Panasonic PT-DZ21KU / PT-DZ21KE / PT-DS20KU / PT-DS20KE / PT-DW17KU / PT-DW17KE (serv.man2) Service Manual ▷ View online

2. OSD Menu Navigation
INF - 5
INF - 5
INF - 6
INF - 6
3. Service Mode
This projector has Service Mode in addition to standard on-screen menus (User Mode).
This mode enables some menu settings for the service operation.
  3. 1. Setting to Service Mode
1. Please push the main body or the menu (MENU) button of the wireless remote controller.
2. Choose a sub menu "service password" of the main menu "projector setup" and push the enter (ENTER) button.
3. Input the password "1565" by remote control and press the ENTER button.
4. Press the MENU button. "SERVICE MODE" (MAIN MENU) will be displayed.
  3. 2. Resetting to User Mode
1. Please push the main body or the menu (MENU) button of the wireless remote controller.
2. Choose a sub menu "service password" of the main menu "projector setup" and push the enter (ENTER) button.
3. Input the password "0000" by remote control and press the ENTER button.
4. Press the MENU button. "USER MODE" (MAIN MENU) will be displayed.
  3. 3. Functions in Service Mode
    3. 3. 1. EXTRA OPTION
EXTRA OPTION is added to bottom in the MAIN MENU.
[ Note ]
Function specification varies according to a version of the main microcomputer software.
1.
2.
3.
4.
5.
INF - 7
  1. LIGHT OUTPUT
Adjusts brightness with Dynamic Iris. It darkens as the value becomes small.
  2. MAX IRIS LEVEL
Adjustment the maximum diaphragm quantity of the Dynamic iris. Please do not usually change setting.
When changed an iris unit or a DMD block, please adjust it according to Clause 1 of SECTION 3 (Adjustments).
  3. DYNAMIC GAMMA MODE
Sets ON (Valid) / OFF (Invalid) of Dynamic gamma.
  4. 3DCMS
Sets ON (Valid) / OFF (Invalid) of 3D Color Management system.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
INF - 7
  5. SELF CHECK
Self-diagnosing information Displays.
 SELF CHEC
①-
 MAIN  : R1.00
②-
 SUB   : R1.00
③-
 NT    : R1.00 / 1.00
④-
 OK  AIR TEMP 123/456   OK DMD TEMP 123/456
⑤-
 OK  OUT TEMP 123/456   OK AIR FLOW 123/456/789
⑥-
 OK  LAMP1  12345H  3OM ON
⑦-
 OK  LAMP2  12345H  3OM ON
⑧-
 OK  LAMP3  12345H  3OM ON
⑨-
 OK  LAMP4  12345H  3OM ON
⑩-
 OK  FAN    1111 1111 1111 1111 1111 11
⑪-
 OK  PHOTO SENSOR Y 12345.6
⑫-
 OK  ANGLE SENSOR H -12.34/V +56.78
⑬-
 OK  IRIS
⑭-
 OK  SHUTTER 12345 [   0]
①-
Main microprocessor Software Version
②-
Sub microprocessor Software Version
③-
Network microprocessor Software Version (rootfs/kernel)
④-
Intake air temperature (Celsius/Fahrenheit)
DMD temperature (Celsius/Fahrenheit)
⑤-
Exhaust air temperature (Celsius/Fahrenheit)
Airflow sensor (Sensor value/AD conversion value
⑥-
LAMP1 condition (Cumulative usage time/ON-OFF)
/Correction value)
⑦-
LAMP2 condition (Cumulative usage time/ON-OFF)
⑧-
LAMP3 condition (Cumulative usage time/ON-OFF)
⑨-
LAMP4 condition (Cumulative usage time/ON-OFF)
When the item from 4 to 14 is abnormal last time and shuts it down,
the font of OK becomes red.
INF - 8
⑩-
Fan condition (1: normal /0:stop)
  OK FAN
⑪-
Brightness sensor condition
⑫-
Angle sensor condition (Horizontal angle / Vertical angle)
⑬-
Iris Condition
⑭-
Shutter condition (Opening and shutting number of times [Failed number of times])
  6. POWER OFF MESSAGE
Setting of the shutter function with standby operation
  - SHUTTER KEEP: When push the standby key with shutter ON, keep the shutter mode.
  - SHUTTER OPEN: When push the standby key with shutter ON, open the shutter and display 
   the "Power OFF confirmation message". (Default setting)
  7. ERROR OSD
When do not watch the error instructions LED of the lamp by a back projection,
the errors of the lamp can be displayed in the OSD.
  - ON: "Lamp error message" is displayed on OSD.
  - OFF: Does not display the "Lamp error message" in OSD.
  8. CONVERGENCE
When the ingredient of each R/G/B color deviation, revise it electrically.
Specifically, please refer to Clause 1 of SECTION 3 (adjustments).
E
xhaust 
1
E
xhaust 
2
E
xhaust 
3
E
xhaust 
4
Intake 
1
Intake 
2
Lamp 
1
Lamp 
2
Lamp 
3
Lamp 
4
Ba
lla
st 
1
Ba
lla
st 
2
Po
we
r
S
ignal
Lamp 
R
Lamp 
L
Co
lo
r p
rism
 1
Co
lo
r p
rism
 2
P
ump-R
ed
P
ump-Green
P
ump-B
lu
e
Co
lo
r p
rism
 3
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1
1
INF - 8
Page of 110
Display

Click on the first or last page to see other PT-DZ21KU / PT-DZ21KE / PT-DS20KU / PT-DS20KE / PT-DW17KU / PT-DW17KE (serv.man2) service manuals if exist.