Panasonic KX-TG6511CAT / KX-TG6511CAM / KX-TG6512CAT / KX-TG6512CAM / KX-TGA650RUT / KX-TGA650RUM / KX-TGA651RUT / KX-TGA651RUM Service Manual ▷ View online
29
KX-TG6511CAT/KX-TG6511CAM/KX-TG6512CAT/KX-TG6512CAM/KX-TGA650RUT/KX-TGA650RUM/KX-TGA651RUT/KX-TGA651RUM
Cross Reference:
Check Point (Handset) (P.39)
30
KX-TG6511CAT/KX-TG6511CAM/KX-TG6512CAT/KX-TG6512CAM/KX-TGA650RUT/KX-TGA650RUM/KX-TGA651RUT/KX-TGA651RUM
9.1.4.
Check the RF part
9.1.4.1.
Finding out the Defective part
After All the Checkings or Repairing
1. Re-register the checked Handset to the checked Base Unit, and Regular HS to Regular BU.
Note:
If you need to register a handset, refer to Registering a Handset to a Base Unit in the Operating Instructions.
31
KX-TG6511CAT/KX-TG6511CAM/KX-TG6512CAT/KX-TG6512CAM/KX-TGA650RUT/KX-TGA650RUM/KX-TGA651RUT/KX-TGA651RUM
9.1.4.2.
RF Check Flowchart
Each item (1 ~ 3) of RF Check Flowchart corresponds to Check Table for RF part (P.32).
Please refer to the each item.
Please refer to the each item.
Note:
(*1) Base unit - refer to (G) of Check Point (Base Unit) (P.35)
Handset - refer to (H) of Check Point (Handset) (P.39)
Handset - refer to (H) of Check Point (Handset) (P.39)
32
KX-TG6511CAT/KX-TG6511CAM/KX-TG6512CAT/KX-TG6512CAM/KX-TGA650RUT/KX-TGA650RUM/KX-TGA651RUT/KX-TGA651RUM
9.1.4.3.
Check Table for RF part
Note:
(*1) Refer to Adjustment Standard (Base Unit) (P.49)
(*2) Refer to Adjustment Standard (Handset) (P.53)
(*2) Refer to Adjustment Standard (Handset) (P.53)
No.
Item
BU (Base Unit) Check
HS (Handset) Check
1
Link Confirmation Normal
HS, BU Mode: [Normal mode]
1. Register Regular HS to BU (to be
checked).
2. Press [Talk] key of the Regular HS to
establish link.
1. Register HS (to be checked) to Regular
BU.
2. Press [Talk] key of the HS to establish link.
2
X’tal Frequency confirmation
1. Check X’tal Frequency. (*1)
(10.368 MHz ± 100 Hz)
1. Check X’tal Frequency. (*2)
(10.368 MHz ±100Hz)
3
Range Confirmation Normal
HS, BU Mode: [Normal mode]
1. Register Regular HS to BU (to be
checked).
2. Press [Talk] key of the Regular HS to
establish link.
3. Compare the range of the BU (being
checked) with that of the Regular BU.
1. Register HS (to be checked) to Regular
BU.
2. Press [Talk] key of the HS to establish link.
3. Compare the range of the HS (being
3. Compare the range of the HS (being
checked) with that of the Regular HS.
Click on the first or last page to see other KX-TG6511CAT / KX-TG6511CAM / KX-TG6512CAT / KX-TG6512CAM / KX-TGA650RUT / KX-TGA650RUM / KX-TGA651RUT / KX-TGA651RUM service manuals if exist.