25
8 Measurements and Adjustments
8.1.
Adjustment Procedure
8.1.1.
Driver Set-up
8.1.1.1.
Item / Preparation
1. Input a white signal to plasma video input.
2. Set the picture controls as follows.
Picture menu: Dynamic
PNR: Min
Aspect: 16:9
Caution
1. First perform Vsus adjustment.
2. The Vscn voltages are measured from the Vad (Vad_base), but may be measured from the GND (GND_base) in an 
unavoidable case.
8.1.1.2.
Adjustments
Adjust driver section voltages referring the panel data on the panel data label.
Check or adjust the following voltages with the multimeter.
*See the Panel label.
Name
Test Point
Voltage
Volume
Remarks
Vsus
TPVSUS (SS)
Vsus ± 2V
R737 (P)
*
Ve
TPVE (SS)
Ve ± 2.5V
Fixed
*
Vset
TPVSET (SC)
290V ± 9V
Fixed
Vad
TPVAD (SC)
-180V ± 2V
VR16600 (SC)
Vscn
TPVSCN (SC)
Vad_base : + 145V ± 4V
GND_base : - 35V ± 6V
Fixed
Vda
TPVDA (P)
60V + 1V, - 2V
Fixed
26
8.1.2.
Initialization Pulse Adjust 
1. Input the White signal to plasma video input.
2. Set the picture controls as follows.
Picture menu : Dynamic
PNR : Min
Aspect : 16:9
3. Connect Oscilloscope to TPSC1 (SC).
Check the voltage (T2) at 100
μs period on the down slop.
8.1.3.
P.C.B. (Printed Circuit Board) exchange
8.1.3.1.
Caution
1. To remove P.C.B., wait 1 minute after power was off for discharge from electrolysis capacitors.
8.1.3.2.
Quick adjustment after P.C.B. exchange
Adjust the following voltages with the multimeter.
*See the Panel label.
Caution: 
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
Test point
Volume
Level
T2
TPSC1 (SC)
VR16601 (SC)
210 V ± 10 V
P.C.B.
Name
Test Point
Voltage
Volume
Remarks
P Board
Vsus
TPVSUS (SS)
Vsus ± 2V
R737 (P)
*
SC Board
Vad
TPVAD (SC)
-180V ± 2V
VR16600 (SC)
A Board
White balance and Sub brightness for RF and 1080i signals
27
8.1.4.
Adjustment Volume Location
8.1.5.
Test Point Location
28
8.2.
Adjustment
8.2.1.
Sub-Contrast adjustment
Name of measuring instrument
Connection
Remarks
RF generator
Base Band signal generator
HD signal generator
Steps
Remarks
Adjustment of TV (RF system)
Note:
In adjustment, you must setting to modulation of signal at 85%.
1. Receive a RF PAL 100% Full White or Split Colour bar shown as below.
2. Goes into service adjustment mode.
3. Push a [ 1 ] or [ 2 ] key, and goes into adjustment mode for [ CONTRAST ].
Adjustment
1. The colour key yellow button of remote control is pushed.
2. The OSD character of sub-contrast becomes red.
(Inside under automatic adjustment)
3. The OSD character of sub-contrast returns to black.
4. End.
Ref.:
RF signal modulation spec.
UK models: 80%
Other models: 90%
Note:
Sub-contrast adjustment is unadjusted 
for AV/ HD input.
But, when needing the adjustment cho-
sen manually, please refer to [ alterna-
tive method ].
Page of 123