DOWNLOAD Panasonic PT-TX400 / PT-TX310 / PT-TW340 / PT-TX210 / PT-TW250 (serv.man2) Service Manual ↓ Size: 21.38 MB | Pages: 84 in PDF or view online for FREE

Model
PT-TX400 PT-TX310 PT-TW340 PT-TX210 PT-TW250 (serv.man2)
Pages
84
Size
21.38 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / LCD PROJECTOR
File
pt-tx400-pt-tx310-pt-tw340-pt-tx210-pt-tw250-sm2.pdf
Date

Panasonic PT-TX400 / PT-TX310 / PT-TW340 / PT-TX210 / PT-TW250 (serv.man2) Service Manual ▷ View online

SPL-14
PT-TX400/PT-TX310/PT-TW340/PT-TW250/PT-TX210
  Location No.  Service Code  Description 
Note
  Location No.  Service Code  Description 
Note
Parts List
PACKING MATERIALS
P01  TQFW364 
MODEL No. LABEL 
TX400E
TQFW365 
MODEL No. LABEL 
TX400A
TQFW366 
MODEL No. LABEL 
TX400K
TQFW367 
MODEL No. LABEL 
TX400D
TQFW369 
MODEL No. LABEL 
TX310E
TQFW370 
MODEL No. LABEL 
TX310A
TQFW371 
MODEL No. LABEL 
TX310K
TQFW372 
MODEL No. LABEL 
TX310D
TQFW353 
MODEL No. LABEL 
TW340U
TQFW354 
MODEL No. LABEL 
TW340E
TQFW355 
MODEL No. LABEL 
TW340A
TQFW356 
MODEL No. LABEL 
TW340K
TQFW357 
MODEL No. LABEL 
TW340D
TQFW359 
MODEL No. LABEL 
TW250U
TQFW360 
MODEL No. LABEL 
TW250E
TQFW361 
MODEL No. LABEL 
TW250A
TQFW362 
MODEL No. LABEL 
TW250D
TQFW374 
MODEL No. LABEL 
TX210A
TQFW375 
MODEL No. LABEL 
TX210D
P02
 
6103614717
 POLY BAG 480X540mm 
P03
 H3600669900 CUSHION I
RIGHT 
P04
 H3600668900 CUSHION  LEFT
P05
 H3600671901 CARTON PARTITION
P06
 H3600670902  CARTON CASE 
P07 H3600692902    OUTSIDE CARTON CASE of  
US / Taiwan / Central and South America (U)  
 
Label  
 W01  H4201647501  High temperature warning label
 W02  H4201652501  Lens direct vision warning label 
 W03  H4201649500  LAMP EXCHANGE LABEL
 W04  H4201645500  PANASONIC AC IN LABEL
 W05  H4201726500  Top model label                        TX400 
H4201727500  Top model label 
         TX310
H4201730500  Top model label  
         TW340
H4201731500  Top model label 
      TW250
H4201728500  Top model label 
         TX210
 Cables
B01  H2110304501    IRIS Connect Cable
B02  H2110297501    main to protection switch
B03  H2110310500   Power to Ballast Cable
B04   H2110237501    Ballast to Lamp Housing
B05   H2110298500   Speaker Connect Cable
                                                   TX400/TX310/TW340/TW250
B06  H2110296501    TEMP SENSOR CABLE
B07  H2110305501    Speaker Connect Cable           TX210
B08   H2110287503    AC to Power CABLE
B09   H2110290502   Cable,Ballast Connect
B10   H2110292501   Remote control Cable    (Front)
     B11  H2110294502   Power to Mainboard Cable
B12   H2110307500  Remote control Cable    (Rear)
Accessories 
 D01 H4100614500  Manual (CD) 
 D02 H4100615500  Simple Manual (Paper) 
 D03  H2930094500  REMOTE CONTROL
 D04  H2100040501  Cable,1.5M,VGA D-Sub
 D05  H2100144500  Power  line of USA 
 D06   H2100147500   Power line for EU and Korea 
 D07   H2100148500   Power line of UK 
 D08   H2100140500   Power line of India 
 D09  H3600494900  Manual the big packing bag
Mechanical Parts
Cabinet Parts
C01/C02 H3701296500 ASSY-CAB-TOP
C03   H3400911500   DEC_lens-ring
 C04 H3400912500   DEC-RC-INLAY   (Front)
C05  H3400949500  DEC-RC-INLAY  (Rear)
 C06   H3400893501   panel_AV(high-end)
              TX400/TX310/TW340/TW250
 C07  H3400904500   panel_AV(Low-end)                   TX210  
 C08   H3400915500  CAB_BTM
C09   H3701229500   Air filter cover 
C10   H3400908500   BUTTON_ADJ
  C11  H3400885500 ADJ_STAND_SHAFT
C12   H3100646500   ADJ_RUBBER_FOOT
C13   H3300133500   ADJ_AXIS
 C14 H3100646500 RUBBER_FOOT
C15   H3400892500   Button
 C16 H3400891500   DEC_LED 
  
Screw 
S01  H3200220501  SCREW M2x3.0
S02  H3200276500  SCREW T3.0x8
S03  H3200124500  SCREW  M2.5X6
S04  H3200148500  SCREW  M2.5X8
S05  H3200278500  SCREW  T3.0X8
Core Parts
M01   H3400894500   DUCT_LCD_TOP
M02   H3400895500   DUCT_LCD_BTM
M03   H3400896500   DUCT_LAMP_TOP
M04   H3400897500   DUCT_LAMP_BTM
M05   H3400898500   DUCT_PBS_BTM
M06   H3400888500   MTG_BALLAST_MP
 M07   H3400864501   HLD_LMP_HOUSE
M08  H3100640500   SPACER-SHEET-FILTER
M09   H3100641500   SPACER_SHEET_BALLAST_TOP
M10   H3100642500   SPACER_SHEET_POWER_BTM
M11   H3300772500  SHIELD_BTM
M12   H3100525500   SPACER-INLAY_LED
M13   H3300759500   SHIELD_COVER_POWER
M14   H3300761501   shield-panel(high-end)
             TX400/TX310/TW340/TW250
M15   H3300769500   shield-panel(Low-end)
TX210
M16   H3300757500   SHIELD-AC
M17   H3300760500   SHIELD_COVER_MCSWITCH
M18   H3300758500   HOLDER_SECURITY
M19   H3300764500   SHIELD_DUCT
M20   H3300626500   MOUNTING_NUT
M21   H3100651500   Form,Black
M22   H3100663500   SPACER_PANEL-Audio
M23   H3100664500   SPACER_PANEL-full
              TX400/TX310/TW340/TW250
M24   H3100665500   SPACER_PANEL-simple           TX210
 M25 H3100665500   SPACER_PANEL-simple  
 M26 H3300781500 HOLDER-IR
M27   H3100694500   SPACER_TOP_FOCUS-HOLE
M28  H3100660500   SPACER_BUTTON
M29   H3100724500   Al_FIOL-TOP
M30   H3100722500   AL FOIL TOP2
M31   H3100681500   SPACER-INLAY_KEY
M32   H3300803500   AL-FOIL-POWER
SPL-15
PT-TX400/PT-TX310/PT-TW340/PT-TW250/PT-TX210
Parts List
  Location No.  Service Code  Description 
Note
  Location No.  Service Code  Description 
Note
  M33  H3100673500   SPACER-BTM-HOLE-BK
  M34   H3100667500   AL_FOIL_DUCT
  M35   H3100688500   SPACER FOR
   
                                           TX400/TX310/TW340/TW250
  M36   H3100682500   SPACER FOR                        TX210
  M37   H3300360500   FOOT SPRING
 
 
Optical Parts
  L01   H1800174500   CONDENSER LENS(IN)
  L02   H0440029500   Integrator UNIT     TX400/TX310/TX210
   
H0440031500    Integrator UNIT               TW340/TW250
  L03   H0440030500   PBS UNIT
  L04   H1800157500   LENS,CONDENSER (OUT)
  L05  H0440023500  CONDENSER LENS  UNIT (B)
  L06  H0440024500  CONDENSER LENS  UNIT (G)
  L07  H0440025500  CONDENSER LENS  UNIT (R)
  L08   H1800163500   Relay Lens(OUT)
  L09   H1200057500   DICROIC MIRROR(B)
  L10   H1200058500   DICROIC MIRROR(G)
  L11   H1200016500   MIRROR(B)
  L12   H1200017500   MIRROR(R)
 
L13   TXZKG03VJKZA   PRISM ASSY UNIT TYPE-L  
   
TXZKG03VJKZB   PRISM ASSY UNIT TYPE-L  
   
   
    
 
   TX400
   
TXZKG03VJRZA  PRISM ASSY UNIT TYPE-L
   
TXZKG03VJRZB   PRISM ASSY UNIT TYPE-R 
  
  
 
  
TX310/TX210
   
TXZKG03VHAZA   PRISM ASSY UNIT TYPE-L  
   
TXZKG03VHAZB   PRISM ASSY UNIT TYPE-R
  
  
 
 
 
TW340/TW250
  L14   H1800036501   LENS,RELAY(IN)
  L15   H1400036501   LENS_PROJECT_F1.8
 L16   H3400860500   OPT_BASE_TOP
 L17   H3400828500   OPT_BASE_BTM_CAB
  Electric Parts
  
A01  H2940486902E Main BOARD PCBA         TX400/TX310
  
H2940486902F Main BOARD PCBA     TW340/TW250  
A02 
H2940504903H
 Main BOARD PCBA              TX210
 A03  H2910087500  Ballast
A04  H2940441901  Temp.B Sensor Board 
A05  H2940451900  IR Board (Front) 
A06  H2940451900  IR Board (Rear)
 A07  H2940490901  PCBA, FILTER 
A08  H2130401500  AC socket with Cables
A09  H2940532901  PCBA, POWER
A10  H2160058500  TEMP SWTICH with cable
 A11  H2840082500 Speaker 
                                                      TX400/TX310/TW340/TW250
 A12  H2840048500  Speaker                                    TX210
 A13  H2160021500  LAMP COVER  SWTICH with cable
 A14  H1300143500  IRIS UNIT            TX400/TX310/TX210
  
H1300171500  IRIS UNIT                      TW340/TW250
 F2003   H2190011500   Fuse
 FN3005  H2840059501    FAN
FN3004  H2840108500    FAN
 FN3003  H2840108500    FAN
 FN3001  H2840107501     FAN 
FN3002  H2840024501    FAN
DIA-1
Schematic Diagrams
 
PT-TX400/PT-TX310/PT-TW340/PT-TW250/PT-TX210
Schematic Diagrams
Model 
PT-TW340
   
PT-TW250
   
PT-TX400
   
PT-TX310
 
 
PT-TX210
 
 
Important Safety Instruction
Components indicated by a   mark have special significance to product safety. Please use the parts specified by 
the manufacturer for replacement. 
Low and high voltage caution
The power circuit board comprises a circuit unit using a separate power supply and isolated from the ground. 
The circuit is divided into high voltage and low voltage circuits. Please adopt the following precautions. 
The schematic diagram is the final version before production. It may be revised without another notice. 
Precautions
Do not touch the part on hot side or both parts on the hot and cold sides at the same time. 
Do not shorten the circuit between hot and cold sides. Otherwise, the fuse will disconnect and parts will be damaged. 
Do not connect instruments such as an oscilloscope on both hot and cold sides to prevent the fuse from being melt. 
The measured circuit instrument should be grounded. 
When the core is removed, remove the power cable from the socket. 
When you book the part, check the maintenance code of the part on the parts list. 
DIA-2
SCH
Schematic Diagrams
MAIN
AC
B08
B03
FN3001
FN3002
FN3003
FN3004
FN3005
B05/B07
Speaker
B04
B11
B02
B10
B06
B01
B09
FILTER
POWER
3
4
5
6
7
8
9
1
1
2
3
4
5
6
7
8
9
10
1
2
BALLAST
R
LCD
PANEL
R
LCD
PANEL
R
LCD
PANEL
IRIS
TEMP.
SENSOR A
IR (FRONT)
1
2
3
1
3
2
2
2
2
2
1
1
1
1
3
3
3
3
1
1
1
RXD
1 2
1
2
2
2
2
GND
3
3
S3.3V
4
Lamp_SW
TXD
5
3
1
2
3
1
2
3
1
2
3
4
5
1
2
3
4
5
1
2
3
4
1
2
3
4
1
2
3
1
2
3
6
6
1
2
1
40
1
40
1
40
1
40
1
40
1
40
J9001
J9002
J9003
Panel_R
Panel_G
Power_Out
Lamp_Out
Lamp_Cold
FAN_C
FN3001
FN3002
FN3003
FN3004
FN3005
P5030
P3003
P3001
1
5
GND
GND
GND
GND
S16V
S16V
NC
S16V
S16V
PFC_ON
PTH
120
15.5V
380V
GND
LAMP
PHG231A11PXG
GND
GND
GND
GND
S16V
S16V
S-5V
S16V
S16V
PFC_ON
FAN_A
FAN_B
P3004
P3006
P3002
K2006
K2004
K2003
AC
100~240V
K2008
AC Socket
AC IN~
100~240V
IRIS
6
7
8
9
10
6
7
8
9
10
FAN_C
P5030
 
 
 
 
 
B12
IR (REAR)
Caution
Components indicated by a mark   in this schematic diagram have 
the  special  significance  in  the  safety.  It  is  therefore,  particularly 
recommended that the replacement of those parts must be made 
by exactly the same parts.Unauthorized substitutions may result in 
fire or accident.
This project is isolated from AC line by using the internal converter 
transformer. 
Please pay attention to the following notes in servicing. 
1.  Do not touch the part on the primary circuit or both the primary 
and secondary circuits at the same time. 
2.  Do not shorten the circuit between the primary and secondary 
sides. 
3.   The  grounding  lead  must  be  connected  to  the  ground  of  the 
same circuit when measuring the voltage and waveform. 
Page of 84