65
KX-TCD951GB/KX-TCD955GC
If FFh then 00h will be used which corresponds to the
"old" mute algorithm. In order to enable any settings the
unused bits should be set to zero.
5E-60
FF..FF
Reserved
Reserved for BMC
61
01
TalkModeDisplay
0=Nothing, 1=BaseNo, 2=HsNo
Sound & Volume Settings (
User Specific)
62
01
IntRingSound
Selected Internal Ringesound (1-5)
63
01
ExtRingSound
Selected External Ringsound (1-5)
64
01
CallBackRingSound
Selected Callback Ringsound (1-5)
65
03
RingerVolumen
Ring sound volume (low = 0 - high = 6)
66
81
Config00
Bit 0: Key beep on/off
Bit 1: Barring on/off
Bit 2: PowerOn Pincode on/off
Bit 3: Handset progmode pincode on/off
Bit 4: Answering incoming calls (lifting out of charger
on/off)
Bit 5: Baby Call on/off
Bit 6: not used
Bit 7: not used
67
8D
Config01
Bit 0-6: Reserved
Bit 7: Testmode allowed(1)/ not allowed(0)
68
05
MinAudioVolume
Minimum audio Level (range 0 -9)
69
03
MedAudioVolume
Medium audio Level (range 0 - 9)
6A
01
MaxAudioVolume
Maximum audio Level (range 0 -9)
6B
02
VolumeStep
Selected Level (range 1 - 3)
6C
05
VolMaxAnalogOffset
Offset for analog adjustment at volume max
offset in setps = VolMaxAnalogOffset- 07(hex)
6D
00
DefaultLanguage
6E
00
Language
6F
FF
KME
AdpcmOffsetVolume
70
00
CountryCode
71
00
Option
Option of function
Bit 0: Charge Menu on/off 0:off 1:on
bit 1: not use
bit 2: not use
bit 3: not use
bit 4: not use
bit 5: not use
bit 6: not use
bit 7: not use
72-142
FF
KME DirectoryFAT
FAT information of directory numbers
143-163
FF
Unused
Free block
164
00
RegConfigSwitch
byte 24 active
165-16F
00
RegConfigParam
Reg store when active
Battery & Charger Control
170
49
LowVoltage
Number of ADC step for battery low
171
40
NoVoltage
Number of ADC step for batter empty
172
D9
MaxVoltage
Number of ADC step for battery max voltage
173
FF
DeltaVoltage
Number of ADC step for difference between battery
voltage at charge and no charge
174
06
StbyCurrent
Standby current compsumption
175
06
UnlockCurrent
Unlock current compsumption
176
37
MacCurrent
Current compsumtion when a MAC connection is
established
66
KX-TCD951GB/KX-TCD955GC
177
1B
ChargeCurrent
Charge current when charging the battery.
178
4B
TopLimit_LoCap
Percent of max battery capacity with fast charge
179
4B
TopCycle_LoCap
Top charge cycle, MSB (on period), LSB (off period)
17A
1F
MaintainCycle_LoCap
Maintain charge cycle, MSB (on period), LSB (off
period)
17B
00
BatteryCapacity_lsb
Bat. capacity,  the battery can be brought up to
[mAh*100]
17C
00
BatteryCapacity_msb
Bat. capacity,  the battery can be brought up to
[mAh*100]
17D
A8
MaxCapacity_lsb
_LoCap
Max. capacity,  the battery can be brought up to
[mAh*100]
17E
61
MaxCapacity_msb
_LoCap
Max. capacity,  the battery can be brought up to
[mAh*100]
17F
FF
NegativeDeltaVoltage
_LoCap
180
FF
MinimumTemperature
181
00
MaximumTemperature
182
FF
PowerMark
00= normal powerdown, FF=unauthorized powerdown.
183
00
CapacityAlarm
184
00
BatterySelection
Bit 0: 0= Select LowCapacity Battery
          1= Select HighCapacity Battery
Bit 1-7: not used
185
4E
ChargeCurrent_HiCap
Charge current when charging the battery.
186
49
TopLimit_HiCap
Percent of max battery capacity with fast charge
187
4B
TopCycle_HiCap
Top charge cycle, MSB (on period), LSB (off period)
188
29
MaintainCycle_HiCap
Maintain charge cycle, MSB (on period), LSB (off
period)
189
D8
MaxCapacity_lsb
_HiCap
Max. capacity,  the battery can be brought up to
[mAh*100]
18A
D6
MaxCapacity_msb
_HiCap
Max. capacity,  the battery can be brought up to
[mAh*100]
18B
FF
NegativeDeltaVoltage
_HiCap
18C-1C6
FF
Unused
Free block
1C7-1CF
FF
PrivateRingInfo
Data area for costumer usage
1D0-1EA
FF
Unused
Free block
1EB-1FF
FF
ProcEepAddr
Reserved for Production use
Short Number Storage
200-304
FF
ShortNumberMem
Short number storage for 20 numbers each with 24
digits
Redial Stack Storage
305-386
FF
RedialStackMem
Redial stack storage for 10 numbers each with 24 digits
CLIP Stack storage
387-408
FF
CLIPMemory
CLIP stack memory for 10 numbers each with 24 digits.
1
Baby Call Number Storage
409-415
FF
BabyCallMemory
Baby Call Memory. 1 number with 24 digits
First byte is the no. of digits and the last 12 bytes is the
actual no. (right aligned)
Miscellaneous Administrative Storage
416-41F
FF
RedialFAT
Redial Stack Information
420-429
FF
CLIPFat
CLIP stack Information
42A-4FF
FF
Unused
Free Block
                                                  
67
KX-TCD951GB/KX-TCD955GC
GAP Subscription Data
500-77F
00
SubscriptionData
GAP Subscription Data. Storage for 8 subscriptions
each with 80 bytes.
Miscellaneous GAP Data
780-784
00
Ipei
International Portable Part Equipment Identities. A
concatenation of an EMC and a unique 20 bit Serial
Number.
785
00
SubNo
Pointer to selected Subscription (0 - 7)
786-7FF
FF
Unused
Free block
68
KX-TCD951GB/KX-TCD955GC
1
 CLIP is at present only able to show the number of an intercom connection as there is no hardware to
support showing external line numbers.
3.1.2 Overview of individual hardware specific settings for the Handset
Address
Name
Description
12-14
Rssi Compesation
Adjustment parameter (Rssi)
4B
Frequency
Adjustment parameter (Crystal frequency)
4F
BMC. Comperator
Adjustment parameter (Data Comperator)
51
BMC. Vol Flt M
Adjustment parameter (Modulation)
54
BMC. Lsr Mic Gain
Adjustment parameter (Audio gain)
170
Low Voltage
Adjustment parameter (ADC step for battery low)
171
No Voltage
Adjustment parameter (ADC step for battery empty)
780-784
Ipei
IPEI (serial number)
Page of 78
Display