2.1.2 Leakage Current Hot Check (See 
Figure 1
 .) 
TOP
 
PREVIOUS
 
NEXT
 
1.  Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this 
check.
2.  Connect a 1.5k
, 10 watts resistor, in parallel with a 0.15μF capacitors, between each 
exposed metallic part on the set and a good earth ground such as a water pipe, as shown in 
Figure 1
 .
3.  Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across 
the resistor.
4.  Check each exposed metallic part, and measure the voltage at each point.
5.  Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6.  The potential at any point should not exceed 0.75 volts RMS. A leakage current tester 
(Simpson Model 229 or equivalent) may be used to make the hot checks, leakage current must 
not exceed 1/2 milliamp. In case a measurement is outsideof the limits specified, there is a 
possibility of a shock hazard, and the equipment should be repaired and rechecked before it is 
returned to the customer.
TOP
 
PREVIOUS
 
NEXT
 
3 Prevention of Electro Static Discharge (ESD) to Electrostatically 
Sensitive (ES) Devices
TOP
 
PREVIOUS
 
NEXT
 
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. 
Examples of typical ES devices are integrated circuits and some field-effect transistorsand semiconductor "chip" components. The following techniques should be used 
to help reduce the incidence of component damage caused by electro static discharge (ESD).
1.  Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your body by touching a known earth 
ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap, whichshould be removed for potential shock reasons prior to 
applying power to the unit under test.
2.  After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as alminum foil, to prevent electrostatic 
charge buildup or exposure of the assembly.
3.  Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4.  Use only an anti-static solder removal device. Some solder removal devices not classified as "anti-static (ESD protected)" can generate electrical charge 
sufficient to damage ES devices.
5.  Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6.  Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most replacement ES devices are 
packaged with leads electrically shorted together by conductive foam, alminum foil or comparableconductive material).
7.  Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material to the chassis or circuit assembly 
into which the device will be installed.
Caution
 
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8.  Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise hamless motion such as the brushing together of your clothes fabric 
or the lifting of your foot from a carpeted floor can generate static electricity (ESD) sufficient todamage an ES device).
TOP
 
PREVIOUS
 
NEXT
 
4 About lead free solder (PbF)
TOP
 
PREVIOUS
 
NEXT
 
Note: Lead is listed as (Pb) in the periodic table of elements.
 
In the information below, Pb will refer to Lead solder, and PbF will refer to Lead Free Solder.
 
The Lead Free Solder used in our manufacturing process and discussed below is (Sn+Ag+Cu).
 
That is Tin (Sn), Silver (Ag) and Copper (Cu) although other types are available.
 
This model uses Pb Free solder in it’s manufacture due to environmental conservation issues. For service and repair work, we’d 
suggest the use of Pb free solder as well, although Pb solder may be used.
PCBs manufactured using lead free solder will have the PbF within a leaf Symbol 
 stamped on the back of PCB.
Caution 
●     
Pb free solder has a higher melting point than standard solder. Typically the melting point is 50 ~ 70 °F (30~40 °C) higher. 
Please use a high temperature soldering iron and set it to 700 ± 20 °F (370 ± 10 °C).
●     
Pb free solder will tend to splash when heated too high (about 1100 °F or 600 °C).
If you must use Pb solder, please completely remove all of the Pb free solder on the pins or solder area before applying Pb 
solder. If this is not practical, be sure to heat the Pb free solder until it melts, before applying Pb solder.
●     
After applying PbF solder to double layered boards, please check the component side for excess solder which may flow 
onto the opposite side. (see figure below)
Suggested Pb free solder
 
There are several kinds of Pb free solder available for purchase. This product uses Sn+Ag+Cu (tin, silver, copper) solder. 
However, Sn+Cu (tin, copper), Sn+Zn+Bi (tin, zinc, bismuth) solder can also beused.