KX-TG7107UAS/KX-TG7107UAT/KX-TG7108UAS/KX-TG7108UAT/KX-TGA710UAS/KX-TGA710UAT
11.3. Adjustment Standard (Charger Unit)
When connecting the simulator equipment for checking, please refer to below.
11.3.1. Flow Solder Side View
Note:
(A) is referred to Check Point (Charger Unit) (P.44)
PQUP11413Z
for_ PQLV30045ZA
BLACK
RED
TP4
TP3
A
TP1
TP2
1
2
PbF
GND (TP4)
TP3
TP1
DC POWER
6.5V
Digital
Volt
Meter
12   /2W
GND (TP2)
(A)
58
KX-TG7107UAS/KX-TG7107UAT/KX-TG7108UAS/KX-TG7108UAT/KX-TGA710UAS/KX-TGA710UAT
11.4. The Setting Method of JIG (Handset)
11.4.1. Preparation
11.4.1.1. Equipment Required
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm).
Hewlett Packard, 53131A is recommended.
• DC power: it must be able to output at least 1 A current under 2.4 V for Handset.
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope
11.4.1.2. JIG and PC
• Serial JIG
JIG Cable: PQZZ1CD300E*
• PC which runs in DOS mode.
• Batch file CD-ROM for setting: PQZZTG7107UA
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of resis-
tance. Then you can use it as a JIG Cable for both TCD300
and TCD500 series. (It is an upper compatible JIG Cable.)
11.4.2. PC Setting
11.4.2.1. Connections
Connect the DC Power or Battery to J1 and J2 (Handset).
Connect the JIG cable GND (black).
Connect the JIG cable UTX (yellow) and URX (red).
Note:
*: Com port names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω) New  value  (kΩ)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
59
KX-TG7107UAS/KX-TG7107UAT/KX-TG7108UAS/KX-TG7108UAT/KX-TGA710UAS/KX-TGA710UAT
11.4.2.2. Batch file Settings
Note:
• “*****” varies depending on the country.
11.4.2.3. Commands
See the table below for frequently used commands.
Command name
Function
Example
rdeeprom
Read the data of EEPROM
Type “rdeeprom 00 00 FF”, and the data from address
“00 00” to “FF” is read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E
98” is written.
setfreq
Adjust Frequency of RFIC
Type “setfreq nn”.
getchk
Read checksum
Type “getchk”.
wreeprom
Write the data of EEPROM
Type “wreeprom 01 23 45”. “01 23” is address and “45”
is data to be written.
60
K
X
-T
G7
107U
A
S
/K
X
-T
G
7107U
A
T
/K
X
-T
G
710
8U
A
S
/K
X
-T
G
710
8
U
A
T
/K
X
-T
GA
710U
A
S
/K
X
-T
G
A
710
U
A
T
11
.5
.
A
djustm
ent S
tan
dard 
(H
an
dset
)
Wh
en c
o
nnec
ting t
he s
im
u
la
to
r eq
uip
m
en
t f
o
r c
hec
ki
ng
, pl
eas
e r
e
fer 
to b
e
lo
w
.
11
.5
.1
.
C
ompone
n
t V
iew
Note
:
(A
) - (
T
) is
 ref
e
rred
 to 
C
h
ec
k Poi
n
t (H
an
dse
t) (P
.45)
PbF
L1
C38
R11
R12
C15
R8
Q5
Q9
R7
R5
R6
R21
R62 R61
R47
R45
C14
C12
C33
L4
L5
F1
R24
C32
R16
R23
C96
C97
C93
R100
R66
R102
Q7
R92
C94
Q8
Q12
Q11
Q10
Q1
S
E
D1
Q2
C2
C37
Q3
C1
C70
C54
C55
C50
C51
R53
C66
C67
ANT
ANT1
C72
R63
R64
R65
R40
R41
R42
R101
R99
C7
CHARGE-
CHARGE+
MIC
TP20
TP21
TP23
TP22
J3
J1
D8
Q4
D6
D7
C18
C8
C21
C26
C22
C39
C23
GND
BAT
C5
C4
C9
C10
JTAG
R44
R91
C99
R96
C36
C98
C100
SP
C60
C59
11
0
16
17
11
32
27
26
C61
C62
C56
C53
C52
R52
C58
R51
CLK
CLK_G
C57
C3
POWER
VDD3
VDD1
VDD2
R43
R98
R25
C11
R97
R22
C35
C92
R46
J2
J4
URX
BATT-
BATT+
UTX
C91
C6
C19
R2
R1
D4
D5
C71
SP_TEST1
R
EV
_TES
T2
R
EV
_TES
T1
SP_TEST2
C25
C95
C24
L7
L6
R13
R19
REV
IC1
IC3
KX-TG7100/TGA710
X1
IC4
PQUP11407Z
1
100
25
26
50
76
51
75
1
4
8
5
A
R104
R103
OSC
AF VOLT
METER
LOOP
Simulator
Frequency
Counter
Dummy Base
Unit
GND
GND
GND
CLK
VDD1
VDD2
VDD3
UTX
URX
150
56
56
SP+
REV-
REV+
SP-
8
6.3V 47uF
1uF
AF
GENERATOR
TP22
TP21
TP20
DC POWER
2.00-2.25V
(When at BATT LOW)
Oscilloscope
AF VOLT
METER
A
B
1
POWER KEY
DC POWER
2.30-2.60V
2.7V
Zener
PC
Digital
Volt Meter
AF
OSC
DC
6.5V
Current
Probe
Oscilloscope
TP23
MIC-
MIC+
600
GND
ANT
DECT Tester
CMD60
(S)
(F) (G) (H) (I)
(A) (D) (E) (H) (I) (J) (K) (Q)
(A) (B) (C)
(J)
(S) (T)
(S) (T)
(K) (L) (M) (N) 
(O) (P) (Q) (R)