Panasonic KX-NT543RU / KX-NT543RU-B / KX-NT546RU / KX-NT546RU-B (serv.man2) Service Manual ▷ View online
29
KX-NT543RU/KX-NT543RU-B/KX-NT546RU/KX-NT546RU-B
Table-6
No. 10
PHY Data Error
[Check Points]
Measure the ECLK signal at TP MAINOSC.
Flat Cable(Between Main PCB and Ope PCB)
For details to 9.7.1 PHY Data Error. (P.36)
Flat Cable(Between Main PCB and Ope PCB)
For details to 9.7.1 PHY Data Error. (P.36)
[Related Parts]
IC401, IC501, X501, R552-R554, L502
R401, R402, R403, R405, R406, R410, RA403, RA511, R506,L401-L404, L407, L414, C415,
R542, L513
R401, R402, R403, R405, R406, R410, RA403, RA511, R506,L401-L404, L407, L414, C415,
R542, L513
[Related Circuit]
30
KX-NT543RU/KX-NT543RU-B/KX-NT546RU/KX-NT546RU-B
9.2.
LCD Does Not Operate
Note:
Refer to waveform (3) and (4) in Waveform (P.56)
31
KX-NT543RU/KX-NT543RU-B/KX-NT546RU/KX-NT546RU-B
9.3.
ASIC Does Not Work
9.3.1.
ASIC Data Error
Note:
Refer to waveform (17) in Waveform (P.58)
32
KX-NT543RU/KX-NT543RU-B/KX-NT546RU/KX-NT546RU-B
9.4.
Handset Does Not work
9.4.1.
Receive
9.4.2.
Send