  2. 7. Removal of Rod (Assy)
1. Remove the Upper Case according to the section 2.2. "Removal of Upper Case". (In advance, remove the lamp cases.)
2. 1) Unscrew the 9 screws and remove the Lamp fan block.
    2) Unscrew the 2 screws and remove the Ballast bracket.
3. 1) Unscrew the 7 screws and remove the Lamp fan base.
    2) Unscrew the 2 screws and remove the RL-P.C.B bracket.
XYN3+F8FJ
XYN3+F8FJ
Lamp fan block
Ballast bracket
RL-P.C.B bracket
XYN3+F8FJ
DIS-15
4. Unscrew the 4 screws and remove the Rod cover.
* Please pull straight it up not
to injure a rod integrator.
XYN3+F8FJ
Rod cover
XYN3+F8FJ
Lamp fan bas
XYN4+J12FJ
DIS-15
5. Unscrew the 3 screws and remove the Rod (assy).
  2. 8. Removal of Iris unit (Assy)
1. Remove the Upper Case according to the section 2.2. "Removal of Upper Case".
2. Unscrew the 2 screws and remove the Color prism 1 Fan block.
* Please be careful so that a fingerprint and dust do not stick.
XYN4+F10FJ
Rod (assy)
Color prism 1
Fan block
DIS-16
3. Unscrew the 3 screws and release the Intake duct block.
XYN3+F8FJ
Color prism 1
Fan block
XYN4+J12FJ
Intake duct block
DIS-16
4. 1) Shifting the position of the Intake duct block, then unscrew the 1 screw and remove the Iris cover.
    2) Unscrew the 2 screws and remove the Iris unit.
  2. 9. Removal of Analysis mirror / Lens Mount (Assy)
1. Remove the Intake duct block and DMD block, according to the steps 1 through 7 in the section
XYN3+F8FJ
Iris cover
Intake duct block
XYN3+F8FJ
Iris unit
DIS-17
1. Remove the Intake duct block and DMD block, according to the steps 1 through 7 in the section 
    2.6 "Removal of DMD block/Liquid cooling unit".
2. Remove the Rod (assy) according to the section 2.7 "Removal of Rod (assy)".
3. Unscrew the 7 screws, release the Analysis block and Lanp-L/R fan block.
THEL114J
XYN4+J12FJ
Analysis block
Lamp-L fan block
Lamp-R fan block
DIS-17
4. Unscrew the 1 screw and remove the Luminance sensor block.
5. 1) Slightly lift the Analysis block(with lamp L/R fan) and slide back.
* Please note that bimetal cable are connected.
    2) Unscrew the 4 screw and remove the Analysis mirror block.
XYN3+F8FJ
Luminance sensor
block
XYN4+J12FJ
Analysis mirror
block
※: When installing, tighten
this screw at the end.
Tightening torque
100~150cN・m
DIS-18
6. Unscrew the 6 screw and remove the Lens mount.
Analysis block
(with lamp L/R fan)
XYN4+F14FJ
Lens mount (assy)
DIS-18