DOWNLOAD Panasonic KX-TES824UA / KX-TEM824UA / KX-TE82461X / KX-TE82474X / KX-TE82480X / KX-TE82483X / KX-TE82491X / KX-TE82492X / KX-TE82493X / KX-A227X / KX-TES824UAPP / KX-TEM824UAPP Service Manual ↓ Size: 14.67 MB | Pages: 127 in PDF or view online for FREE

Model
KX-TES824UA KX-TEM824UA KX-TE82461X KX-TE82474X KX-TE82480X KX-TE82483X KX-TE82491X KX-TE82492X KX-TE82493X KX-A227X KX-TES824UAPP KX-TEM824UAPP
Pages
127
Size
14.67 MB
Type
PDF
Document
Service Manual
Brand
Device
PBX / ADVANCED HYBRID SYSTEM
File
kx-tes824ua-kx-tem824ua-kx-te82461x-kx-te82474x-kx.pdf
Date

Panasonic KX-TES824UA / KX-TEM824UA / KX-TE82461X / KX-TE82474X / KX-TE82480X / KX-TE82483X / KX-TE82491X / KX-TE82492X / KX-TE82493X / KX-A227X / KX-TES824UAPP / KX-TEM824UAPP Service Manual ▷ View online

11 CIRCUIT OPERATION
11.1. POWER SUPPY CIRCUIT
11.1.1. The function of the power unit are listed below
AC-DC Inverter Function
This function isolates and transduces the AC input voltage to
DC input and output of DC27V.
DC-DC Converter Function
This function outputs DC+15V, -15V and 3.3V from the
inputted DC27V.
Ringing Signal Output Function
Based on the 20/25Hz sine wave signal output from KX-
TES824/KX-TEM824, this function generates ringing and
supplies to the system.
AC Power Failure Detection
This function detects any cut off of the AC power supply and
outputs an AC alarm signal to the CPU.
Battery Back Up Adaptor Function
This function connects battery and service unit without battery
adaptor, only needs a cable connected to the battery and
service unit.
21
KX-TES824UA / KX-TEM824UA /
11.1.2. Control Section
1) AC-DC Inverter Function
The AC input voltage is rectified and smoothed by D10-13 and C5. The obtained DC voltage is converted into a rectangular wave
by the switching transistor Q1, then isolated and transduced by T1. This converted rectangular wave is rectified and smoothed by
D101 and C101 to output DC27V. The DC27V is transmitted to the primary side by PC1 and then PWM- controlled to keep
constant. The switching frequency of Q1 is approximately 100KHz (70KHz~160KHz).
2) DC-DC Inverter Function
The DC27V as input is converted into a rectangular wave by the switching transistor Q201, then isolated and transduced by T2.
DC+15V, -15V and 3.3V are outputted by a rectification smoothing circuit composed of D401, D301, D701, C401, C301 and C702.
The +3.3V of the three outputs is PWM-controlled by IC201 to keep constant.The switching frequency of the Q2 is approx. 55 KHz.
3) Ringing signal output function
Ringing signal (20/25Hz, 75Vac from main board) is amplified in power by power amplifier circuits (including of IC501, R601~R608,
C601~C603).
Ringing signal amplified in power is transmitted to the ringing transformer through pin 4 of CN601.
4) AC Power Failure Detection
AC power failure is detected by D31~D32, R33~R41, C31, PC31.
When AC power is on, PC31 is on.
When AC power is turned off, PC31 is off.
5) Battery back up function
This back up battery adaptor circuit has DC supply function, from battery (+24V) to service unit and DC charge from service unit
to battery (+24V). Charge current is typ. 0.4A.
22
KX-TES824UA / KX-TEM824UA /
11.2. CO INTERFACE CIRCUIT
11.2.1. Composition
This is composed of the following circuit:
1) Bell signal detection
2) DC loop formation circuit
3) Pulse dial transmission circuit
4) CALL ID interface circuit
5) COL bidirectional amplifier circuit
1) Bell signal detection
When CO line is idle, photo coupler PC1, PC2 are OFF.
When there is an incoming signal from CO line, the current flows PC1 as in the following way.
Tip
→ L1 → R2 → PC1(1-2) → C3 → T2 → R5 → L1 → Ring: This cause pin4 of PC1 to change the level from High to low.
Ring
→ L1 → R5 → T2 → C3 → PC2(1-2) → R2 → L1 → Tip: This cause pin4 of PC2 to change the level from High to low.
23
KX-TES824UA / KX-TEM824UA /
2) DC loop formation circuit
In the off hook status, PC5 is ON.
DC loop path:
Tip
→L1→D1→D2→D3→Q10(E-C)→Q1(C-E)→R9→R8→D3→L1→Ring
At this time, the output of the photo coupler PC1 changes level from High to low.
Ring
→L1→D3→R8→R9→Q1(E-C)→Q10(C-E)→D3→D2→D1→L1→Tip
At this time, the output of the photo coupler PC2 changes level from High to low.
Afterwards, G/A monitor this change (low level to high level). If the high level continues for a specified time set by system data
programming. G/A assumes that CO line has become On hook status. And the CO line circuits is restored to the idle status.
3) Pulse dial transmission circuit
When the Off hook status, pulse dial transmission is executed by alternating On hook and Off hook. The status of On hook or
Off hook is controlled by the switching transistor Q10.
24
KX-TES824UA / KX-TEM824UA /
Page of 127
Display

Click on the first or last page to see other KX-TES824UA / KX-TEM824UA / KX-TE82461X / KX-TE82474X / KX-TE82480X / KX-TE82483X / KX-TE82491X / KX-TE82492X / KX-TE82493X / KX-A227X / KX-TES824UAPP / KX-TEM824UAPP service manuals if exist.