6.8.2.2. Base Unit - jig (BS JIG) for
Handset
The base unit jig uses two modes: NORMAL POWER mode
and TEST POWER mode. These modes alternate when the
base unit LOCATOR button is pressed:
(1) NORMAL POWER mode, TEST SUPER LOW (red) is OFF.
This test simulates the handset is at normal/close distance.
The base unit is in NORMAL POWER mode right after the AC
adapter has been inserted.
(2) TEST SUPER LOW (POWER) mode, TEST SUPER LOW
LED (red) is ON. This test simulates the handset is at very large
distance from the base unit and the TX signal from base to
handset is very small.
Procedure:
First,
place
handset
under
test
to
charge
(exchange security code), then remove handset from base
after you hear a beep; press LOCATOR on base unit (red LED
lights). Press TALK button on handset and if it links with the
base, then this handset sensitivity is OK.
* BS JIG becomes [NORMAL POWER] mode immediately after
the power supply turning on.
NOTES:
1) If when setting the base to TEST SUPER LOW mode, if
handset beeps 3 times and the LCD shows "No link to base.
Place on cradle and try again", press 2, 5, 8, 0 simultaneously
and then disconnect battery. Re-install battery, place unit on
cradle to get security codes and tries again.
2) Only KX-TC1851B with marks BS JIG can be used for
troubleshooting. Regular KX-TC1851B production samples
does not have the software needed for troubleshooting.
3) You can differentiate the jig from a regular unit because the
jig has silver bottom cabinet (base) and back cabinet (handset).
21
KX-TC1811B
6.8.3. RF Check Flowchart
(*) Details of confirmation items are following in “6.8.4. Check Table for RF Block”.
22
KX-TC1811B
(*1)BS;Base unit, HS;Handset unit, HS JIG;Handset-jig, BS
JIG;Base unit-jig
(*2)Marconi setting
TX Freq.; 906.00MHz mode; WB
Spectrum analyzer setting
Freq. 906.00MHz Span 10MHz
RBW 1MHz or above VBW same as RBW
(*3)See “7 TEST MODE AND ADJUSTMENT
(*4)Do not adjust X101 when probe is directly attached to
X101. Test probe should be attached to antenna, then
adjust.
(*5)See 6.8.5. RF-DSP interface signal wave form.
6.8.4. Check Table for RF Block
No
Item
BS(Base uinit) (*1)
HS(Handset) (*1)
1a. Link confirmation
[NORMAL
POWER]
Procedure
 1. 
Put “HS JIG” on BS.
 2. 
Set MODE to [NORMAL POWER] position of
“HS JIG“.
 3. 
Press [TALK] key of “HS JIG” to establish link
.
 1. 
Put HS on “BS JIG”.
 2. 
Set MODE to [NORMAL POWER] position of
“BS JIG“.
 3. 
Press [TALK] key of “HS” to establish link.
1b. Link confirmation
[TEST POWER]
Procedure
 1. 
Change MODE to [TEST POWER] position of
“HS JIG”.
 2. 
Press [TALK] key of “HS JIG” to establish link
about 30cm away from “BS”.
 1. 
Change MODE to [TEST POWER] position of
“BS JIG”.
 2. 
Press [TALK] key of “HS“ to establish link
about 30cm away from “BS JIG”.
2
IC101 working
confirmation
Procedure
 1. 
Set Test-mode [Continuos Send Low
Power].(*3)
 2. 
Confirm X101 oscillate(24MHz). (*4)
 1. 
Set Test-mode [Continuos Send Low
Power].(*3)
 2. 
Confirm X101 oscillate(24MHz) (*4).
Check point
 1. 
Check X101 oscillator.
 2. 
Check DSP interface(IC101
←→
IC501/BS)
(*5).
 1. 
Check X101 oscillator.
 2. 
Check DSP interface(IC101
←→
IC201/HS)
(*5).
3
TX frequency
Adjustment
Procedure
 1. 
Set Test-model [Continuos Send Low
Power].(*3)
 2. 
Confirm TX-carrier frequency (1CH =
906MHz).
 1. 
Set Test-mode [Continuos Send Low
Power].(*3)
 2. 
Confirm TX-carrier frequency (1CH =
906MHz).
Check point
 1. 
Adjust frequency by VC101.(*3)
 2. 
Check X101 oscillator Circuit.
 1. 
Adjust frequency by VC101.(*3)
 2. 
Check X101 oscillator Circuit.
4
TX Power
confirmation
Procedure
 1. 
Put RF wire to ANT and ANT_GND(See 7.4.
Base Unit Reference Drawing
).
Connect this wire Marconi or Spectrum
Analyzer.
 2. 
Set Test-mode [Continuos Send Low
Power].(*3)
 3. 
Confirm TX power level within -3-±5dBm (*2)
(0.158~1.58mW)
 4. 
Set Test-mode [Continuos Send High
Power].(*3)
 5. 
Confirm TX power level within +17±4dBm
(20~126mW)
 1. 
Put RF wire to ANT and ANT_GND(See 7.5.
Handset Reference Drawing
).
 2. 
Set Test-mode [Continuos Send Low
Power].(*3)
 3. 
Confirm TX power level within -4±5dBm (*2)
(0.126~1.26mW)
 4. 
Set Test-mode [Continuos Send High
Power].(*3)
 5. 
Confirm TX power level within +16±4dBm
(16~100mW)
Check point
 1. 
Check F102 and T101 soldering.
 2. 
Check L102~107, C101~102 and C137
soldering.
 3. 
Check Antenna in BS.
 1. 
Check F102 and T101 soldering.
 2. 
Check L102~107, C101~102 and C137
soldering.
 3. 
Check Antenna in HS.
5
Receiver
confirmation
Procedure
 1. 
Put “HS JIG” on BS.
 2. 
Set MODE to [NORMAL POWER] position of
“HS JIG”.
 3. 
Press [TALK] key of “HS JIG“ to establish link
.
 4. 
Change MODE to [TEST POWER] position of
“HS JIG“.
 5. 
Press [TALK] key of “HS JIG” to establish link
about 30cm away from “BS”.
 1. 
Put HS on “BS JIG”.
 2. 
Set MODE to [NORMAL POWER] position of
“BS JIG”.
 3. 
Press [TALK] key of “HS” to establish link.
 4. 
Change MODE to [TEST POWER] position of
“BS JIG”.
 5. 
Press [TALK] key of “HS” to establish link
about 30cm away from “BS JIG“.
Check point
 1. 
Check F102 and T101 soldering.
 2. 
Check L102~107, C101~102 and C137
soldering.
 3. 
Check Antenna in BS.
 1. 
Check F102 and T101 soldering.
 2. 
Check L102~107, C101~102 and C137
soldering.
 3. 
Check Antenna in HS.
23
KX-TC1811B
6.8.5. RF-DSP interface signal wave form
24
KX-TC1811B
Page of 77