?
Refer to Check Point...(A).
Is there CMD60 (: DECT Tester)?
Does the RF clock (CLK) oscillate at 13.824 MHz in
Base Unit Test Mode?
Refer to Check Point...(G).
Is the voltage of +3.0V about 3.0 V?
YES
Is the NTP value OK? 
Refer to Check Point...(J).
Does Base Unit make link with CMD60 in Base Unit 
Test Mode?
Refer to Check Point...(J).
NO
YES
Base Unit is OK. Check Handset.
YES
YES
Is the Frequency Offset OK? 
Refer to Check Point...(L).
NO
OK
NO
NO
Is the Sensitivity Receiver OK?
Refer to Check Point...(M).
YES
Is the Power RAMP OK?
Refer to Check Point...(N) .
Replace with a new Circuit Board.
Page of 103
Display