DOWNLOAD Panasonic KX-PRL260RUB / KX-PRLA20RUB Service Manual ↓ Size: 6.3 MB | Pages: 87 in PDF or view online for FREE

Model
KX-PRL260RUB KX-PRLA20RUB
Pages
87
Size
6.3 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / LINK-TO-CELL DOCKING STATION FOR IPHONE
File
kx-prl260rub-kx-prla20rub.pdf
Date

Panasonic KX-PRL260RUB / KX-PRLA20RUB Service Manual ▷ View online

29
KX-PRL260RUB/KX-PRLA20RUB
8.3.
How to Clear User Setting
Units are reset to the Factory settings by this operation (Erase recorded Voice messages, stored Phone numbers, Caller list and
etc.)
Note:
• Some menus are not reset. Refer to Operating Instructions (P.22).
• The reset menus differ depending on the following operations.
• This operation should not be performed for a usual repair.
8.3.1.
Resetting both base unit and handset
Both the base unit and the registered handset which you did the following steps 
 to 
 are reset. Other registered handsets
will not be reset.
Note:
(*1) Refer to Registering a Handset to a Base Unit in the Operating Instructions.
8.3.2.
Resetting only handset
The only handset is reset by doing the following steps 
 to 
.
Note: (*2)
• The handset registration to the base unit is cancelled.
• If the handset needs to be registered to the base unit, refer to Registering a Handset to a Base Unit in the Operating
Instructions.
• If users do not bring the base unit with them, the registration procedure has to be done by users themselves.
1
 Connect the AC adaptor to the base unit and install the charged batteries into the handset.
2
 Confirm the handset is registered to the base unit (     lights). 
    If the handset is not registered to the base unit (     lights), register it. (*1)
3
 Lift the handset and press 
{ih} to put the handset in standby mode.
4
 Press     ,     ,      and      key of the handset simultaneously until a confirmation tone is heard.
5
 Disconnect the AC adaptor, then remove the battery.
1
5
9
Handset
Base unit
w
1
 Install the charged batteries into the handset.
2
 Lift the handset and press {ih} to put the handset in standby mode.
4
 Remove the battery.
3
 Press     ,     ,      and      key of the handset simultaneously until a confirmation tone is heard. (*2)
3
5
7
#
Handset
30
KX-PRL260RUB/KX-PRLA20RUB
9 Troubleshooting Guide
9.1.
Troubleshooting Flowchart
Cross Reference:
Check Power (P.31)
Check Battery Charge (P.32)
Check Link (P.32)
Check the RF part (P.34)
Check Handset Transmission (P.37)
Check Handset Reception (P.37)
Check Caller ID (P.37)
Check BT Communication (P.39)
Note:
(*1) When a user claims that the unit disconnects a call right
after the greeting message and no incoming messages can
be recorded, this symptom can not reappear with TEL
simulator in the service center. In this case, try to change
the Auto disconnect activation time and Vox level. 
Power ON Base Unit
OK
FLOW CHART
Check Power
OK
Playback Pre-Message
Check Playback
Record
OK
Check Record
Range
Check the RF part
Handset Voice Transmission
Check Handset Transmission
Handset Voice Reception
OK
OK
OK
OK
Check Handset Reception
Caller ID function
Check Caller ID
Caller ID Error
No voice
No voice
Bluetooth Function
Check BT Communication
NG
Not charged
No playback
Not recording (*1)
Not working
NG
No link
OK
Link
Battery Charge
OK
Check Battery Charge
Check Link
31
KX-PRL260RUB/KX-PRLA20RUB
9.1.1.
Check Power
9.1.1.1.
Base Unit
Cross Reference:
Power Supply Circuit/Reset Circuit (P.12)
Note: 
BBIC is IC501.
(*1) Refer to Specifications (P.7) for part number and
supply voltage of AC adaptor.
(*2) Refer to Circuit Board (Base Unit_Main) (P.75).
9.1.1.2.
Handset
Cross Reference:
Power Supply Circuit/Reset Circuit (P.18)
Note: 
(*1) Refer to Circuit Board (Handset_Main) (P.79)
Is the AC Adaptor inserted into AC outlet? (*1)
Is output voltage of AC adaptor 5.5 V?
YES
Check
AC Adaptor.
Check VDD1(1.8 V) :Test point (VDD1)
(*2)
OK
Check Power Supply Circuit.
NO
NO
NO
NO
RSTN: Reset = "High"?(*2)
YES
Check Reset Circuit.
Check Xtal CLK=10.368 MHz?(*2)
YES
Check X501.
Check BBIC.
Check Power Supply Circuit/Reset Circuit.
Check X1, C52, C53.
Is the voltage of TP 1.8 V about 1.8 V?(*1)
Is the voltage of TP-VBAT 2.3 V more?(*1)
Check the battery and around BATT+ and 
BATT- are not shorted.
Is the battery inserted to BATT+ and BATT-?
Does BBIC (IC1: 49) oscillate at 10.368 MHz?(*1)
YES
YES
NO
NO
YES
Check BBIC (IC1).
YES
NO
32
KX-PRL260RUB/KX-PRLA20RUB
9.1.2.
Check Battery Charge
9.1.2.1.
Base Unit
Cross Reference:
Charge Circuit (P.13)
9.1.2.2.
Handset
Cross Reference:
Check Power (P.31)
Charge Circuit (P.19)
9.1.3.
Check Link
9.1.3.1.
Base Unit
Cross Reference:
Power Supply Circuit/Reset Circuit (P.12)
Check the RF part (P.34)
Note:
(*1) Refer to Things to Do after Replacing IC or X'tal (P.49)(P.55) for Base Unit.
(*2) Refer to Circuit Board (Base Unit_Main) (P.75)
Check Charge Circuit of Base Unit.
Check Handset.
Plug in the AC Power source.
Charge Handset on Base Unit.
Is the voltage of two charge contacts about
3 V or more?
OK
NO
Check Charge Contacts at 
Base Unit from mechanical point of view.
YES
Is BBIC (IC1: 34) high at charge state?
Check Charge Circuit.
Check Power of Handset.
Is Check Power OK?
NO
NO
YES
Check around Power Supply Circuit.
Does Base Unit connect to the properly working
Handset?
Check around X501 and RF module and adjust
clock frequency.(*1)
NO
NO
NO
NO
YES
YES
Is the voltage of VDD2 about 3.0 V?(*2)
Check the RF part
Does the RF clock (CLK) oscillate at 10.368 MHz in
Base Unit Test Mode?(*2)
YES
Is the voltage of VDD1 about 1.8 V?(*2)
YES
Base Unit is OK. Check Handset.
Page of 87
Display

Click on the first or last page to see other KX-PRL260RUB / KX-PRLA20RUB service manuals if exist.