DOWNLOAD Panasonic KX-UDT111RU (serv.man3) Service Manual ↓ Size: 1.95 MB | Pages: 64 in PDF or view online for FREE

Model
KX-UDT111RU (serv.man3)
Pages
64
Size
1.95 MB
Type
PDF
Document
Service Manual
Brand
Device
PBX / DECT PORTABLE STATION
File
kx-udt111ru-sm3.pdf
Date

Panasonic KX-UDT111RU (serv.man3) Service Manual ▷ View online

33
KX-UDT111RU
9.7.
STM (Start Monitor)
STM means a power on sequence of software .
and it can check which part is NG 
Step
Software condition
Software start up
Initialize STM
Initialize Clock
Initialize DAIF
Initialize GPIO
Initialize SPI
Initialize RDS
Initialize SPI
Initialize RDS
Initialize Battery
Initialize KBS
System start judgment
Initialize RDS
interrupt is effective
Initialize RF
Initialize DSP
STM
High
Low
High
Low
High
Low
High
Low
High
Low
High
Low
High
Low
High
SRAM
-
-
-
-
-
-
Access
-
Access
Access
-
Access
Access
Access
Access
Access
Low
FLASH
-
-
-
-
-
-
Access
-
Access
-
-
-
-
-
Access
Access
Figure of image of STM port
Waveform of STM port
STM
SRAM_CS/ (IC100 81pin)
FLASH_CS/ (IC102 1pin)
By the Fatal reset, SMT port 
may toggle instantly at this point.
34
KX-UDT111RU
9.8.
Error Message
9.8.1.
Need Repair
* NeedRepair7 is primary battery detection. 
* NeedRepair8 is a confirmation number. This time, there is no implemention.
Display example
9.8.2.
“ERROR 1”, “ERROR 2”
Display example
Need Repair No.
Error
Explanation
Remedy
1
Flash Error
Flash unimplemented / start failure
Flash failure
Fail to start Flash 
Change chassis 
2
Flash ADM Error
Flash ADM block error
Flash failure
Flash management information verification NG
Change chassis
3
Flash Data Error
Flash Data block error
Flash failure
Adjustment data block NG
Change chassis
4
Flash Record Error
Flash Write error
Flash failure
Writing to Flash NG
Change chassis
5
Application Error
Character input mode range error
Flash failure
Check if it's in the range of switching character input mode for phone-
book can be done.
It occurs when adjustment level is out of range. 
Usually this doesn't happen. So it is considered as Flash failure.
Change chassis
6
Download File Error
Download file mismatch 
Flash failure
It occurs when the designation of renewal file of AirDownload is wrong.
Usually this doesn't happen. So it is considered as Flash failure.
Change chassis
9
Download Module Error
Time out as rewriting module while 
AirDownloading
It occurs when only a part of modules are rewritten and failed to down-
load specified times.
Change chassis
10
Const Data Error
Const data Version mismatch
Version mismatch of program and external Flash fixed data
Change chassis
ERROR No.
Error
Explanation
Remedy
1
Fail to delete Flash when AirDownloading.
Flash failure
Fail to delete PFlash or DFlash
Change chassis 
2
Write failure of Flash when AirDownloading.
Flash failure
Fail to write on PFlash or Dflash
Change chassis
Need Repair
2
< ERROR 1>
35
KX-UDT111RU
10 Disassembly and Assembly Instructions
10.1. Handset
10.2. Charger Unit
Shown in Fig.-
To Remove
Remove
1
CABINE COVER
Screws (  
×  )..........(A) × 4
2
Main P.C. Board
Main P.C. Board
Shown in Fig.-
To Remove
Remove
3
LOWER CABINET
Screws (  
×  )..........(B) × 1
4
Main P.C. Board
Main P.C. Board
36
KX-UDT111RU
11 Measurements and Adjustments
11.1. Check Procedure (Handset)
11.1.1. Preparation
11.1.1.1. Equipment Required
• DECT tester: Rhode & Scorers, CTS 60 is recommended.
• Frequency counter: it must be precise to be able to measure 1Hz (precision; ±4ppm).
Hewlett Packard, 53131A is recommended.
• DC power: it must be able to output at least 1A current under 2.6V for Handset, 9V for Tool.
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope
11.1.1.2. Tool and PC
• EEPROM serial Tool
Tool: PSZZ1TD7896M
• PC which has “flash program.exe”. Version 1.0
11.1.2. PC Setting
11.1.2.1. Connections
Page of 64