11.4. INTERCOM CIRCUIT
11.4.1. INTERCOM CIRCUIT
1) Composition
This is composed of the following circuits:
a) +15V power source for the extension telephones
b) Hook detect for SLT and pulse dialing detect
c) Bell ring trip section
2) Circuit operation
a) Power supply to the telephone
With the telephone off hook, a DC loop is formed, and current is supplied to the telephone. This circuit is limited to about 30mA
by Q200, Q202, R202, R204 and Q201, Q203, R203, R205.
+15V
→R204→R202→Q200→RL201→telephone→RL201→Q201→R203→R205→-15V
b) Hook detect for SLT and pulse dialing detect
When the telephone handset is taken off, DC loop is formed and the collector of U200 3,6 pin change to L from H.
The ASIC detects the off hook condition.
When the handset is replaced back on hook, the DC loop is interrupted and collector of U200 3,6 pin change to H from L and
EXT Pulse dialing is input either in the on hook or off hook condition, and the break number (on hook condition) is counted and
read as the dial number.
c) Bell ringing trip section
When the telephone is a signal line telephone, extension calling is executed by means of a ringing signal. When the ringing
signal is supplied, RL201 turns ON and the current flows are as follows:
Bell transformer
→ ringing signal line → RL201 → telephone → R206 → -15V → Bell transformer
29
KX-TES824UA / KX-TEM824UA /
11.5. POWER FAILURE THROUGH CALL SWITCHING CIRCUIT
11.5.1. Circuit operation
If an AC power failure lasts longer than one second (momentary power failure), the COL is directly connected to the extension.
The COL1 will be connected with EXT101.
When power failure, RL200 switches from EXT-line to CO [T/R].
*In case of KX-TEM824, and the COL4 will be connected with EXT109.
*In case of KX-TE82480, and the CO7 will be connected with EXT117.
30
KX-TES824UA / KX-TEM824UA /
11.6. DATA COMMUNICATION CIRCUIT
11.6.1. Composition
This circuit is composed of the ASIC and the data communication interface circuits for the ICM circuit.
11.6.2. Circuit Operation
1) Data Communication of ASIC
The APT I/f module is built into the CPU. It is for the APT communication of one block (8ch) and has the module of three blocks
(24ch) at maximum.
Selection signal of 3 bits to select 1ch out of 8chs is common to each block.
The APT I/f module switches the communication point every 4ms in the ports 1-8/9-16/17-24 of the extension as follows:
#101
→#102→#103→#104.....→#108→#101.....,
#109
→#110→#111→#112.....→#116→#109.....,
#117
→#118→#119→#120.....→#124→#117.....,
In the case where the extension is not connected with the APT, it is recognized as an SLT connection and a dummy
communication is performed.
Interface block diagram of ASIC and ICM
31
KX-TES824UA / KX-TEM824UA /
2) Data Communication of ASIC and PITS
When ASIC send the request signal to the proprietary telephone and after receiving the key input information (19 pulses) from
the proprietary telephone and sending data (47 pulses) for LED control. 4bit CPU will receive acknowledge signal from the
proprietary telephone.
a) Reception
The data from the proprietary telephone is received via H and L lines along the path shown below.
H.L line
→ C208 → IC200 →T201 → R235 → Q210 → ASIC
b) Transmission
The data to the proprietary telephone is transmitted along the following Path.
ASIC
→ Q209 → Q215 → T201 → IC200 → C208 → H.L line
32
KX-TES824UA / KX-TEM824UA /
Page of 127
Display