7.13. Remove the SS-Board
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (SS11, SS12, SS33, SS34
and SS35).
3. Disconnect the flexible cables (SS61, SS63, SS64 and
SS66).
4. Remove the screws (
×6 
) and remove the SS-Board.
7.14. Remove the Stand brackets
1. Remove the Plasma panel section from the servicing
stand and lay on a fiat surface such as a table (covered)
with the Plasma panel surface facing downward.
2. Remove the Stand brackets (L, R) fastening screws (
×5
each) and remove the Stand brackets (L, R).
7.15. Remove the D-Board
1. Remove the Tuner unit. (See section 7.7.)
2. Disconnect the connectors (D3, D5 and D25).
3. Disconnect the flexible cables (D20, D31, D32 and D33).
4. Remove the screws (
×4 
) and remove the D-Board.
7.16. Remove the C1-Board
1. Remove the Tuner unit. (See section 7.7.)
2. Remove the Stand bracket R. (See section 7.14.)
3. Remove the DD-Heat-sink fastening screws (
×12 ).
4. Remove the DD-Heat-sink (
×6).
5. Disconnect the flexible cables (CB1, CB2, CB3, CB4,
CB5 and CB6).
6. Disconnect the flexible cables (C10 and C11).
7. Remove the screws (
×5 
) and remove the C1-Board.
22
7.17. Remove the C2-Board
1. Remove the Tuner unit. (See section 7.7.)
2. Remove the stand bracket L. (See section 7.14.)
3. Remove the DD-Heat-sink fastening screws (
×10 ).
4. Remove the DD-Heat-sink (
×5).
5. Disconnect the flexible cables (CB7, CB8, CB9, CB10
and CB11).
6. Disconnect the flexible cables (C20, C21, C22 and C26).
7. Remove the screws (
×5 
) and remove the C2-Board.
7.18. Remove the C3-Board
1. Remove the DD-Heat-sink fastening screws (
×8 ).
2. Remove the DD-Heat-sink (
×4).
3. Disconnect the flexible cables (CB12, CB13, CB14 and
CB15).
4. Disconnect the flexible cable (C36).
5. Disconnect the connectors (C33 and C35).
6. Remove the screws (
×4 
) and remove the C3-Board.
7.19. Remove the Front bracket
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (A51). (See section 7.7.)
3. Remove the screws (
×2 , 
×2 
) and remove the
Front bracket.
7.20. Remove the G-Board
1. Remove the Front bracket. (See section 7.19.)
2. Remove the screws (
×2 ).
3. Remove the screws (
×2 ).
4. Remove the Front shield case front.
5. Remove the screws (
×3 ).
6. Disconnect the connector (G51) and remove the G-
Board.
23
7.21. Remove the Speakers
1. Disconnect the relay connectors
2. Remove the screws (
×4 
 each) and remove the
Speaker (L, R).
7.22. Remove the Plasma panel sec-
tion from the Cabinet assy
(glass)
1. Remove the stand brackets (left, right) fastening screw
(
×1  
each).
2. Remove the cabinet assy and the plasma panel fastening
screws (
×8 , 
×6 ).
3. For leaving the plasma panel from the front frame, pull the
bottom of the cabinet assy forward, lift, and remove.
4. Remove the spacers and spacer rings (
×6 ).
Caution :
• Please confirm the installation place of Spacer and
Spacer Ring when you exchange the Plasma Panel, and
install Spacer and Spacer Ring in an original installation
place after exchanging the Plasma Panel.
24
7.23. Remove the S-Board
1. Remove the Cabinet assy. (See section 7.22.)
2. Disconnect the connector (S1).
3. Remove the screws (
×2 
) and remove the S-Board
metal frame.
4. Remove the screws (
×2 
) and remove the S-Board.
7.24. Remove the K-Board
1. Remove the Cabinet assy. (See section 7.22.)
2. Remove the S-Board. (See section 7.23.)
3. Remove the screws (
×2 ).
4. Disconnect the connector (K1) and Remove the K-Board.
7.25. Remove the plasma panel (fin-
ished)
1. Place the new plasma panel (finished) on the flat surface
of the table (covered by a soft cloth), with the plasma
panel surface facing downward.
2. Attach the C1-Board, C2-Board and the C3-Board, con-
nect the flexible cables (
×15) from the plasma panel to the
C1-Board, C2-Board and the C3-Board, and fit the flexi-
ble cable holders.
3. Attach the Hooks (left, right) and fit the stand brackets (L,
R) to the new plasma panel.
4. Place the plasma panel section on the servicing stand.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
*When fitting the cabinet assy, be careful not to allow any 
debris, dust or handling residue to remain between 
the front glass and plasma panel.