DOWNLOAD Panasonic KX-TG1411RUM / KX-TG1411RUT / KX-TG1412RU1 / KX-TGA141RUM / KX-TGA141RUT Service Manual ↓ Size: 1.52 MB | Pages: 60 in PDF or view online for FREE

Model
KX-TG1411RUM KX-TG1411RUT KX-TG1412RU1 KX-TGA141RUM KX-TGA141RUT
Pages
60
Size
1.52 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / DIGITAL CORDLESS PHONE
File
kx-tg1411rum-kx-tg1411rut-kx-tg1412ru1-kx-tga141ru.pdf
Date

Panasonic KX-TG1411RUM / KX-TG1411RUT / KX-TG1412RU1 / KX-TGA141RUM / KX-TGA141RUT Service Manual ▷ View online

37
KX-TG1411RUM/KX-TG1411RUT/KX-TG1412RU1/KX-TGA141RUM/KX-TGA141RUT
11.5. The Setting Method of JIG (Handset)
This section explains the PC setting to use command required in Check Point (Handset) (P.27).
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PNZZTG1411RU
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of resis-
tance. Then you can use it as a JIG Cable for both TCD300
and TCD500 series. (It is an upper compatible JIG Cable.)
11.5.1. Connections
Connect the DC Power or Battery to BATTERY(+) and BATTERY(-) (Handset).
Serial JIG to the Serial Port of PC.
Connect the Clip cable GND.
Connect the Clip cable UTX and URX.
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω) New value (kΩ)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
38
KX-TG1411RUM/KX-TG1411RUT/KX-TG1412RU1/KX-TGA141RUM/KX-TGA141RUT
11.5.2. How to install Batch file into P.C
Note:
• “*****” varies depending on the country or models.
11.5.3. Commands
See the table below for frequently used commands.
Command name
Function
Example
rdeeprom
Read the data of EEPROM
Type “rdeeprom 00 00 FF”, and the data from address “00 00” to “FF” is
read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E 98” is written.
setfreq
adjust Frequency of RFIC
Type “setfreq nn nn”.
Getchk
Read checksum
Type “getchk”.
Wreeprom
write eeprom
Type “wreeprom 01 23 45”. “01 23” is address and “45” is data to be written.
39
KX-TG1411RUM/KX-TG1411RUT/KX-TG1412RU1/KX-TGA141RUM/KX-TGA141RUT
11.6. Adjustment Standard (Handset)
When connecting the Simulator Equipments for checking, please refer to below.
11.6.1. Component View
Note:
(A) - (O) is referred to Check Point (Handset) (P.27)
C155
C112
C140
C146
C148
C102
C107
C142
C100
MIC+
MIC-
C131
RXD
TXD
GND
VBAT
C123
C127
C119
C130
C186
C129
C128
C111
C108
C110
C104
C103
C122
C114
C150
C152
C154
R102
R101
R123
R121
P1.0
BAT
3.3V
R115
R117
R112
L104
L103
1
8
5
4
IC101
IC102
IC103
D104
D106
D105
ANT
ANT1
BZ2
REV
D103
D102
Q104
Q105
Q103
C116
C115
C147
C124
C120
C141
1
C134
C133
C106
C117
C143
C105
C101
C144
C125
C118
C109
C121
C126
C113
C153
C151
C149
C132
R105
R108
R230
R103
R106
R104
R122
R107
R116
R113
R114
X101
D107
Q102
Q101
A
TG131EXR
PQUP11567Z
PbF
BATT Low Check
2.3V
DC Power
2.30V - 2.60V
Serial JIG
PC
4.7k
600
REV+
REV-
ANT
GND
DECT Tester
CMD60
AF VOLT
METER
(O)
(O)
(O)
(H)
(B)
(C)
(I), (J), (K), (L), (M), (N)
(A), (F), (G)
(D), (E)
(O)
LOOP
Simulator
Dummy Base
Unit
AF
OSC
AF
Volt Meter
150
GND
GND
GND
BAT
Battery +
Battery -
P1.0
TP23
TP17
TP22
TP6
TP5
MIC+
MIC-
TXD
RXD
Frequency
Counter
3.3V
Digital
Volt Meter
Power Key
TALK Key
DC
6V
AF
Generator
6.3 V 47   F 
40
KX-TG1411RUM/KX-TG1411RUT/KX-TG1412RU1/KX-TGA141RUM/KX-TGA141RUT
11.7. Things to Do after Replacing IC 
If repairing or replacing BBIC (FLASH type), EEPROM , it is necessary  to download the required data such as Programming
data or adjustment data, etc in memory.
The set doesn't operate if it is not executed.
11.7.1. How to download the data
11.7.1.1. Base Unit
First, operate the PC setting according to The Setting Method of JIG (Base Unit) (P.33).
Then download the appropriate data according to the following procedures.
Note:
(*1) Refer to Check Point (Base Unit) (P.24)
(*2) XX: country code, YY: revision number
“XX” and “YY” vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting
Method of JIG (Base Unit)
 (P.33).
11.7.1.2. Handset
First, operate the PC setting according to The Setting Method of JIG (Handset) (P.37).
Then download the appropriate data according to the following procedures.
Note:
(*3) Refer to Check Point (Handset) (P.27)
(*4) XX: country code, YY: revision number
“XX” and “YY” vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting
Method of JIG (Handset)
 (P.37).
IC
How to download/Required adjustment
BBIC
Programming data is stored in memory.
1) Clock adjustment: Refer to Check Point (E). (*1)
EEPROM Adjusted parameter data is stored in memory.
(country version batch file, default batch file, etc.)
1) Default batch file: Execute the command “Default4KB”.
2) Country version batch file: Execute the command 
“1311XXvYY.bat”. (*2)     
3) Clock adjustment: Refer to Check Point (E). (*1)
IC
How to download/Required adjustment
BBIC
Programming data is stored in memory.
1) Clock adjustment: Refer to Check Point (H). (*3)
2) 4.0 V setting and battery low detection: Refer to Check Point (A),
(F) and (G). (*3)
EEPROM Adjusted parameter data is stored in memory.
(country version batch file, default batch file, etc.)
1) Default batch file: Execute the command “Default”.
2) Melody Initialize batch file; Execute the Command “DB3MZA”.
3) Country version batch file: Execute the command 
“131XXvYY.bat”. (*4)
4) Clock adjustment: Refer to Check Point (H). (*3)
5) 4.0 V setting and battery low detection: Refer to Check Point (A),
(F) and (G). (*3)
Page of 60
Display