Device
Plasma / GPH14DMON CHASSIS
File
th-42ph30er.pdf
Date

Panasonic TH-42PH30ER Service Manual ▷ View online

13
TH-42PH30ER
6.1.2.
CD mode
Select the CD mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
Memory data change
To exit the CD mode, press the R button on the remote control.
6.1.3.
SD mode
Select the SD mode by Up/Down button on the remote control at the front page of CAT mode and then press the Action button on
the remote control.
To exit the SD mode, press the R button on the remote control.
14
TH-42PH30ER
6.1.4.
MS mode
Select the MS mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
To exit the MS mode, press the R button on the remote control.
Caution:
Market Select should be set after exchange of A-Board.
Destination number
Default setting
6.1.5.
ID mode
Select the ID mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
To exit the ID mode, press the R button on the remote control.
Number
Model (Destination)
0
42/50PH30 (Japan)
1
42/50PH30U (North America)
2
50PH30E (Europe)
3
42/50PH30W (Asia, Oceania, ME)
18
42/50PH30C (China)
20
42/50PH30ER (Europe, CIS)
Number
Destination
1
North America
15
TH-42PH30ER
6.2.
IIC mode structure (following items value is sample data)
16
TH-42PH30ER
7 Troubleshooting Guide
7.1.
Self Check
7.1.1.
Display Indication
1. Self-check is used to automatically check the bus line
controlled circuit of the Plasma display.
2. To get into the Self-check mode, press the volume down
button on the customer controls at the bottom of the set,
at the same time pressing the OFF-TIMER button on the
remote control, and the screen will show.
If the IIC ports have been checked and found to be incorrect
Or not located then “ - - ” will appear in place of “ OK ”
“ 01 ” in the line of the “ PTCT ” means the number of blinks of
the Power LED is 1. (Reference to 7.1.2)
“ H09 ” in the line of the “ PTCT ” is the error code.
To exit the CAT mode switch off the main power.
Note:
The line of the “ PTCT ” displays when you get into the Self-
check mode for the first time only after the Power LED
blinks.
Page of 124