21
7.12. Remove the SS2-Board
1. Remove the Tuner unit. (See section 7.4.)
2. Disconnect the bridge connector (SS22-SS24) and dis-
connect the flexible cable (SS58).
3. Remove the screws (
×2 
) and remove the SS2-Board. 
7.13. Remove the SS-Board
1. Remove the Tuner unit. (See section 7.4.)
2. Unlock the cable clampers to free the cable.
3. Disconnect the connectors (SS3, SS11 and SS23).
4. Disconnect the flexible cable (SS53A).
5. Disconnect the bridge connector (SS22-SS24).
6. Remove the screws (
×5 
) and remove the SS-Board.
7.14. Remove the Hanger metals and
the Stand brackets
1. Remove the Plasma panel section from the servicing
stand and lay on a flat surface such as a table (covered
by a soft cloth) with the Plasma panel surface facing
downward.
2. Remove the Hanger metals (L, R) fastening screws (
×4
 each) and remove the Hanger metals (L, R).
3. Remove the Stand brackets (L, R) fastening screws (
×4
 each) and remove the Stand bracket metals (L, R)
and the Stand brackets (L, R).
7.15. Remove the C1-Board
1. Remove the Control button unit. (See section 7.7.)
2. Remove the Hanger metal R and the Stand bracket R.
(See section 7.14.)
3. Remove the flexible cables holder fastening screws (
×8
).
4. Disconnect the flexible cables (CB1, CB2, CB3 and CB4).
5. Disconnect the connector (C14).
6. Disconnect the flexible cable (C10).
7. Remove the screws (
×4 
) and remove the C1-Board.
22
7.16. Remove the C2-Board
1. Remove the Tuner unit. (See section 7.4.)
2. Remove the Hanger metal L and the Stand bracket L.
(See section 7.14.)
3. Remove the flexible cables holder fastening screws (
×8
).
4. Disconnect the flexible cables (CB5, CB6, CB7 and CB8).
5. Disconnect the flexible cables (C20, C21 and C22).
6. Disconnect the connectors (C23 and C25).
7. Remove the screws (
×4 
) and remove the C2-Board.
7.17. Remove the Plasma panel sec-
tion from the Cabinet assy
(glass)
1. Remove the cabinet assy and the plasma panel fastening
screws (
×2 ).
2. For leaving the plasma panel from the front frame, pull the
bottom of the cabinet assy forward, lift, and remove.
3. Remove the Rear cover hooks (L, R).
23
7.18. Remove the S-Board
1. Remove the Cabinet assy. (See section 7.17.)
2. Remove the S-Board shield case.
3. Remove the screws (
×2 
) and remove the S-Board
unit.
4. Disconnect the connector (S1).
5. Remove the Power button.
6. Remove the screw (
×1 
) and remove the S-Board.
7.19. Remove the Front glass
1. Remove the Cabinet assy. (See section 7.17.)
2. Remove the S-Board. (See section 7.18.)
3. Remove the screws (
×5 ).
4. Remove the Glass holder bottom rear.
5. Remove the screws (
×4 ).
6. Remove the Glass holder side (L, R).
7. Remove the screws (
×7 ).
8. Remove the Glass holder top rear.
9. Remove the Front glass.
10. Remove the Glass holder bottom front and Glass holder
top front.
7.20. Remove the K-Board
1. Remove the Front glass. (see section 7.19)
2. Remove the claw (
×1 ).
3. Disconnect the connector (K1) and remove the K-Board
from LED Panel.
24
7.21. Replace the plasma panel
Caution:
A new plasma panel itself without Hanger metals is
fragile.
To avoid the damage to new plasma panel, carry a new
plasma panel taking hold of the Hanger metals after
assembling the Hanger metals and the Stand brackets.
1. Place a carton box packed a new plasma panel on the flat
surface of the work bench.
2. Open a box and without taking a new plasma panel;
Attach the C1-Board and the C2-Board, connect the flexi-
ble cables from the plasma panel to the C1-Board and the
C2-Board, and fit the flexible cable holders.
3. Attach the Hanger metals and the Stand brackets to the
new plasma panel.
4. Place the plasma panel on the servicing stand taking hold
of the Hanger metals.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
*When fitting the cabinet assy, be careful not to allow any 
debris, dust or handling residue to remain between the 
front glass and plasma panel.
Page of 123