DOWNLOAD Panasonic TH-42PV500E / TH-42PV500B / TH-37PV500E / TH-37PV500B Service Manual ↓ Size: 37.64 MB | Pages: 127 in PDF or view online for FREE

Model
TH-42PV500E TH-42PV500B TH-37PV500E TH-37PV500B
Pages
127
Size
37.64 MB
Type
PDF
Document
Service Manual
Brand
Device
Plasma / DIGITAL HIGH DEFINITION PLASMA TELEVISION
File
th-42pv500e-th-42pv500b-th-37pv500e-th-37pv500b.pdf
Date

Panasonic TH-42PV500E / TH-42PV500B / TH-37PV500E / TH-37PV500B Service Manual ▷ View online

8 Self Check
 1. Self-Check is used to automatically check the bus lines and hexadecimal code of the TV set.
 2. To get into the Self -Check mode press the Down (
) button on the customer controls at the front of the set, at the same
time pressing the Status button on the remote control, and the screen will show :
If the CCU ports have been checked and found to be incorrect or not located then “--” will appear in place of “O.K.”.
Display
Ref.No.
Description
Board
MEM
IC1107
EEPROM
DG-Board
GC4P
IC4054
Global Core Processor
DG-Board
GC3FS
IC4013
Global Core for Sub
DG-Board
HAD
IC4012
OSD RGB A/D
DG-Board
AVSW1
IC2105
Video SW
H-Board
AVSW2
IC3005
Audio SW
H-Board
Tun1
TU001
Tuner
TA-Board
VIF
-
-
-
DAC1
IC1106
Ext. DAC
DG-Board
DAC2
IC1116
Ext. DAC
DG-Board
DAC3
IC3006
Ext. DAC
H-Board
DAC4
-
-
-
MSP
IC2106
Multi Sound Processor
H-Board
SOUND
IC2300
Sound Control
Z-Board
PANEL
IC9003
Convert Micom
D-Board
SDM
SD-Module
MPEG4/PHOTO view, SD recording
SD-Module
HDMI
IC5003
HDMI I/F Reciever
DV-Board
ADV
IC4005
10bit A/D
DG-Board
33
TH-42PV500E / TH-42PV500B / TH-37PV500E / TH-37PV500B
8.1. Power LED Blinking timing chart
 1. Subject
Information of LED Flashing timing chart.
 2. Contents
When an abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the
defective block can be identified by the number of blinkes of the Power LED on the front panel of the unit.
8.2. No Power
First check point
There are following 3 states of No Power indication by power LED.
 1. No lit
 2. Green is lit then turns red blinking a few seconds later.
 3. Only red is lit.
 1. No lit
34
TH-42PV500E / TH-42PV500B / TH-37PV500E / TH-37PV500B
8.3. No Picture
35
TH-42PV500E / TH-42PV500B / TH-37PV500E / TH-37PV500B
8.4. Local screen failure
Plasma display may have local area failure on the screen. Fig-1 is the possible defect P.C.B. for each local area.
Fig-1
36
TH-42PV500E / TH-42PV500B / TH-37PV500E / TH-37PV500B
Page of 127
Display