13
TH-50PF11EK
6.1.4.
MS mode
Select the MS mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
To exit the MS mode, press the R button on the remote control.
Caution:
Market Select should be set after exchange of DN-Board.
Destination number
Default setting
6.1.5.
ID mode
Select the ID mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
To exit the ID mode, press the R button on the remote control.
Number
Destination
Number
Destination
0
Japan
16
--
1
North America
17
--
2
Europe
18
China
3
Others
19
China (Hotel)
4
Britain
20
Russia
5
Taiwan
21
Russia (Hotel)
6
Thailand
22
Hong Kong
7
--
23
--
8
Japan (Hotel)
24
--
9
North America (Hotel)
25
--
10
Europe (Hotel)
26
--
11
--
27
--
12
Britain (Hotel)
28
Middle East/Hong Kong
13
--
29
Middle East/Hong Kong (Hotel)
14
Thailand (Hotel)
30
Australia
15
--
31
Australia (Hotel)
Number
Destination
1
North America
14
TH-50PF11EK
6.2.
IIC mode structure (following items value is sample data)
15
TH-50PF11EK
7 Troubleshooting Guide
7.1.
Self Check
7.1.1.
Display Indication
1. Self-check is used to automatically check the bus line
controlled circuit of the Plasma display.
2. To get into the Self-check mode, press the volume down
button on the customer controls at the bottom of the set,
at the same time pressing the OFF-TIMER button on the
remote control, and the screen will show.
If the IIC ports have been checked and found to be incorrect
Or not located then “ - - ” will appear in place of “ OK ”
“ 01 ” in the line of the “ PTCT ” means the number of blinks of
the Power LED is 1. (Reference to 7.1.2)
“ H09 ” in the line of the “ PTCT ” is the error code.
To exit the CAT mode switch off the main power.
Note:
The line of the “ PTCT ” displays when you get into the Self-
check mode for the first time only after the Power LED
blinks.
16
TH-50PF11EK
7.1.2.
Power LED Blinking timing chart
1. Subject
Information of LED Blinking timing chart.
2. Contents
When an abnormality has occurred to the unit, the protection circuit operates and resets to the stand by mode. At this time,
the defective block can be identified by the number of blinks of the Power LED on the front panel of the unit.