45
KX-TG6511CAT/KX-TG6511CAM/KX-TG6512CAT/KX-TG6512CAM/KX-TGA650RUT/KX-TGA650RUM/KX-TGA651RUT/KX-TGA651RUM
10.1.3. Charger Unit
46
KX-TG6511CAT/KX-TG6511CAM/KX-TG6512CAT/KX-TG6512CAM/KX-TGA650RUT/KX-TGA650RUM/KX-TGA651RUT/KX-TGA651RUM
10.2. How to Replace the Handset LCD
Note: 
The illustrations are simplified in this page.
They may differ from the actual product.
47
KX-TG6511CAT/KX-TG6511CAM/KX-TG6512CAT/KX-TG6512CAM/KX-TGA650RUT/KX-TGA650RUM/KX-TGA651RUT/KX-TGA651RUM
11 Measurements and Adjustments
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in 
 Troubleshooting Guide (P.23)
11.1. Equipment Required
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
Hewlett Packard, 53131A is recommended.
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
This equipment may be useful in order to precisely adjust like a mass production.
11.2. The Setting Method of JIG (Base Unit)
This section explains the PC setting to use command required in Check Point (Base Unit)(P.35).
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PNZZTG6511CA
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
11.2.1. Connections
 Connect the AC adaptor to DC-JACK (base unit).
 Connect the JIG Cable GND (black) to GND.
 Connect the JIG Cable RX (red) to URX and TX (yellow) to UTX.
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω) New value (kΩ)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
48
KX-TG6511CAT/KX-TG6511CAM/KX-TG6512CAT/KX-TG6512CAM/KX-TGA650RUT/KX-TGA650RUM/KX-TGA651RUT/KX-TGA651RUM
11.2.2. How to install Batch file  into P.C.
Note:
• “*****” varies depending on the country or models.
11.2.3. Commands
See the table below for frequently used commands.
Command name
Function
Example
rdeeprom
Read the data of EEPROM
Type “rdeeprom 00 00 FF”, and the data from address 
“00 00” to “FF” is read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E 
98” is written.
hookoff
Off-hook mode on Base
Type “hookoff”.
hookon
On-hook mode on Base
Type “hookon”.
getchk
Read checksum
Type “getchk”.
wreeprom
Write the data of EEPROM
Type “wreeprom 01 23 45”. “01 23” is address and “45” 
is data to be written.
Page of 82