25
KX-PRL260RUB/KX-PRLA20RUB
Frequently Used Items (Base Unit)
ex.)
Note:
(*1) When you enter the address or New Data, please refer to the table below.
(*2)
Items
Address
Default Data
New Data
Remarks
Frequency
00 07 / 00 08
70/02
-
-
Use  these  items  in  a  READ-ONLY mode to
confirm the contents. Careless rewriting may
cause serious damage to the computer system.
ID
00 02 ~ 00 06
Given value
-
-
SMS (FSK) receiving
sensitivity
0A 4B/0A 4A
00/51
00/1C
(3 dB up)
00/14              
(6 dB up)
When hex changes from “00/28” to “00/1C”or
“00/14”, gain increases by 6 dB or 12 dB.
SMS (FSK) sending level
0A DC/0A DB
00/40
19/20 (6 dB 
up)
32/40 (12 dB 
up)
When hex changes from “00 0B” to “00 16”or
“00 2C”, gain increases by 6 dB or 12 dB.
Bell length
03 B0
32 (5 sec) (*2)
1E (3 sec)
14 (2 sec)
This is time until bell stops ringing.
(Unit: 100 msec)
PULSE Dial speed
(10PPs->20PPs)
03 80
28 (40msec) 
(*2)
14 (20 msec)
-
This is pulse make time. (Unit:1msec)
03 81
3C(60 msec) 
(*2)
 1F (30 msec)
-
This is pulse break time. (Unit:1msec)
03 9F
57 (870 msec) 
(*2)
2C (440 msec)
-
This is inter-digit time in pulse mode. (Unit:10
msec)
Desired Number (hex)
Input Keys
Desired Number (hex)
Input Keys
0
0
A
[Flash] + 0
1
1
B
[Flash] + 1
.
.
C
[Flash] + 2
.
.
D
[Flash] + 3
.
.
E
[Flash] + 4
9
9
F
[Flash] + 5
Bell length
32 (hex) = 50 (dec) 
→ 100 × 100 msec = 5000 msec (5 sec)
PULSE Dial speed 
(10PPS -> 20PPS)
28 (hex) = 40 (dec) 
→ 40 × 1 msec = 40 msec  
3C (hex) = 60 (dec) 
→ 60 × 1 msec = 60 msec
57 (hex) = 87 (dec) 
→ 87 × 10 msec = 870 msec
26
KX-PRL260RUB/KX-PRLA20RUB
8.1.2.
Handset
Important:
     
Make sure the address on LCD is correct when entering new data. Otherwise, you may ruin the unit.
H/S LCD
H/S key operation
BACK
BACK
1).   Press 
{
      
}
.
2).   Select "Initial Setting" using      or     
       then press  
{
OK
}
 or 
{>}
.
{^}  {V}
3).   Enter "7", "2", "6", "2", "7", "6", "6", "4".
       Note: 7262 7664 = PANA SONI
                (see letters printed on dial keys)
5).   Enter "
ە
", "
ە
", "
ە
", "
ە
" (Address). (*1)  
7).   Press 
{
OK
}
 , a long confirmation beep 
       will be heard. 
8).   Press         (off) to return to standby mode.
          After that, remove and reinsert the batteries. Press the Power button for 
         about 1 second if the power is not turned on. 
6).   Enter "
㸨", "㸨" (New Data). (*1)
4).   Select "Write EEP" using      or     
       then press 
{
OK
}
 or 
{>}
.
{^}  {V}
Default Data
New Data
Service Mode
 Read EEP
 
Write EEP
 
Get S/W Ver.
Set Addr.:
_ _ _ _   _ _
Set Addr.:
Set Addr.:
OK
OK
OK
C
C
Soft keys
Navigator key/
?
(Volume) key
Dial keypad
{R/ECO}
R: Recall/Flash
ECO: Eco mode shortcut key
{
} (Off/Power)
27
KX-PRL260RUB/KX-PRLA20RUB
Frequently Used Items (Handset)
ex.)
Note:
(*1) When you enter the address or New Data, please refer to the table below.
(*2) When adding “01” (hex) to default value, sending level increases by 0.25 dB.
ex.)
(*3) When reducing “01” (hex) from default value, receiving level increases by 0.25 dB.
ex.)
(*4) Use these items in a READ-ONLY mode to confirm the contents. Careless rewriting may cause serious damage to the
handset.
Items
Address
Default Data
New Data
Possible Adjusted
Value MAX (hex)
Possible Adjusted
Value MIN (hex)
Remarks
Sending level
05 A1
Adjusted value
Given value
FF
D0
(*2)
Receiving level
05 A2
Adjusted value 
Given value
FF
D0
(*3)
Battery Low
00 09
70
-
-
-
(*4)
Frequency
00 08/00 07
02/70
-
-
-
ID
00 02~00 06
Given value
-
-
-
Desired Number (hex.)
Input Keys
Desired Number (hex.)
Input Keys
0
0
A
[Flash] + 0
1
1
B
[Flash] + 1
.
.
C
[Flash] + 2
.
.
D
[Flash] + 3
.
.
E
[Flash] + 4
9
9
F
[Flash] + 5
Item
Default Data
New Data
80
84
7C
Sending level
-8 dBm
-7 dBm
-9 dBm
Item
Default Data
New Data
80
84
7C
Receiving level
-22.0 dBm
-23.0 dBm
-21.0 dBm
28
KX-PRL260RUB/KX-PRLA20RUB
8.2.
EEPROM LAYOUT (Handset)
8.2.1.
Scope
The purpose of this section is to describe the layout of the EEPROM (IC3) for the handset.
The EEPROM contains hardware, software, and user specific parameters. Some parameters are set during production of the
handset, some are set by the user when configuring the handset, and some during normal use of the phone.
8.2.2.
Introduction
The handset uses a 128k bit serial EEPROM (IC3) for storing volatile parameters. All parameters are set up before the handset
the factory. Some of these are vital for the operation of the hardware so a set of default parameters is programmed before the
actual hardware fine-tuning can be initiated. This document lists all default settings with a short description.
This document lists all default parameters with a short description.
8.2.3.
EEPROM contents
MMI Setting:
MMI1 Setting:
Initial Type
Description
F
The data initialized by only F command
0
The data initialized by F and 0 command
1
The data initialized by F, 0 and 1 command
2
The data initialized by F, 0, 1 and 2 command
3
The data initialized by all command (F, 0, 1, 2, 3)
Country Setting
Description
x
Default - no specific country setting, so revert to default value.
Address Initial
Type
Name
 Description
Default value
Country
Setting
04 7E
3
EEP_Language
Selected Language for LCD
GERMAN:0 ENGLISH:1 SPANISH:2 NORWEGIAN:3 
FRENCH:4 ITALIAN:5 DENISH:6 DUTCH:7      SWEDISH:8     
FINNISH:9
GREEK:10 TURKISH:11 HUNGARIAN:12 PORTUGUESE:13 
RUSSIAN:14
POLISH:15  SLOVAKIAN:16  CZECH:17  CROATIAN:18  
CATALAN:19
UKRINIAN:20 SPANISHMEX:21   SLOVENIAN:22  
ESTNIAN:23    LITHUANIAN:24
LATVIAN:25  ROMANIAN:26   BULGARIAN:27  
MACEDONIAN:29
ALBANIAN:30  PORTUGUESEMEX:31    ENGLISH(USA):32  
HEBREW:33
ARABIC:34 PERSIA:35    HANTAI:36    HANTAI(HK):37  
RUSSIAN(BX):38
BELARUS:39  KAZAKHSTAN:40    UZBEKISTAN:41   
TAJIKISTAN:42  
TURKMENISTAN:43  AZERBAIJAN:44   ARMENIA:45  
MOLDOV:46
CANADAENGLISH:48  USSPANISH:49  USFRENCH:50  
PORTUGUESE:51  ENGLISH(AZ):52
0x01
0x0E
Address Initial
Type
Name
 Description
Default value
Country
Setting
00 12
F
EEP_LcdContrast
LCD contrast
0x28