DOWNLOAD Panasonic KX-TG8207UAB / KX-TG8207UAJ / KX-TG8207UAM / KX-TG8207UAW / KX-TG8208UAB / KX-TG8208UAW / KX-TGA820RUB / KX-TGA820RUJ / KX-TGA820RUM / KX-TGA820RUW / KX-TGA820UAB / KX-TGA820UAJ / KX-TGA820UAM / KX-TGA820UAW Service Manual ↓ Size: 2.7 MB | Pages: 96 in PDF or view online for FREE

Model
KX-TG8207UAB KX-TG8207UAJ KX-TG8207UAM KX-TG8207UAW KX-TG8208UAB KX-TG8208UAW KX-TGA820RUB KX-TGA820RUJ KX-TGA820RUM KX-TGA820RUW KX-TGA820UAB KX-TGA820UAJ KX-TGA820UAM KX-TGA820UAW
Pages
96
Size
2.7 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / DIGITAL CORDLESS PHONE
File
kx-tg8207uab-kx-tg8207uaj-kx-tg8207uam-kx-tg8207ua.pdf
Date

Panasonic KX-TG8207UAB / KX-TG8207UAJ / KX-TG8207UAM / KX-TG8207UAW / KX-TG8208UAB / KX-TG8208UAW / KX-TGA820RUB / KX-TGA820RUJ / KX-TGA820RUM / KX-TGA820RUW / KX-TGA820UAB / KX-TGA820UAJ / KX-TGA820UAM / KX-TGA820UAW Service Manual ▷ View online

57
KX-TG8207UA/KX-TG8208UA/KX-TGA820RU/KX-TGA820UA
10.2. Assembly Instructions
10.2.1. Fix the LCD to the Main P.C. Board (Handset)
58
KX-TG8207UA/KX-TG8208UA/KX-TGA820RU/KX-TGA820UA
11 Measurements and Adjustments
11.1. The Setting Method of JIG (Base Unit)
11.1.1. Preparation
11.1.1.1. Equipment Required
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm).
Hewlett Packard, 53131A is recommended.
• Digital multi-meter (DMM): It must be able to measure voltage and current.
• Oscilloscope
11.1.1.2. JIG and PC
• Serial JIG
JIG Cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PQZZTG8207UA
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of resis-
tance. Then you can use it as a JIG Cable for both TCD300
and TCD500 series. (It is an upper compatible JIG Cable.)
11.1.2. PC Setting
11.1.2.1. Connections
Connect the AC adaptor to CN2 (base unit).
Connect the JIG Cable GND (black) to J104.
Connect the JIG Cable RX (red) to J103 and TX (yellow) to J102.
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω) New value (kΩ)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
59
KX-TG8207UA/KX-TG8208UA/KX-TGA820RU/KX-TGA820UA
11.1.2.2. Batch file Setting
Note:
• “****” varies depending on the country.
11.1.2.3. Commands
See the table below for frequently used commands.
Command name
Function
Example
rdeeprom
Read the data of EEPROM
Type “rdeeprom 00 00 FF”, and the data from address 
“00 00” to “FF” is read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E 
98” is written.
setfreq
Adjust Frequency of RFIC
Type “setfreq nn”.
hookoff
Off-hook mode on Base
Type “hookoff”.
hookon
On-hook mode on Base
Type “hookon”.
getchk
Read checksum
Type “getchk”.
wreeprom
Write the data of EEPROM
Type “wreeprom 01 23 45”. “01 23” is address and “45” 
is data to be written.
60
KX-TG8207UA/KX-TG8208UA/KX-TGA820RU/KX-TGA820UA
11.2. Adjustment Standard (Base Unit)
When connecting the simulator equipments for checking, please refer to below.
11.2.1. Flow Solder Side View
Note:
(A) - (Q) is referred to Check Point (Base Unit) (P.43)
A
PQUP11527Z
KX-TG7200
KX-TG7220
KX-TG8200
KX-TG8220
KX-TG823
PbF
IC5
IC7
C75
C104
ANT
C74
C63
C92 C94
C51
1
4
8
5
49
1
64
48
33
32
17
16
C6
L1R/TP_RLY4
C5
C8
C12
C61
C59
C166
C57
C165
C54
C69
C68
C70
C50
C164
C52
C136C53
C55
R7
R10
R131
R106
R125
R103
R132
R34
R140
R36
R62
R63
R15
R32
D26
D25
D5
Q8
C65
C137
C56
C7
C67
C72
C163
C125
C101
C102
R102
Q10
A_1
A_2
C118
CHARGE
CHARGE
SPEAKER
SP+
SP-
J104
J102
J103
J101
C73
C60
C1
C62
C25
R133
R1
E
R3
R4
R5
R6
R8
R74
R9
R72
R33
R35
R81
R109
VDD2
VDD3
VDD1
LO
W_RAD
R117
R71
R148
R16
R17
R139
R138
LINE_DC
L1T
L2R
L1R
L2T
L22
L9
TP_RL
Y5
TP_RL
Y1
TP16-sub
TP15
TP15-sub
CLK
TP16
D2
D6
D12
D4
D21
D24
E
D9
Q24
E
DCM
DCP
US1
Q1
Q4
RX
TX
GND
GND
(A
) (
B
) (
C
)
(Q
)
(F
)
(H
)
(P
)
(P
)
(P
)
L1R
L1T
DTMF
T
ester
Call - ID
Sim
ulator
BELL
Sim
ulator
LOOP
Sim
ulator
AF
OSC
AF V
O
LT
METER
OSC
OSC
600
150
SP
ANT
GND
DECT T
ester
CMD60/CTS60
(I
) (
J
) (
K
)
(L
) (
M
) (
N
) (
O
)
DC_IN
Connect A_1 to GND
GND
DC PO
WER
DC 6.5 
V
PC
(D
) (
E
) (
F
) (
G
)
(H
) (
I) (
J
)
Digital
V
olt Meter
GND
LINE_DC
VDD1
VDD3
Digital
V
olt Meter
VDD2
AF V
O
LT
METER
Dumm
y
Handset
AF
OSC
MIC
6.3 V 47 uF
F
requency
Counter
GND
CLK
Digital
V
olt Meter
12
2 W
CHARGE+
CHARGE-
Page of 96
Display