A
Addddrreessss
D
Deeffaauulltt
N
Naam
mee
C
Coouunnttrryy
S
Seettttiinngg
T
Tyyppee
D
Deessccrriippttiioonn
0A2F-30
00 28
DtasDet.C_ATD1
-
D
DTAS detection C_ATD1
refer to data sheet T67DSP-FPV2xD5-7600 for
details
0A31-32
E8 FE
DtasDet.C_ATD2
-
D
DTAS detection C_ATD2
0A33-34
B0 C2
DtasDet.C_ATD3
-
D
DTAS detection C_ATD3
0A35-36
A1 98
DtasDet.C_ATD4
-
D
DTAS detection C_ATD4
0A37-38
00 29
CasDet.C_ATD1
-
D
CAS detection C_ATD1
refer to data sheet T67DSP-FPV2xD5-7600 for
details
0A39-3A
E8 FE
CasDet.C_ATD2
-
D
CAS detection C_ATD2
0A3B-3C
B0 C2
CasDet.C_ATD3
-
D
CAS detection C_ATD3
0A3D-3E
A1 9B
CasDet.C_ATD4
-
D
CAS detection C_ATD4
0A3F-40
CC 5B
ProgressDet.C_CPT1
-
d
Progress tone detection C_CPT1
FC=438Hz
refer to data sheet T67DSP-FPV2xD5-7600 for
details
0A41-42
92 31
ProgressDet.C_CPT2
-
d
Progress tone detection C_CPT2
BP-width = 535hz
0A43-44
92 31
ProgressDet.C_CPT3
-
d
Progress tone detection C_CPT3
BS-width = 535hz
0A45-46
41 10
ProgressDet.C_CPT4
-
d
Progress tone detection C_CPT4
LIM_T = -84dB
0A47-48
0A 05
ProgressDet.C_CPT5
-
d
Progress tone detection C_CPT5
0A49-4A
F4 38
ProgressDet.C_CPT6
-
d
Progress tone detection C_CPT6
0A4B-4C
7F 03
ProgressDet.C_CPT7
-
d
Progress tone detection C_CPT7
0A4D
3C
AGC.Vmax
-
D
Upper VAGC limit. AGC adjustment is carried out
from AGC.Vmin to AGC.Vmax. Unit: ADC steps.
0A4E
28
AGC.Vmin
-
d
Lower VAGC limit.Unit: ADC steps.
0A4F
02
AGC.VHysteresis
-
d
VAGC hysteresis Unit: ADC steps.
0A50
2D
AGC.Steps
-
d
SLR and RLR steps
Bit0-2: SLR steps, range 2-7 (0 = disable SLR AGC)
Bit 5-3: RLR steps, range 2-7 (0 = disable RLR AGC)
Bit 6-7: Not used
Defaults to 5 SLR steps and 5 RLR steps.
0A51
6F
MeterPulse.MPC
-
D
Meter Pulse detection
Bit 0..1: Hysteresis, 11=+/-0.5LSB
Bit 2..3: MPCGain 11=gain is 8
Bit 4: F12Khz, 1=12Khz, 0=16Khz
Bit 5: GGISel, 1=use tolerant circuit, 0=use in-tolerant
circuit
Bit6: MPC input ADREF offset - 0=disable, 1=enable
Bit 7: LS, 1=use level-shifter, 0=disable level-shifter
Refer to description of registers: MPCCTR,
METPULSE
0A52
00
MeterPulse.MpcMv
-
d
Meter Pulse detection , mean value of comparator
Refer to description of registers: MPCMV
0A53
FF
MeterPulse.Reserved
-
D
Meter Pulse detection , reserved
0A54
00
PlugD.Enable
-
D
Bit 0: Line reversal offhook, 1=enable, 0=disable
Bit 1..7: not used
0A55
0A
PlugD.IntegrateTime
-
D
Integrate-time for detecting plug-in/out, line-reversal,
and parallel-offhook. If FFh plug/pol detection is
completely disabled.
Unit : 10 ms, defaults to 100 ms
0A56
20
PlugD.LvIdleAvgCnt
-
D
Number of samples to use when finding the idle line-
voltage LvIdle.
Unit : samples (rate 1/10ms), defaults to 32
0A57
0A
PlugD.LvDetThresh
-
d
Minimum Va/Vb voltage level in order to detect line-
voltage. Used for plug-in/plug-out detection.
Unit : adc-steps
0A58
5B
PlugD.LrDetThresh
-
d
Minimum Va/Vb voltage level in order to detect Va/Vb
polarity.
Unit: adc-steps
0A59
FF
PlugD.ParVdeltaMinOnh
-
d
Minimum voltage difference (deviation from LvIdle) in
order to detect parallel inuse during on-hook.
Unit: adc-steps, defaults to disabled
0A5A
FF
PlugD. ParVdeltaMinOfh
-
d
Minimum voltage difference (deviation from LvIdle) in
order to detect parallel inuse during off-hook.
Unit: adc-steps, defaults to disabled
0A5B-5C
FF..FF
PlugD.Unused
-
D
Reserved
0A5D-6F
FF..FF
Reserved
-
-
Reserved by the line driver
53
KX-TCD650RUC / KX-TCD650RUF
1166..33..1133..  FFrreeee bblloocckk 22
A
Addddrreessss
D
Deeffaauulltt
N
Naam
mee
C
Coouunnttrryy
S
Seettttiinngg
T
Tyyppee
D
Deessccrriippttiioonn
0A70-0A8F
-
Free block
-
-
Free Block , previously reserved for KME
0A90-0A9F
-
Free block
-
-
Free Block , previously reserved for KME
1166..33..1144..  S
SppeeaakkeerrP
Phhoonnee
A
Addddrreessss
D
Deeffaauulltt
N
Naam
mee
C
Coouunnttrryy
S
Seettttiinngg
T
Tyyppee
D
Deessccrriippttiioonn
0AA0-AAF
-
Reserved
-
-
Reserved for speakerphone
1166..33..1155..  TTA
AD
D sseettttiinnggss
A
Addddrreessss
D
Deeffaauulltt
N
Naam
mee
C
Coouunnttrryy
S
Seettttiinngg
T
Tyyppee
D
Deessccrriippttiioonn
0AB0-ACF
-
Reserved
-
-
Reserved for TAD settings
1166..33..1166..  R
Reesseerrvveedd aaddddrreessss
P
Phhoonneebbooookk
A
Addddrreessss
D
Deeffaauulltt
N
Naam
mee
C
Coouunnttrryy
S
Seettttiinngg
T
Tyyppee
D
Deessccrriippttiioonn
0AD0-D27
-
Reserved
-
D
Reserved for phonebook
U
Unnuusseedd
A
Addddrreessss
D
Deeffaauulltt
N
Naam
mee
C
Coouunnttrryy
S
Seettttiinngg
T
Tyyppee
D
Deessccrriippttiioonn
0D28-DEF
-
Unused
-
.
-
1166..33..1177..  P
PS
STTN
N LLiinnee
A
Addddrreessss
D
Deeffaauulltt
N
Naam
mee
C
Coouunnttrryy
S
Seettttiinngg
T
Tyyppee
D
Deessccrriippttiioonn
0F00
03
UserCfg-1.Mode
01
D
User configuration (MMI) - mode settings 1.
Bit
0 : "R" mode, 0=earth break, 1=loop break
2..1: Dial mode, 00:pulse, 01:DTMF
3..7: Reserved
0F01
0D
UserCfg-2.Mode
0C
D
User configuration (MMI) - mode settings 2.
Bit
0..1: short "R" key time selection
00= short, 01=long, 10=extra-long
2..3: long "R" key time selection
00= short, 01=long, 10=extra-long,
11=undef (uses same time as specified for short R key)
4..7: Reserved
Defaults to 0000 1101
0F02
10
UserCfg.RPauseTime
-
D
User configuration (MMI) - "R"-pause. If disabled,
normal dial pause (DialPauseTime) is used.
Bit 7..0 : "R" pause time, zero value allowed
Unit : 50 ms, defaults to 800 ms.
0F03
03
UserCfg.DialPauseTime
-
D
User configuration (MMI) - dial pause.
Bit 3-0 : dial pause in 1 sec units , zero not allowed.
Bit 7-4 : unused
Defaults to 3 seconds
0F04
0F
Cfg-1
2E
D
PSTN line configuration 1 (factory settings)
Bit
0: EarthBreakEnable , Earth break 1=enable 0=disable
1:LoopBreakEnable, Loop break 1=enable,0=disable
2:PulseDialEnable, Pulse dial 1=enable 0=disable
3:RPauseEnable, usage of "R" pause 1=enable,
0=disable
4:PulseType,0=normalpuls-type
1=(’0’=1 pils,..’9’=10 puls’s).
5: InterDigitLowImp. controls interdigit impedance.
0: normal impedance during interdigit pause
1: keep low-impedance during interdigit pause
6: LowImpLineSeizure. Special low-imp line seizure
(Australian) , 1=enable , 0=disable
7: TwoLines. line config 0=one line, 1=two linesDefaults
to 0000 0111B.
54
KX-TCD650RUC / KX-TCD650RUF
A
Addddrreessss
D
Deeffaauulltt
N
Naam
mee
C
Coouunnttrryy
S
Seettttiinngg
T
Tyyppee
D
Deessccrriippttiioonn
0F05
15
Cfg-2
14
PSTN line configuration 2 (factory settings)
Bit
0: Meter-pulse, 1=enable, 0=disable
1: DialToneMode, dial tone detection 1=enable
0=disable
2: BusyToneMode. busy tone detection 1=enable
0=disable
3: CurrentLimiterMode, 1=enable, 0=disable
4: RingToneMode. Ring tone detection 1=enable
0=disable
5: HookRelayEnable, 1=enable, 0=disable (if same port
is used for earth-control EarthBreakEnable and
HookRelayEnable cannot both be set to 1).
6..7: not used
Defaults to 0001 0101B.
0F06
28
MakeTime
-
D
Pulse make time.
Unit : 1 ms. defaults to 40 ms.
0F07
3C
BreakTime
-
D
Pulse break time
Unit : 1 ms, defaults to 60 ms.
0F08
64
DtmfTime
-
D
DTMF tone pulse time.
Unit : 1 ms, defaults to 100 ms.
0F09
0A
InterDigitDtmfTime
-
D
Inter-digit time in DTMF mode.
Unit : 10 ms , defaults to 100ms.
0F0A
4A
InterDigitPulseTime
-
D
Inter-digit time in Pulse mode.
Unit : 10 ms, defaults to 740 ms.
0F0B
08
CalibBreakTime[0]
0A
D
Calibrated loop-break time for short break
Unit : 10 ms, defaults to 80 ms.
0F0C
14
CalibBreakTime[1]
-
D
Calibrated loop-break time for long break
Unit : 10 ms, defaults to 200 ms.
0F0D
46
CalibBreakTime[2]
-
D
Calibrated loop-break time for extra-long break
Unit : 10 ms, defaults to 700 ms.
0F0E
28
CalibBreakTime[3]
-
D
Calibrated earth-break time for short break
Unit : 10 ms, defaults to 400 ms.
0F0F
82
CalibBreakTime[4]
-
D
Calibrated earth-break time for long break
Unit : 10 ms, defaults to 1300 ms.
0F10
82
CalibBreakTime[5]
-
D
Calibrated earth-break time for extra-long break
Unit : 10 ms, defaults to 1300 ms.
0F11
FF
LineSeizureEndTime
-
D
Line seizure end-time - time after hook-on. Meter-pulse
detection continues during this period of time. 00h or
FFh means 10 ms.
Unit : 10 ms, defaults to 10 ms.
0F12
64
RingTermToU100
-
D
Ring terminate time-out period. This is the max time
that must elapse between two ring-voltage bursts
before the new ring-voltage is registered as a new
incoming call.
Unit: 100 ms. defaults to approx 10 sec.
0F13
08
RingPatternToU100
-
D
Ring pattern timeout. Max. silence period during
distinctive ringing. As long as the silence period does
not exceed this period of time the ring is still considered
and counted as one single ring.
Unit : 100 ms. Defaults to 800 ms
0F14
FF
AgcUpdateTime
-
Line AGC update time. The period of time between
each line AGC update. If FFh, line-AGC is disabled. If
used recommended value is 64h (1 sec).
Unit : 10ms, min/max: 10/FF, Defaults to disabled.
0F15
0A
LineSeizureTime
-
Line seizure time. The period of time that the PSTN line
or the PSTN HW needs after the hook-switch is
activated in order to be ready. During this period audio
is muted. Only used during outgoing calls or if the
special-line seizure mode is enabled (Cfg:6).
Unit : 10 ms, min/max: 01/FF. Defaults to 100 ms.
0F16
66
InitDialPause
-
D
Init-dial-pause. Dial pause inserted after hook-off when
making an outgoing call.
Bit 0..3: init dial pause if PULSE dial-mode. If 0fH then
normal dial-pause is used.
Bit 4..7: init dial pause if DTMF dial-mode. if 0fH then
normal dial-pause is used.
Unit : 500 ms, min/max: 00/0F. Defaults to 3 sec and 3
sec.
0F17..1BB
FF..FF
Reserved[5]
-
D
55
KX-TCD650RUC / KX-TCD650RUF
1166..33..1188..  C
Clliipp ccoonnffiigguurraattiioonn
A
Addddrreessss
D
Deeffaauulltt
N
Naam
mee
C
Coouunnttrryy
S
Seettttiinngg
T
Tyyppee
D
Deessccrriippttiioonn
0F1C
0F
Detect
-
D
CLIP detect configuration
Bit
0: Onhook: 1=enable 0=disable
1: Offhook: 1=enable 0=disable
2: MsgWaiting: 1=enable 0=disable
3: LearnMode: 1=enable 0=disable
4: DtmfOnly: 1=enable 0=disable
5: FskOnly: 1=enable 0=disable
6: Unused6
7: Unused7
0F1D
05
Options
-
D
CLIP detect options
Bit
0: MuteOnCas: 1=enable 0=disable
1: AttenuateOnCas: 1=enable 0=disable
2: AckParallelPhone: 1=enable 0=disable
3: CasOnOnly: 1=enable 0=disable
4: Unused4
5: Unused5
6: Unused6
7: Unused7
0F1E
00
Ring configuration
-
D
Ring configuration
Bit
0: Rpas: 1=enable 0=disable
1: RpasAlert: 1=enable 0=disable
2: Rpas2LongAlert: 1=enable 0=disable
3: Power: 1=enable 0=disable
4: PowerAlert: 1=enable 0=disable
5: Silence: 1=enable 0=disable
6: Unused6
7: Unused7
0F1F
12
Rpas.RpasMinDuration
-
D
RPAS maximum duration.
Unit : 10 ms, defaults to 180 ms.
0F20
20
Rpas.RpasMaxDuration
-
D
RPAS maximum duration.
Unit : 10 ms, defaults to 320 ms.
0F21
00
Dtas.Configuration
-
D
DTAS Configuration
Bit
0:TimeValidate: 1=enable 0=disable
Enabled: DTAS pulse width is examined and
validated.
Disabled: DTAS start is used as FSK trigger.
1: Unused1
2: Unused2
3: Unused3
4: Unused4
5: Unused5
6: Unused6
7: Unused7
0F22
00
Dtas.SilenceTimeout
-
D
Silence period after RPAS.
Unit : 10 ms, defaults to 0 ms.
0F23
3C
Dtas.DtasMinDuration
-
D
DTAS minimum duration.
Unit : 1 ms, defaults to 60 ms.
0F24
82
Dtas.DtasMaxDuration
-
D
DTAS maximum duration.
Unit : 1 ms, defaults to 130 ms.
0F25
3C
Dtas.DataTimeout
-
D
DTAS to FSK data timeout
Unit : 10 ms, defaults to 600 ms.
0F26
01
Clip.ImpSet
-
D
Impedance set configuration
Bit
0: Polarity: 1=enable 0=disable
1: DtasStart: 1=enable 0=disable
2: DtasEnd: 1=enable 0=disable
3: Rpas: 1=enable 0=disable
4: RpasSilence: 1=enable 0=disable
5: PowerRing: 1=enable 0=disable
6: Unused6
7: Unused7
0F27
0F
Clip.ImpRemove
-
D
Impedance remove configuration
Bit
0: polarity: 1=enable 0=disable
1: Ringing: 1=enable 0=disable
2: ClipReceived: 1=enable 0=disable
3: Offhook: 1=enable 0=disable
4: Unused4: 1=enable 0=disable
5: Unused5: 1=enable 0=disable
6: Unused6
7: Unused7
56