57
KX-TG6461RUT/KX-TGA641RUT
11.5.2. How to install Batch file into P.C.
Note:
• “*****” varies depending on the country or models.
11.5.3. Commands
See the table below for frequently used commands.
Command name
Function
Example
rdeeprom
Read the data of FLASH
Type “rdeeprom 00 00 FF”, and the data from address
“00 00” to “FF” is read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E
98” is written.
setfreq
Adjust Frequency of RFIC
Type “setfreq nn”.
getchk
Read checksum
Type “getchk”.
wreeprom
Write the data of FLASH
Type “wreeprom 01 23 45”. “01 23” is address and “45”
is data to be written.
58
KX-TG6461RUT/KX-TGA641RUT
11.6. Adjustment Standard (Cordless Handset)
When connecting the simulator equipments for checking, please refer to below.
11.6.1. Component View
Note:
(A) - (R) is referred to Check Point (Cordless Handset) (P.42)
B
PbF
PNLB1103Z
KX-TGA641 EUDECT
KX-TGA106 USDECT
RECEIVER
CP4.0V
CP3.0V
X_CLK
IC1
1.8V
POWER
E
E
E
E
BATT+
BATT-
BLACK
BLACK (EU)
RED
JTAG
RED (EU)
WHITE (EU)
BLUE (US)
TP_ANT1
X1
1
2
5
1
4
3
4
8
5
20
21
1
1
80
61
60
40
41
SP-PHONE_SPEAKER
UTX
URX
GND
CHG (-)
CHG (+)
MIC +
MIC -
MIC
BA
T
MIC+
MIC-
C138
C139
C70 C152 C71
C863 C864
C837
C811
C813
L802
C804
C802
C814
C834
C44
C73
C79
C72
C78
C2
C1
C6
C10
C48
C43
C7
C38
C332
C331
C51
C55
C53
C52
C54
C40
C172
C86
C113
C4
C77
C147
C35
C76
R807
R806
D
A
801
R805 R802
R203
R208
R209
R310
R309
R308
R63
R225
R252
R251
R64
R330
R40
R331
R41
R42
R248
R249
R301
R305
R302
R303
R300
R304
R2
R73
R311
R30
R74
R31
R7
R6
R4
R45
L804
L4
L8
L5
RA2
RA4
RA61
D22
D21
D13
D14
D1
D7
D4
D3
Q11
Q12
Q9
C862
C105
C187
C186
C107
C106
C103
C104
C580
C175
C860
C182
C859
C36
C45
C820
C825
C861
C808
C809
C810
C805
C806
C812
C827
L801
L803
C803
C819
C826
C822
TEST
C46
C33
C
109
C111
C16
C12
C14
C97
C96
C184
C18
C47
C17
Q2
R215
C41
C13
C11
C188
C50
C49
C108
C39
C110
C127
C128
C83
C185
C82
C15
C150
C3
F1
C121
C74
C75
C5
R51
R50
R578
R52
R53
R54
R55
R808
Q10
R801
R804
R803
R66
R65
R25
R27
R28
R332
R22
R33
R35
R12
R34
R32
R100
R307
CN4
R20
R306
R8
R312
R313
L9
L3
L71
L74
L73
L72
IC3
IC801
RA1
D8
Q7
Q4
OSC
AF V
O
LT
METER
LOOP
Sim
ulator
Dumm
y Base
Unit
6.3 
V 47  F
6.3 
V 47  F
AF
GENERA
T
O
R
(O)
(D),(E),(F),(G)
(A),(B),(C),(F),(G),(H),(I)
(A),(Q),(R)
(H)
(I),(J),(K),(L),(M),(N)
(O),(P)
(O),(P)
DC
6.5V
DC PO
WER
2.30-2.60V
DC PO
WER
2.00-2.25V
GND
Digital
V
olt Meter
UTX
URX
GND
PC
GND
CLK
F
requency
Counter
2.7 V
Zener
AF
OSC
MIC-
MIC+
+
+
600
100
GND
ANT
DECT T
ester
CMD60
(at batter
y lo
w)
PO
WER KEY
150
56
56
SP+
REV-
REV+
SP-
8
1  F
AF V
O
LT
METER
Oscilloscope
A
B
1
22pF
Current
Probe
Oscilloscope
1.8V
CP 4.0V
CP 3.0V
59
KX-TG6461RUT/KX-TGA641RUT
11.7. Things to Do after Replacing IC or X'tal
If repairing or replacing BBIC (FLASH type), EEPROM and X'tal, it is necessary  to download the required data such as Program-
ming data or adjustment data, etc in memory.
The set doesn't operate if it is not executed.
11.7.1. How to download the data
11.7.1.1. Base Unit
First, operate the PC setting according to The Setting Method of JIG (Base Unit)(P.52).
Then download the appropriate data according to the following procedures.
Note:
(*1) XX: country code YY: revision number, ZZ: voice prompt
“XX”, “YY” and “ZZ” vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting
Method of JIG (Base Unit)
 (P.52).
(*2) Refer to Check Point (Base Unit) (P.38)
Items
How to download/Required adjustment
BBIC (IC501)
Programming data is stored in memory.
1) Make sure to connect the JIG cable, then disconnect the DC 
Power in order to download the data.
2) Execute the command “flw480 *********.hex”.
3) Connect the DC Power.
4) Press the PC Enter key once.
5) After a few minutes, “Successful upgrade” is displayed on the 
PC indicating downloading has finished.
6) Detach the JIG cable, then disconnect the DC Power.
7) Connect the DC Power.
8) Connect the JIG cable again, and execute the command 
“getchk”, then confirm the checksum value is correct.
• If the downloading fails, start again from step 1).
9) Default batch file: Execute the command “default.bat”.
10) Country version batch file: Execute the command 
“TG6461XXrevYY.bat”. (*1)
11) Clock adjustment: Refer to Check Point (H). (*2)
EEPROM (IC561)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Change the address “0000” of EEPROM to “55” to download  
the data.
2) Default batch file: Execute the command “default.bat”.
3) Country version batch file: Execute the command 
“TG6461XXrevYY.bat”. (*1)
4) Clock adjustment: Refer to Check Point (H). (*2)
FLASH (IC541)
Voice prompt data is stored in memory.
(vary depending on country version)
1) Wait more than 15 seconds after connecting the JIG Cable.
2) Execute the command "VPDL2009 -57600 ZZ.bin"(*1).
3) Wait until “VP file transfer complete” is displayed on the P.C.
(writing time: aprox. About 1 min)
4) Detach the JIG cable to disconnect DC Power.
Then reconnect the DC Power and confirm whether the down-
load is successfully completed. 
X'tal (X511)
System clock
Clock adjustment data is in EEPROM, adjust the data again
after replacing it.
1) Refer to Check Point (H). (*2)
60
KX-TG6461RUT/KX-TGA641RUT
11.7.1.2. Cordless Handset
First, operate the PC setting according to The Setting Method of JIG (Cordless Handset)(P.56).
Then download the appropriate data according to the following procedures.
Note:
(*3) XX: country code YY: revision number
“XX” and “YY” varies depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting
Method of JIG (Cordless Handset)
 (P.56).
(*4) Refer to Check Point (Cordless Handset) (P.42)
Items
How to download/Required adjustment
BBIC (FLASH type)
(IC1)
Programming data is stored in memory.
1) Make sure to connect the JIG cable, then disconnect the DC
Power in order to download the data.
2) Execute the command “flw480 *********.hex”.
3) Connect the DC Power.
4) Press and hold the cordless handset Power key.
5) While holding down the cordless handset Power key, press
the PC Enter key once.
6) After a few minutes, “Successful upgrade” is displayed  on
the PC indicating downloading has finished.
7) Detach the JIG cable, then press the cordless handset
Power key to turn it on.
8) Connect the JIG cable again, and execute the command
"getchk”, then confirm the checksum value is correct.
• If the downloading fails, start again from step 1).
9) Default batch file: Execute the command “default.bat”.
10) Default batch file (remaining): Execute the command
“TGA641RU_DEFrevYY.bat”. (*3).
11) Country version batch file: Execute the command
“TGA641XXrevYY.bat”. (*3).
12) Clock adjustment: Refer to Check Point (H). (*4).
13) 1.8 V setting and battery low detection: Refer to Check
Point (A), (F) and (G). (*4).
EEPROM (IC3)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Default batch file: Execute the command “default.bat”.
2) Default batch file (remaining): Execute the command 
“TGA641RU_DEFrevYY.bat”. (*3)
3) Country version batch file: Execute the command 
“TGA641XXrevYY.bat”. (*3)
4) Clock adjustment: Refer to Check Point (J). (*4)
5) 1.8 V setting and battery low detection: Refer to Check Point 
(A), (F) and (G). (*4)
X'tal (X1)
System clock
Clock  adjustment  data is in EEPROM, adjust the data again
after replacing it.
1) Refer to Check Point (H). (*4)
Page of 96
Display

Click on the first or last page to see other KX-TG6461RUT / KX-TGA641RUT service manuals if exist.