KX-MB2110RUW/ KX-MB2130RUW/ KX-MB2170RUW/ KX-MB2117RUB/ KX-MB2137RUB/ KX-MB2177RUB
18.1.20. Actual Size of Screws and Washer------------ 392
18.1.21. Accessories and Packing Materials ----------- 394
18.2. Electrical Parts List------------------------------------- 396
18.2.1. Main Board (For MB2110) ----------------------- 396
18.2.2. Main Board (For MB2117) ----------------------- 399
18.2.3. Main Board (For MB2130)----------------------- 403
18.2.4. Main Board (For MB2137)----------------------- 408
18.2.5. Main Board (For MB2170)----------------------- 413
18.2.6. Main Board (For MB2177)----------------------- 418
18.2.7. Operation Board ----------------------------------- 423
18.2.8. Sensor Board --------------------------------------- 425
18.2.9. LCD Back Light Board---------------------------- 426
18.2.10. High Voltage Power Supply Board ------------ 426
18.2.11. Low Voltage Power Supply Board ------------- 426
19 Appendix
--------------------------------------------------------- 427
6
KX-MB2110RUW/ KX-MB2130RUW/ KX-MB2170RUW/ KX-MB2117RUB/ KX-MB2137RUB/ KX-MB2177RUB
1 Safety Precautions
1. Before servicing, unplug the AC power cord to prevent an electric shock.
2. When replacing parts, use only the manufacturer's recommended components.
3. Check the condition of the power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure to perform the following insulation resistance test to prevent
the customer from being exposed to shock hazards.
1.1.
For Service Technicians
• Repair service shall be provided in accordance with repair technology information such as service manual so as to pre-
vent fires, injury or electric shock, which can be caused by improper repair work.
1. When repair services are provided, neither the products nor their parts or members shall be remodeled.
2. If a lead wire assembly is supplied as a repair part, the lead wire assembly shall be replaced.
3. FASTON terminals shall be plugged straight in and unplugged straight out.
• ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help prevent recurring malfunctions.
1. Cover the plastic part's boxes with aluminum foil.
2. Ground the soldering irons.
3. Use a conductive mat on the worktable.
4. Do not touch the IC or LSI pins with bare fingers.
1.2.
AC Caution
For safety, before closing the lower cabinet, please make sure of the following precautions.
1. The earth lead is fixed with the screw.
2. The AC connector is connected properly.
7
KX-MB2110RUW/ KX-MB2130RUW/ KX-MB2170RUW/ KX-MB2117RUB/ KX-MB2137RUB/ KX-MB2177RUB
1.3.
Personal Safety Precautions
1.3.1.
Moving Sections of the Unit
Be careful not to let your hair, clothes, fingers, accessories, etc., become caught in any moving sections of the unit.
The moving sections of the unit are the rollers and a gear. There is a separation roller and a document feed roller which are rotated
by the document feed motor. A gear rotates the two rollers. Be careful not to touch them with your hands, especially when the unit
is operating.
1.3.2.
Live Electrical Sections
All the electrical sections of the unit supplied with AC power by the AC power cord are live.
Never disassemble the unit for service with the AC power supply plugged in.
CAUTION:
AC voltage is supplied to the primary side of the Low Voltage Power Supply Board (SMPS board). Therefore, always unplug the
AC power cord before disassembling for service.
Discharge the primary electrolytic capacitor before touching the SMPS board.
Discharge the primary electrolytic capacitor 
1.4.
Service Precautions
1.4.1.
Precautions to Prevent Damage from Static Electricity
Electrical charges accumulate on a person. For instance, clothes rubbing together can damage electric elements or change their
electrical characteristics. In order to prevent static electricity, touch a metallic part that is grounded to release the static electricity.
Never touch the electrical sections such as the Power Supply boards, etc.
8
KX-MB2110RUW/ KX-MB2130RUW/ KX-MB2170RUW/ KX-MB2117RUB/ KX-MB2137RUB/ KX-MB2177RUB
2 Warning
2.1.
About Lead Free Solder (PbF: Pb free)
Note:
In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that con-
tains lead.
We will use PbF solder when discussing the lead free solder used in our manufacturing process which is made from Tin, (Sn),
Silver, (Ag), and Copper, (Cu).
This model, and others like it, manufactured using lead free solder will have PbF stamped on the PCB. For service and repair
work we suggest using the same type of solder although, with some precautions, standard Pb solder can also be used.
Caution
• PbF solder has a melting point that is 50
 ~ 70 F, (30 ~ 40C) higher than Pb solder. Please use a soldering iron with tempera-
ture control and adjust it to 700
 ± 20 F, (370 ± 10C). In case of using high temperature soldering iron, please be careful not to
heat too long.
• PbF solder will tend to splash if it is heated much higher than its melting point, approximately 1100
F, (600C).
• If you must use Pb solder on a PCB manufactured using PbF solder, remove as much of the original PbF solder as possible and
be sure that any remaining is melted prior to applying the Pb solder.
• When applying PbF solder to double layered boards, please check the component side for excess which may flow onto the
opposite side (See figure, below).
2.1.1.
Suggested PbF Solder
There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper,
(Sn+Ag+Cu), you can also use Tin and Copper, (Sn+Cu), or Tin, Zinc, and Bismuth, (Sn+Zn+Bi). Please check the manufac-
turer’s specific instructions for the melting points of their products and any precautions for using their product with other 
materials. 
The following lead free (PbF) solder wire sizes are recommended for service of this product: 0.3mm, 0.6mm and 1.0mm.