-93-
Electrical Adjustment
Grp / No. Item
Function
Range
Initial
Note
14 CSC_G_GP5
0 - 511
275
15 CSC_G_GP6
0 - 511
238
16 CSC_G_GP7
0 - 511
221
17 CSC_G_GP8
0 - 511
175
18 CSC_B_GP1
0 - 511
367
19 CSC_B_GP2
0 - 511
334
20 CSC_B_GP3
0 - 511
318
21 CSC_B_GP4
0 - 511
304
22 CSC_B_GP5
0 - 511
281
23 CSC_B_GP6
0 - 511
249
24 CSC_B_GP7
0 - 511
233
25 CSC_B_GP8
0 - 511
195
111
CXD3548_CSC_2Lamp_(1)(4) 
Color Shading Correction Threshold at Lamp 1, 4
0 CSC_XH
0 - 1
0
1 CSC_ON
0 - 1
1
2 CSC_R_GP1
0 - 511
375
3 CSC_R_GP2
0 - 511
339
4 CSC_R_GP3
0 - 511
317
5 CSC_R_GP4
0 - 511
303
6 CSC_R_GP5
0 - 511
291
7 CSC_R_GP6
0 - 511
266
8 CSC_R_GP7
0 - 511
223
9 CSC_R_GP8
0 - 511
142
10 CSC_G_GP1
0 - 511
402
11 CSC_G_GP2
0 - 511
355
12 CSC_G_GP3
0 - 511
328
13 CSC_G_GP4
0 - 511
313
14 CSC_G_GP5
0 - 511
300
15 CSC_G_GP6
0 - 511
277
16 CSC_G_GP7
0 - 511
241
17 CSC_G_GP8
0 - 511
176
18 CSC_B_GP1
0 - 511
412
19 CSC_B_GP2
0 - 511
367
20 CSC_B_GP3
0 - 511
335
21 CSC_B_GP4
0 - 511
319
22 CSC_B_GP5
0 - 511
306
23 CSC_B_GP6
0 - 511
284
24 CSC_B_GP7
0 - 511
251
25 CSC_B_GP8
0 - 511
196
112
CXD3550_CSC_2Lamp_(2)(3)
Color Shading Correction Threshold at Lamp 2, 3
0 CSC_XH
0 - 1
0
1 CSC_ON
0 - 1
1
2 CSC_R_GP1
0 - 511
354
3 CSC_R_GP2
0 - 511
326
4 CSC_R_GP3
0 - 511
310
5 CSC_R_GP4
0 - 511
298
6 CSC_R_GP5
0 - 511
286
7 CSC_R_GP6
0 - 511
263
8 CSC_R_GP7
0 - 511
220
9 CSC_R_GP8
0 - 511
135
10 CSC_G_GP1
0 - 511
359
11 CSC_G_GP2
0 - 511
335
12 CSC_G_GP3
0 - 511
317
13 CSC_G_GP4
0 - 511
305
14 CSC_G_GP5
0 - 511
295
15 CSC_G_GP6
0 - 511
273
16 CSC_G_GP7
0 - 511
238
17 CSC_G_GP8
0 - 511
175
18 CSC_B_GP1
0 - 511
352
19 CSC_B_GP2
0 - 511
336
20 CSC_B_GP3
0 - 511
319
21 CSC_B_GP4
0 - 511
308
22 CSC_B_GP5
0 - 511
298
23 CSC_B_GP6
0 - 511
279
24 CSC_B_GP7
0 - 511
249
25 CSC_B_GP8
0 - 511
196
140
Panel-LR
0 PANEL_LR
Panel Type Indication 0: Type-L, 1: Type-R
-
0
1 PANEL_CHG
Type Setting
Switch Type-R when the value is set to 20.
Switch Type-L when the value is set to 0.
0 - 20
10
-94-
Electrical Adjustment
Grp / No. Item
Function
Range
Initial
Note
200
Option
0 Logo Display Prohibition
0:Menu 1:Forced 
0 - 1
0
1 RS232C Baud rate
0:  19200bps 1:  9600bps
0 - 1
0
4 CABLE SW
Long Cable 0: Disable  1: Enable
0 - 1
0
6 Device Refresh Disable
0: Enable 1: Disable
0 - 1
0
8 PJ-NET HUNGUP CHK
0: Disable 1: Enable
0 - 1
0
51 Filter Warning Display
1:On 0:Off
0 - 1
1
53 Filter Counter Reset Times
Read only
0 - 255
0
54 Factory Default Executed Times
Read only
0 - 255
0
56 Menu Position (X)
X Offset
0 - 1024
0
57 Menu Position (Y)
Y Offset
0 - 1024
0
72 COMPONENT/RGB SW
0: Disable 1: Enable
0 - 1
1
140 OFFSET ADD MODE
Offset Tem Add Mode Display
0: No Addition, 1: Addtion
-
0
141 OFFSET ADD CHNG
Apply Offset Change when the data is set 10
0 - 10
0
142 OFFSET
Offset Temp 
-
10
143 TIMES OF OFFSET CHANGE
0 - 255
0
144 TIMES OF OFFSET RESET
0 - 255
0
201
Option (Signal) Not Used
0 FrameLock Option
Frame Lock Setting 
0: OFF for PC
1: OFF for AV
2: OFF
3: ON Depending on Input Frequency
4: ON Depending on Input Frequency
0 - 4
4
204
Simulation mode
0 Scaler Enable
0: Off, 1: On
0 - 1
0
205
Spread Spectrum
0 Enable
0: Off, 1: On
0 - 1
1
1 Spread Rate
Default 41
0 - 82
41
2 Spread Frequency
Default 0
0 - 2
0
220
Projector Error Log
0 Warning_Log_1
Latest Error log
0 - 32767
0
: :
:
:
:
49 Warning_Log_50
50th Error log
0 - 32767
0
50 Warning_Log Reset
Log is cleared when the value is set to 10.
0 ~ 10
0
235
Shutter
0 Power ON_OFF Motion
Shutter Warm - up Operation (0: Yes, 1: No)
0 - 1
Initial: 1 / Shipping: 0
1 CMP_TRM
Chattering Detecting Term
0 - 32767
7000
2 OUT_DLY_TRM
Output Term
0 - 32767
15000
3 CMP_CHK_CNT
Count of Information Sync
0 - 15
5
4 OPEN_DLY
Open Output Delay
0 - 63
0
5 CLOSE_DLY
Close Output Delay
0 - 63
0
6 Position Check Time
Position Check Time
1  -  255
30
7 Stop Mode
Shutter Operation in Stop Mode
0:Free, 1:Brake
0 - 1
0
8 Enable Close Cmd
Shutter Close Command
0:Disable, 1:Enable
0 - 1
1
10 Shutter Management Upper Time
180 - 999
480
240
Flow Calibration
0 Flow Calibration Exe
Flow Sensor Offset Calibration Start calibration when the value is 
set to 1.
0 - 1
0
1 Flow Calibration Error Log
Log of Calibration Error (Read only)
  255: Not Calibration  
  0: No Error  
 10: 1st Calibration Not Stable Airflow  
 11: 1st Calibration Out of Range  
 20: 2nd Not Stable Airflow  
 21: 2nd Out of Range 
 100: 10th Calibration Not Stable Airflow  
 101: 10th Calibration Out of Range
-
255
2 Clog Check Enable
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
0 - 1
Initial: 0 / Shipping: 1
3 Air Inlet Check Enable
Intake Vent Error Check (0: Disable, 1: Enable)
0 - 1
Initial: 0 / Shipping: 1
5 Clog Auto Cooling Enable
Cooling on Clog (0: Disable, 1: Enable)
0 - 1
1
6 Scroll Fail Auto Cooling Enable
Cooling on Scroll error (0: Disable, 1: Enable)
0 - 1
1
8 Filter Counter Remaining Enable
Filter Counter Remaining Function (0: Disable, 1: Enable)
0 - 1
1
13 Filter Stanbdard Limit
Filter life (x100 hour)
0 - 255
Normal filter: 50
Special filter: 10
14 Filter Max Limit
Filter Limit (x100 hour)
0 - 255
Normal filter: 60
Special filter: 15
-95-
Electrical Adjustment
Grp / No. Item
Function
Range
Initial
Note
241
Flow Ideal Data 
(Value will be set after calibration)
0 Flow Ideal Data 1
Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1
0 - 1023
330
1 Flow Ideal Data 2
Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2
0 - 1023
390
2 Flow Ideal Data 3
Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3
0 - 1023
420
3 Flow Ideal Data 4
Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4
0 - 1023
435
4 Flow Ideal Data 5
Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5
0 - 1023
440
5 Flow Ideal Data 6
Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6
0 - 1023
1023
6 Flow Ideal Data 7
Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7
0 - 1023
1023
7 Flow Ideal Data 8
Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8
0 - 1023
1023
242
Flow Calib. Fan Volt
 (Not Memorized)
0 Flow Calib Fan Volt 1
Flow Sensor Calibration Fan Volt No.1 [V x10]
0 - 255
32
1 Flow Calib Fan Volt 2
Flow Sensor Calibration Fan Volt No.2 [V x10]
0 - 255
46
2 Flow Calib Fan Volt 3
Flow Sensor Calibration Fan Volt No.3 [V x10]
0 - 255
61
3 Flow Calib Fan Volt 4
Flow Sensor Calibration Fan Volt No.4 [V x10]
0 - 255
84
4 Flow Calib Fan Volt 5
Flow Sensor Calibration Fan Volt No.5 [V x10]
0 - 255
100
5 Flow Calib Fan Volt 6
Flow Sensor Calibration Fan Volt No.6 [V x10]
0 - 255
255
6 Flow Calib Fan Volt 7
Flow Sensor Calibration Fan Volt No.7 [V x10]
0 - 255
255
7 Flow Calib Fan Volt 8
Flow Sensor Calibration Fan Volt No.8 [V x10]
0 - 255
255
243
Flow Calib Effective Difference
 (Not Memorized)
0 Flow Calib Effective Diff 1
Flow Sensor Calibration Range Diff No.1 [ADC]
0 - 1023
180
1 Flow Calib Effective Diff 2
Flow Sensor Calibration Range Diff No.2 [ADC]
0 - 1023
190
2 Flow Calib Effective Diff 3
Flow Sensor Calibration Range Diff No.3 [ADC]
0 - 1023
200
3 Flow Calib Effective Diff 4
Flow Sensor Calibration Range Diff No.4 [ADC]
0 - 1023
210
4 Flow Calib Effective Diff 5
Flow Sensor Calibration Range Diff No.5 [ADC]
0 - 1023
215
5 Flow Calib Effective Diff 6
Flow Sensor Calibration Range Diff No.6 [ADC]
0 - 1023
1023
6 Flow Calib Effective Diff 7
Flow Sensor Calibration Range Diff No.7 [ADC]
0 - 1023
1023
7 Flow Calib Effective Diff 8
Flow Sensor Calibration Range Diff No.8 [ADC]
0 - 1023
1023
244
Flow Clog Threshold 
(Not Memorized )
0 Flow Clog Threshold 1
Flow Sensor Clogged Threshold No.1[ADC]
0 - 1023
260
1 Flow Clog Threshold 2
Flow Sensor Clogged Threshold No.2[ADC]
0 - 1023
320
2 Flow Clog Threshold 3
Flow Sensor Clogged Threshold No.3[ADC]
0 - 1023
350
3 Flow Clog Threshold 4
Flow Sensor Clogged Threshold No.4[ADC]
0 - 1023
400
4 Flow Clog Threshold 5
Flow Sensor Clogged Threshold No.5[ADC]
0 - 1023
430
5 Flow Clog Threshold 6
Flow Sensor Clogged Threshold No.6[ADC]
0 - 1023
1023
6 Flow Clog Threshold 7
Flow Sensor Clogged Threshold No.7[ADC]
0 - 1023
1023
7 Flow Clog Threshold 8
Flow Sensor Clogged Threshold No.8[ADC]
0 - 1023
1023
10 Flow Inlet Err Threshold 1
Flow Sensor Intake Err Threshold No.1 [ADC]
0 - 1023
360
11 Flow Inlet Err Threshold 1
Flow Sensor Intake Err Threshold No.1 [ADC]
0 - 1023
420
12 Flow Inlet Err Threshold 1
Flow Sensor Intake Err Threshold No.1 [ADC]
0 - 1023
450
13 Flow Inlet Err Threshold 1
Flow Sensor Intake Err Threshold No.1 [ADC]
0 - 1023
500
14 Flow Inlet Err Threshold 1
Flow Sensor Intake Err Threshold No.1 [ADC]
0 - 1023
530
15 Flow Inlet Err Threshold 1
Flow Sensor Intake Err Threshold No.1 [ADC]
0 - 1023
1023
16 Flow Inlet Err Threshold 1
Flow Sensor Intake Err Threshold No.1 [ADC]
0 - 1023
1023
17 Flow Inlet Err Threshold 1
Flow Sensor Intake Err Threshold No.1 [ADC]
0 - 1023
1023
246
Flow Clog Monitor 
(Read only)
0 Real Flow Data
Real Flow Data [ADC] (Read only)
0 - 1023
-
1 Ideal Flow Data
Theory Flow Data (Read only)
0 - 1023
-
2 Flow Difference Data
Flow Difference Data [ADC] (Read only)
-1023 - 1023
-
3 Clog Detect Flow Difference Data Difference Data to judge the Filter Clogged [ADC] (Read only)
0 - 1023
-
4 Warn Detect Flow Difference Data Difference Data to judge the Filter Clogged Warning [ADC] (Read 
only)
0 - 1023
-
5 Press Add Data
Add Data by Air Pressure (Read only) 
0 - 1023
-
6 Filter Scroll Timer
Timer for Filter Scroll [hour] (Read only)
0 - 32767
-
7 Air Inlet Err Difference Data
Difference to judge the Intake Error
0 - 1023
-
249
Pressure Sensor
0 Pressure Monitor
Pressure Sensor Value [ADC] (Read only)
-
-
1 Pressure Monitor
Pressure Sensor Value with Compensate [ADC] (Read only)
-
-
2 Presss Offset
Offset Value
- 1023 - 1023
0
3 Press calib Effective Diff
Effective Range [ADC]
0 -123
1023
4 Press Sensor Calibration Log
0: Executed & Normal Range (Read ony)
10: Out of Range Minimum
20: Out of Range Maximum
99: Not execute Calibration
-
99
252
Fan Option
1 Safety Switch
Safety Application use
0 - 8
0
2 Fan Manual Switch
Fan Manual SW   (0: Auto  1: Manual)
0 - 1
0
-96-
Electrical Adjustment
Grp / No. Item
Function
Range
Initial
Note
3 Fan 1 Manual Voltage
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
0 - 255
50
4 Fan 2 Manual Voltage
0 - 255
50
5 Fan 3 Manual Voltage
0 - 255
50
6 Fan 4 Manual Voltage
0 - 255
50
7 Fan 5 Manual Voltage
0 - 255
50
8 Fan 6 Manual Voltage
0 - 255
50
9 Fan 7 Manual Voltage
0 - 255
50
10 Fan 8 Manual Voltage
0 - 255
50
11 Fan 9 Manual Voltage
0 - 255
50
253
Fan Temp Error Setting 
(Memorized)
Normal Ceiling
Top
Bottom
0 Temp A Warning 
Temp A (Room) to judge the Temp Error
30 - 100
47
47
47
47
1 Temp C-A Warnin
Temp C-A (Panel - Room) to judge the Temp Error
0 - 100
15
15
15
15
2 Temp C-A Warning Offset (Temp) Temp Error Offset Temp
0 - 100
13
3 Temp C-A Warning Offset (Time) Temp Error Offset Time
0 - 40
15
4 Temp A Warning (Smoke cut filter) For Smoke cut filter used
30 - 100
47
254
Fan Control Range Setting 
(Temp/Voltage)
Normal Ceiling
Top
Bottom
0 Normal  Fan Control Min Temp
Temp Sensor Control Start/End Temp at Normal
20 - 100
28
28
28
28
1 Normal  Fan Control Max Temp
20 - 100
43
43
43
43
2 Normal Fan 1 Min
Fan Voltage Set at Normal (Min/Max) (Duty)
0 - 255
50
50
53
53
3 Normal Fan 1 Max
0 - 255
85
85
88
88
4 Normal Fan 2 Min
0 - 255
37
37
37
37
5 Normal Fan 2 Max
0 - 255
100
100
100
100
6 Normal Fan 3 Min
0 - 255
41
41
41
41
7 Normal Fan 3 Max
0 - 255
100
100
100
100
8 Normal Fan 4 Min 
0 - 255
41
41
41
41
9 Normal Fan 4 Max 
0 - 255
100
100
100
100
10 Normal Fan 5 Min 
0 - 255
55
55
50
53
11 Normal Fan 5 Max
0 - 255
55
55
50
53
12 Normal Fan 6 Min 
0 - 255
55
55
50
53
13 Normal Fan 6 Max
0 - 255
55
55
50
53
14 Normal Fan 7 Min 
0 - 255
55
55
50
53
15 Normal Fan 7 Max
0 - 255
55
55
50
53
16 Normal Fan 8 Min 
0 - 255
55
55
50
53
17 Normal Fan 8 Max
0 - 255
55
55
50
53
18 Normal Fan 9 Min 
0 - 255
42
42
42
42
19 Normal Fan 9 Max
0 - 255
100
100
100
100
20 Normal Fan 10 Min 
0 - 255
30
30
30
30
21 Normal Fan 10 Max
0 - 255
100
100
100
100
22 Normal Fan 11 Min 
0 - 255
38
38
38
38
23 Normal Fan 11 Max
0 - 255
100
100
100
100
24 Normal Fan 12 Min 
0 - 255
36
36
36
36
25 Normal Fan 12 Max
0 - 255
100
100
100
100
26 Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp at Eco
20 - 100
28
28
28
28
27 Eco Fan Control Max Temp
20 - 100
43
43
43
43
28 Eco Fan 1 Min
0 - 255
35
35
38
38
29 Eco Fan 1 Max
0 - 255
70
70
73
73
30 Eco Fan 2 Min
Fan Voltage Set at Eco (Min/Max) Duty)
0 - 255
36
36
36
36
31 Eco Fan 2 Max
0 - 255
86
86
86
86
32 Eco Fan 3 Min
0 - 255
36
36
36
36
33 Eco Fan 3 Max
0 - 255
86
86
86
86
34 Eco Fan 4 Min 
0 - 255
36
36
36
36
35 Eco Fan 4 Max 
0 - 255
86
86
86
86
36 Eco Fan 5 Min 
0 - 255
35
35
35
38
37 Eco Fan 5 Max 
0 - 255
35
35
35
38
38 Eco Fan 6 Min 
0 - 255
35
35
35
38
39 Eco Fan 6 Max 
0 - 255
35
35
35
38
40 Eco Fan 7 Min 
0 - 255
35
35
35
38
41 Eco Fan 7 Max 
0 - 255
35
35
35
38
42 Eco Fan 8 Min 
0 - 255
35
35
35
38
43 Eco Fan 8 Max 
0 - 255
35
35
35
38
44 Eco Fan 9 Min 
0 - 255
32
32
3
32
45 Eco Fan 9 Max 
0 - 255
82
82
82
82
46 Eco Fan 10 Min 
0 - 255
28
28
28
28
47 Eco Fan 10 Max 
0 - 255
82
82
82
82
48 Eco Fan 11 Min 
0 - 255
30
30
30
30
49 Eco Fan 11 Max 
0 - 255
82
82
82
82
50 Eco Fan 12 Min 
0 - 255
30
30
30
30
51 Eco Fan 12 Max 
0 - 255
82
82
82
82
52 Silent Mode Offset Normal Fan 1 Min Fan Voltage Set at Silent Normal (Min/Max) (Duty)
0 - 255
0
53 Silent Mode Offset Normal Fan 1 Max  Subtract this value from normal value
0 - 255
0
54 Silent Mode Offset Normal Fan 2 Min
0 - 255
0
Page of 127