Panasonic TH-46PY8P / TH-46PZ8B / TH-46PZ8E Service Manual ▷ View online
13
6.2.
Power LED Blinking timing chart
1. Subject
Information of LED Flashing timing chart.
2. Contents
When an abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the
defective block can be identified by the number of blinks of the Power LED on the front panel of the unit.
defective block can be identified by the number of blinks of the Power LED on the front panel of the unit.
14
6.3.
No Power
First check point
There are following 2 states of No Power indication by power LED.
There are following 2 states of No Power indication by power LED.
1. No lit
2. Red is lit then turns red blinking a few seconds later. (See 6.2.)
2. Red is lit then turns red blinking a few seconds later. (See 6.2.)
15
6.4.
No Picture
16
6.5.
Local screen failure
Plasma display may have local area failure on the screen. Fig-1 is the possible defect P.C.B. for each local area.