Panasonic PT-DZ13KE / PT-DZ8700 Service Manual ▷ View online
After Adjustment
53
Hold the DMD plate by tightening 4 screws (2.0mm hex
For R convergence adjust
Mounting instruction of RECONVER UNIT
54
(1) Remove the top cover
(2) Remove the filter unit.
Mounting instruction of RECONVER UNIT
55
(3) Pull out 3 connectors, then
remove the DMD mounter cover
remove the DMD mounter cover
Mounting instruction of RECONVER UNIT
56
(4) Pull out the power line connector
from the FM‐PCB,
then attach the RECONVER_BASE.
from the FM‐PCB,
then attach the RECONVER_BASE.
(5) Insert the R‐FM‐PCB power line
connector.
connector.