8.4. Check Point (Charger Unit)
Items
Check
Point
Procedure
Check or
Replace Parts
(A)
Charging Check
-
 1. 
Connect Charge Contact 12
/2W resistor between charge+ and charge-.
 2. 
Measure and confirm voltage across the resistor is 2.85V ± 0.2V.
D11, R11, R12
Note:
After the measuring, sock up the solder of TP.
The connection of adjustment equipment is as shown in Adjustment Standard (Charger Unit) (P.33).
8.5. Adjustment Standard (Charger Unit)
When connecting the Simulator Equipments for checking, please refer to below.
8.5.1. Flow Solder Side View
TP3
TP2
TP1
A
D11
WHITE
BLUE
PbF
TP4
PQUP11305Z
DC POWER
6V
GND (TP2)
TP3
GND (TP2)
TP1
(A)
Digital
Volt Meter
12
/2W
R12
R11
R1
R2
Note:
(A) is referred to Check Point (Charger Unit) (P.33)
33
KX-TCD235RUS / KX-TCD235R UT / KX-TCA121RUS / KX-TCA121RUT
9 TROUBLESHOOTING BY SYMPTOM (HANDSET)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not.
Note:
(*1): A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2): Refer to Check Point (Handset) (P.34)
9.1. Check Point (Handset)
Please follow the items below when BBIC or EEPROM is replaced.
Note:
After the measuring, sock up the solder of TP.
*: PC Setting (P.38) is required beforehand.
The connections of adjustment equipments are as shown in Adjustment Standard (Handset) (P.39).
Items
Check
Point
Procedure
Check or
Replace Parts
(A)* 1.8V Supply Adjustment
VDD1
 1. 
Confirm that the voltage between test point VDD1 and GND is 1.8V ± 0.02V.
 2. 
Execute the command “bandgap”, then check the current value.
 3. 
Adjust the 1.8V voltage of VDD1 executing command “bandgap XX“(XX is the
value).
IC1, Q2, C40
(B)
DC/DC Supply
Confirmation
VDD3
 1. 
Confirm that the voltage between test point VDD3 and GND is 3.3V ± 0.3V
(Backlight is ON).
IC1, F1, C1,
C3, C57, R1,
Q1, D1, L1,57
(C)
2.5V Supply
Confirmation
VDD2
 1. 
Confirm that the voltage between test point VDD2 and GND is 2.5V ± 0.1V.
IC1, Q3, C4,
C5
(D)*
BBIC Confirmation
-
 1. 
BBIC Confirmation (Execute the command “getchk”).
 2. 
Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC1, X1,C7,
R19
(E)* EEP-ROM Confirmation
-
 1. 
EEP-ROM Confirmation (Execute the command “ChkTCA121XXrevYY”).
XX: country code
YY: revision number
 2. 
Confirm the returned checksum value.
Note:
“XX”, “YY”, and “checksum” vary depending on the country version. You can
find them in the batch file, PQZZ- mentioned in JIG and PC (P.38).
IC3, IC1, R39,
R40, R91,
R90, R96,
Q10, Q11,
C113
34
KX-TCD235RUS / KX-TCD235R UT / KX-TCA121RUS / KX-TCA121RUT
Items
Check
Point
Procedure
Check or
Replace Parts
(F) Charge Control Check &
Charge Current Monitor
Check
-
 1. 
Apply 6V between J3(+) and J4(-) with DC power supply and set current limit to
250mA.
 2. 
Confirm that the current limit LED of DC power supply is ON/OFF.
 3. 
Decrease current limit of DC power supply to 100mA.
 4. 
Confirm that the current limit LED of DC power supply is stable. (Current limiter
is ON.)
(If charge control cannot be confirmed by this procedure, please use battery to
handset power supply and try again.)
IC1, Q4, Q5,
Q9, D6, L4,
L5, C119,
C120, R5, R6,
R7, R72, F1
(G)* Charge Detection (OFF)
Check
-
 1. 
Stop supplying 6V to CHARGE(+) and CHARGE(-).
 2. 
Execute the command “Backloff” then “charge”.
 3. 
Confirm that the returned value is 0x00 (hex).
IC1, Q4, Q5,
Q9 D6, D7,
L4, L5, C119,
C120, R5, R6,
R7, R72, F1
(H)*
Battery Monitor Check
-
 1. 
Apply 2.25V between BATT and GND.
 2. 
Execute the command “readbatt”.
It assumes that the return value is XX.
a) 1E
XX
2C: No need to adjust
b) XX: 18 ~ 1D: Need to adjust
XX: 2D ~ 32: Need to adjust
Write AD value of 2.25V to EEPROM.
ex) read data: XX = 1D, write data: YY = 1D
read data: XX = 2D, write data: YY = 2D
EEPROM = 0X0004(Low Voltage) write “YY”, then
EEPROM = 0X0005(No Voltage) write “YY - 1D”
EEPROM = 0X000A(Low Voltage BL) write “YY - 06”
No Voltage writing data limit is ‘00’.
c) XX: 00 ~ 17: Reject
XX: 33 ~ FF: Reject
IC1, F1, C1
C3, C118
(I)
Battery Low
Confirmation
-
 1. 
Apply 2.40V between BATTERY(+) and BATTERY(-).
 2. 
Confirm that there is no flashing of Battery Icon.
 3. 
Apply 2.25V ± 0.08V between BATTERY(+) and BATTERY(-).
 4. 
Confirm that there is flashing of Battery Icon.
IC1, F1, C1
C3, C118
(J)* BBIC Clock Adjustment
CLK
 1. 
Apply 2.6V between BATTERY(+) and BATTERY(-) with DC power.
 2. 
Execute the command “conttx”.
 3. 
Input Command “rdeeprom 00 01 01”, then you can confirm the current value.
 4. 
Adjust the frequency of CLK executing the command “setfreq xx (where xx is
the value)” so that the reading of the frequency counter is 10.368000MHz ±
10Hz.
Note:
CLK is displayed only for a few seconds when executing the command “conttx”
after battery is inserted.
IC1, X1, CN6,
C7, R54, C62
(K)*
Transmitted Power
Confirmation
-
Remove the Antenna before starting step from 1 to 4.
 1. 
Configure the DECT tester (CMD60) as follows;
<Setting>
     • 
• 
• 
• 
Test mode: PP
     • 
• 
• 
• 
RFPI: 0102030405
     • 
• 
• 
• 
Traffic Carrier: 5
     • 
• 
• 
• 
Traffic Slot: 4
     • 
• 
• 
• 
Mode: Loopback
     • 
• 
• 
• 
RF LEVEL = -70dBm
 2. 
Execute the command “regcmd60 01 02 03 04 05".
 3. 
Initiate connection from DECT tester.
 4. 
Confirm that the NTP value at A201 is 20dBm ~ 25dBm.
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
35
KX-TCD235RUS / KX-TCD235R UT / KX-TCA121RUS / KX-TCA121RUT
Items
Check
Point
Procedure
Check or
Replace Parts
(L)*
Modulation Check and
Adjustment
-
Follow steps 1 to 3 of (K).
4.Confirm that the B-Field Modulation is -350 ~ -400/+320 ~ +370kHz/div using
data type Fig 31.
5.Adjust the B-Field Modulation if required. (Execute the command “Readmod”
and “wrtmod xx”, where xx is the value.)
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(M)
Frequency Offset
Confirmation
-
Follow steps 1 to 3 of (K).
4.Confirm that the frequency Offset is < ± 45kHz.
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(N)
Frequency Drift
Confirmation
-
Follow steps 1 to 3 of (K).
4.Confirm that the frequency Drift is < ± 30kHz/ms.
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(O)
Sensitivity Receiver
Confirmation
-
Follow steps 1 to 3 of (K).
4.Set DECT tester power to -88dBm.
5.Confirm that the BER is < 1000ppm.
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(P)
Timing Confirmation
-
Follow steps 1 to 3 of (K).
4.Confirm that the Timing accuracy is < ± 2.0ppm.
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(Q)*
RSSI Level
Confirmation
-
Follow steps 1 to 3 of (K).
4.Set DECT tester power to -81dBm.
5.Execute the command “readrssi“.
6.Confirm that the returned value is 0×1C ± 8 (hex).
7.Set DECT tester power to -63dBm.
8.Execute the command “readrssi“.
9.Confirm that the returned value is 0×25 ± 8 (hex).
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(R)
Power RAMP
Confirmation
-
Follow steps 1 to 3 of (K).
4.Confirm that Power RAMP is matching.
IC1, R54, C62,
C123, C60,
C63, C45,
C44, C47,
C46, C49,
C48, C50,
C53, C51,
R59, C54,
C55, CN6
(S)
Audio Check and
Confirmation
-
 1. 
Link to BASE which is connected to Line Simulator.
 2. 
Set line voltage to 48V and line current to 40mA.
 3. 
Input -45dBm/1KHz to MIC and measure Line output level.
 4. 
Confirm that the level is -9.5dBm ± 2dBm and that the distortion level is < 5%
at TEL Line (600
Load).
 5. 
Input -20dBm/1KHz to Line I/F and measure Receiving level at REV1 and
REV2.
 6. 
Confirm that the level is -21.0dBm ± 2dBm and that the distortion level is < 5%
at Receiver. (vol = 2)
IC1, C37, C68,
C91, R25,
R26, C20,
C12, C87,
C109, R85,
C103, C10,
C17, R86,
R29, R37,
R38, D4, D5,
C69, C70, C95
36
KX-TCD235RUS / KX-TCD235R UT / KX-TCA121RUS / KX-TCA121RUT
Page of 99
Display