6 Installation Instructions
6.1.
Connections
This section explains the ports and connectors on the unit.
Connections for AC Adaptor/LAN/PC
CAUTION
Optional AC Adaptor
• Use the following Panasonic AC adaptor.
     - KX-A239CE (PQLV206CE)
• The AC adaptor is used as the main disconnect device. Ensure that the AC outlet is installed near the unit and is easily acces-
sible.
When connecting a headset
• Ensure that the headset cord has slack and is not pulled tight during use to prevent damage to the connectors.
• Cords used to connect devices to the EHS jack or headset jack must be less than 3 m in length.
Notice
• It is recommended that you use the following headsets:
- Wired headsets
   Panasonic RP-TCA400 and RP-TCA430
When selecting Ethernet cables (not included)
• Use flexible, high-quality, snagless (without strain relief) cables. Do not use cables with coating that may tear or crack when
bent.
To prevent damage to the cables, use cables that do not protrude from the bottom of the base.
Connect the cables as shown in the following illustration.
• Use a straight CAT 5 (or higher) Ethernet cable (not included) that is 6.5 mm in diameter or less.
19
KX-UT113RU/KX-UT113RU-B/KX-UT123RU/KX-UT123RU-B
When connecting to a switching hub
• If PoE is available, an AC adaptor is not needed.
• This unit complies with the PoE Class 2 standard.
When connecting a PC
• Only a PC can be connected to the PC port. Other SIP phones, or network devices such as routers or switching hubs, cannot
be connected.
• The PC port does not support PoE for connected devices.
When connecting cables and the AC adaptor
• Ensure that the Ethernet cables and the AC adaptor cord are clamped to prevent damage to the connectors.
Connections for Handset
20
KX-UT113RU/KX-UT113RU-B/KX-UT123RU/KX-UT123RU-B
7 Test Mode
7.1.
Peer to Peer Test Mode
This is for VoIP communication TEST.
Setting of Unit are required before communication test by Peer to Peer Mode. 
Refer to from 7.1.1 Preparation (P.20) to 7.1.2 Connection for Test (P.21) . 
7.1.1.
Preparation
Prepared device:
• Unit (for Test phone and Reference phone): Each one
• Ethernet (LAN) cable
Set up unit in test mode by key control
1. Connect a power plug (AC adaptor/PoE).
2. Push [2][6][*] within 4 seconds after Ringer Green LED turns off.
3. Release the three keys after beep.
    The LCD displays [please wait ...] after a short time.
4. Then the LCD displays [P2P Mode Setting: Normal]. Choose the any mode.
 [1][Enter]:TEST mode 1 (IP Address:192.168.0.241)
 [2][Enter]:TEST mode 2 (IP Address:192.168.0.240)
 [0][Enter]:normal mode
5. After that, disconnect and reconnect the power plug.