Panasonic KX-NCP500RU Service Manual ▷ View online

113
KX-NCP500RU
13.14. IPCMPR Card No.13
KX-NCP500RU SCHEMATIC DIAGRAM No.13 (1/2)
(1)
(2)
(3)
(4)
PGND
PGND
PVIN
VOUT
C
E
B
A
D
F
3
4
2
1
5
DG
CL1910
IC1901
1 VOSENSE1
2 PLLFLTR
9
VOSENSE2
3 PLLIN
4 FCB
5 ITH1
6 SGND
7 3.3VOUT
8 ITH2
10
NC1
11
SENSE2-
12
SENSE2+
13
RUN/SS2
14
TG2
15
SW2
16
NC2
17
BOOST2
18
BG2
19
PGND
20
INTVCC
21
EXTVCC
22
BG1
23
VIN
24
BOOST1
25
SW1
26
TG1
27
PGOOD
28
RUN/SS1
29
NC3
30
SENSE1+
31
SENSE1-
32
NC4
33
Fin
CL1925
CL1945
DG
CL1957
DG
CL1959
CL1911
CL1948
CL1909
CL1903
CL1921
DG
CL1940
CL1953
CL1958
CL1901
CL1942
DG
CL1904
CL1914
DG
CL1920
CL1960
DG
CL1950
DG
CL1938
DG
CL1912
CL1908
DG
CL1937
CL1922
DG
CL1905
CL1943
DG
CL1941
DG
CL1902
CL1926
CL1954
CL1944
CL1947
CL1917
CL1946
CL1924
CL1952
DG
CL1956
CL1949
DG
DG
CL1913
CL1906
CL1923
CL1918
CL1916
DG
CL1951
CL1907
CL1939
CL1927
CL1915
CL1955
L1901
27u
L1902
15u
DL1901
1
2
3
CL1919
IC1902
1
NC1
2
XFB
3
VSENSE
4
NC2
5
NC3
6
ENABLE
7
NC4
8
XOV
9
10
11
12
13
14
15
16
17
18
19
NC5
20
21
22
23
24
NC6
25
26
27
28
29
VS2
30
ROCP
31
VS1
32
AVIN
33
AGND
34
VS0
35
POK
36
SS
37
PGND9
38
IP1901
1
2
DG
DG
D1906
1
2
D1907
1
2
D1901
1
2
D1902
1
2
R1916
0
R1914
0
R1906
15k
R1933
0
R1908
0
R1907
0
R1910
12k
R1919 510k
R1918
10
NC
R1934 10
NC
R1904
20k
R1913
20m
1
R1909
25.5k
R1915
0
R1917
0
R1905
15k
R1912
50m
1
R1911
0
R1903
63.4k
R1920
510k
C1901
15n 16 -10
C1920
100n
50
C1954
100n
50
C1914
100n
16
NC
C1915
100n
50
C1923
1n
50
C1934
10u
25
C1918 100n 16
C1927
1n
50
C1929
47u
6.3
C1926
100n
50
C1908
220p
50
C1955
10u
25
C1921
100n
50
C1909
5.6n
16
C1924
10u 10
C1910
220p
50
C1916 100n 16
C1919
100n
50
C1911
5.6n
16
C1930
10u
25
C1922
10u
25
C1925
22u
6.3
C1913
180p
50
C1907
100n
16
NC
C1933
10u
25
C1931
10u
25
C1928
47u
6.3
C1957
22u
6.3
C1917
10u
25
C1906
180p
50
C1932
22u
6.3
+15V
+15V_CON
C1956
47u
6.3
Q1901
1
2
3
4
5
6
7
8
Q1902
1
2
3
4
5
6
7
8
DC/DC PART 1
DC/DC PART 2
114
KX-NCP500RU
KX-NCP500RU SCHEMATIC DIAGRAM No.13 (2/2)
(1)
(2)
(3)
(4)
+
-
+
-
C
E
B
A
D
F
6
5
8
7
+3.3VD
+15V_CON
DG
+2.5VD
+15V
+1.25VD
+1.2VD
+1.8VD
DG
B1901
1
2
3
CL1933
CL1932
+2.5VD
TP_BAT_2
CL1964
DG
DG
DRAM_VREF
+1.2VD
+15V
DG
DG
CL1966
DG
+1.25VD
TP_BAT_1
DG
DG
+3.3VD
CL1931
CL1965
DG
DG
+15V_CON
CL1967
DG
IC1907
1 VIN
2 VSS
3 CE
5
VOUT
4
NC
PROG_B
+3.3VD_BB
CL1963
CL1934
DG
+3.3VD_B
HARD_nRESET_SW
DG
CL1962
CL1961
+1.8VD
DG
DG
CL1968
IC1908
1 VIN
2
VSS
3 CE
5
VOUT
4
NC
D1903
1
2
D1905
12
D1904
12
DG
DG
DG
nBAT_ALM
CL1929
CL1928
DG
CL1935
CL1930
CL1936
DG
DG
TP_nBAT_ALM
IC1903
4
GND
8
VCC
IC1904
1 OUT
2
VDD
3 GND
5
CD
4
NC
IC1905
1 OUT
2
VDD
3 GND
5
CD
4
NC
IC1906
1 OUT
2
VDD
3 GND
5
CD
4
NC
DL1904
1
2
3
DL1906
1
2
3
DL1905
1
2
3
DL1902
1
2
3
DL1907
1
2
3
DL1903
1
2
3
R1931
10k
R1926
10k
R1924
6.8k
R1923
10M
100m
R1901
82
1
100m
R1928
10M 100m
R1922
1k
R1927
10k
R1902
82
1
100m
R1929
4.7k
R1921
470k
R1925
2.2k
R1930
10k
C1950
2.2u
6.3
-10
C1949
10u
10
C1905
100n
16
C1902
100n
50
C1948
3.3n
50
-10
C1904
100n
16
C1937
100n
16
C1942
10u
10
C1940
10u
10
C1951
100n
16
C1944
100n
16
C1903
3.3n
50
-10
C1952
10u
10
C1935
100n
16
C1946
10u
10
C1939
10u
10
C1953
10u
10
C1947
3.3n
50
-10
C1945
100n
16
C1941
10u
10
C1938
100n
16
C1936
100n
16
C1943
100n
16
+1.25VD
+2.5VD
+1.8VD
+3.3VD
+1.2VD
+15V_CON
+3.3VD
+15V
+3.3VD
+1.2VD
+3.3VD
+2.5VD
+1.25VD
+15V
+3.3VD
+1.8VD
LAND
@SHORT-LAND
1
2
SW1901
NC
1
2
3
4
Q1903
1
2
3
IC1903
3
2
1
IC1903
5
6
7
115
KX-NCP500RU
13.15. IPCMPR Card No.14
KX-NCP500RU SCHEMATIC DIAGRAM No.14 (1/2)
(1)
(2)
(4)
(6)
(8)
(3)
(5)
(7)
(9)
(10)
(12)
(14)
(16)
(11)
(13)
(15)
(17)
(18)
(20)
(22)
(24)
(19)
(21)
(23)
(25)
(26)
(28)
(30)
(32)
(27)
(29)
(31)
(33)
(34)
(36)
(38)
(40)
(42)
(45)
(35)
(37)
(39)
(41)
(43)
(44)
(47)
(49)
(51)
(46)
(48)
(50)
C
E
B
A
D
F
3
2
1
4
5
EX1_A[0-25]
EX1_D[0-15]
EX1_D[15]
EX1_D[14]
EX1_D[13]
EX1_D[12]
EX1_D[11]
EX1_D[10]
EX1_D[9]
EX1_D[8]
EX1_D[7]
EX1_D[6]
EX1_D[5]
EX1_D[4]
EX1_D[3]
EX1_D[2]
EX1_D[1]
EX1_D[0]
EX1_A[25]
EX1_A[24]
EX1_A[23]
EX1_A[22]
EX1_A[21]
EX1_A[20]
EX1_A[19]
EX1_A[18]
EX1_A[17]
EX1_A[16]
EX1_A[15]
EX1_A[14]
EX1_A[13]
EX1_A[12]
EX1_A[11]
EX1_A[10]
EX1_A[9]
EX1_A[8]
EX1_A[7]
EX1_A[6]
EX1_A[5]
EX1_A[4]
EX1_A[3]
EX1_A[2]
EX1_A[1]
EX1_A[0]
nIREQ2_BM
BM_nRESET_SOFT
BM_nBUSY
nBS
nWE0
RnW
nRD
DG
nWE1
nCS2_BM
EX1_D[0-15]
EX1_A[0-25]
R2009
NC
1
2
3
4
5
6
7
8
R2003
NC
1
2
3
4
5
6
7
8
R2005
NC
1
2
3
4
5
6
7
8
R2004
NC
1
2
3
4
5
6
7
8
R2006
NC
1
2
3
45
6
7
8
R2008
NC
1
2
3
4
5
6
7
8
R2002
NC
1
2
3
4
5
6
7
8
R2010
NC
1
2
3
4
5
6
7
8
R2012
NC
1
2
3
45
6
7
8
R2011
NC
1
2
3
4
5
6
7
8
R2013
NC
1
2
3
4
5
6
7
8
R2007
NC
1
2
3
4
5
6
7
8
IC2004
NC
1
DIR
2
A1
3
A2
4
A3
5
A4
6
A5
7
A6
8
A7
9
A8
10
GND
11 B8
12 B7
13 B6
14 B5
15 B4
16 B3
17 B2
18 B1
19 OE
20 VCC
IC2005
NC
1
DIR
2
A1
3
A2
4
A3
5
A4
6
A5
7
A6
8
A7
9
A8
10
GND
11 B8
12 B7
13 B6
14 B5
15 B4
16 B3
17 B2
18 B1
19 OE
20 VCC
IC2002
NC
1
DIR
2
A1
3
A2
4
A3
5
A4
6
A5
7
A6
8
A7
9
A8
10
GND
11 B8
12 B7
13 B6
14 B5
15 B4
16 B3
17 B2
18 B1
19 OE
20 VCC
IC2003
NC
1
DIR
2
A1
3
A2
4
A3
5
A4
6
A5
7
A6
8
A7
9
A8
10
GND
11 B8
12 B7
13 B6
14 B5
15 B4
16 B3
17 B2
18 B1
19 OE
20 VCC
IC2001
NC
1
DIR
2
A1
3
A2
4
A3
5
A4
6
A5
7
A6
8
A7
9
A8
10
GND
11 B8
12 B7
13 B6
14 B5
15 B4
16 B3
17 B2
18 B1
19 OE
20 VCC
IC2006
NC
1
DIR
2
A1
3
A2
4
A3
5
A4
6
A5
7
A6
8
A7
9
A8
10
GND
11 B8
12 B7
13 B6
14 B5
15 B4
16 B3
17 B2
18 B1
19 OE
20 VCC
+3.3VD
+3.3VD
+3.3VD
+3.3VD
+3.3VD
+3.3VD
+3.3VD
R2031
0
NC
C2002
100n 16
NC
C2004
100n 16
NC
C2006
100n 16
NC
C2005
100n 16
NC
C2001
100n 16
NC
C2003
100n 16
NC
116
KX-NCP500RU
KX-NCP500RU SCHEMATIC DIAGRAM No.14 (2/2)
(1)
(2)
(4)
(6)
(8)
(3)
(5)
(7)
(9)
(10)
(12)
(14)
(16)
(11)
(13)
(15)
(17)
(18)
(20)
(22)
(24)
(19)
(21)
(23)
(25)
(26)
(28)
(30)
(32)
(27)
(29)
(31)
(33)
(34)
(36)
(38)
(40)
(42)
(45)
(35)
(37)
(39)
(41)
(43)
(44)
(47)
(49)
(51)
(46)
(48)
(50)
C
E
B
A
D
F
6
5
8
7
+3.3VD
DG
CL2114
CL2087
+3.3VD
DG
CL2019
CL2096
CL2070
CL2031
CL2090
CL2048
CL2118
CL2021
CL2124
CL2101
CL2026
CL2058
CL2135
CL2068
CL2074
CL2081
CL2002
CL2016
CL2122
CL2073
CL2037
CL2080
CL2134
CL2012
CL2022
CL2007
CL2063
CL2052
CL2067
CL2038
CL2004
CL2015
CL2030
CL2129
CL2113
CL2125
CL2089
CL2088
CL2042
CL2079
CL2106
CL2099
CL2009
CL2046
CL2032
CL2086
CL2115
CL2117
CL2091
CL2102
CL2133
CL2005
CL2072
CL2036
CL2003
CL2085
CL2039
CL2018
CL2108
CL2130
CL2047
CL2121
CL2077
CL2023
CL2127
CL2111
CL2001
CL2057
CL2010
CL2027
CL2120
CL2034
CL2109
CL2054
CL2044
CL2116
CL2033
CL2078
CL2043
CL2084
CL2069
CL2092
CL2071
CL2011
CL2014
CL2049
DG
CL2008
CL2064
CL2035
CL2040
CL2100
CL2059
CL2132
CL2061
CL2083
CL2045
CL2050
CL2053
CL2025
CL2093
CL2082
CL2110
CL2062
CL2098
CL2065
CL2131
CL2017
CL2076
CL2075
CL2060
CL2094
CL2051
CL2112
CL2006
DG
BM_nPRESNT
CL2056
CL2119
CL2126
CL2128
CL2041
CL2024
CL2107
CL2066
CL2105
CL2020
CL2013
CL2028
CL2095
CL2097
CL2104
CL2103
CL2029
CL2055
CL2123
CN2001
A15
CN2001
A19
CN2001
IMSA-9730S-80A-GFC
NC
A1
CN2001
B16
CN2001
A10
CN2001
B7
CN2001
B34
CN2001
A8
CN2001
B9
CN2001
B26
CN2001
A3
CN2001
B13
CN2001
B25
CN2001
A34
CN2001
B10
CN2001
B20
CN2001
B2
CN2001
A28
CN2001
A27
CN2001
B18
CN2001
B24
CN2001
A12
CN2001
A36
CN2001
A25
CN2001
B22
CN2001
B32
CN2001
B6
CN2001
A39
CN2001
A32
CN2001
B4
CN2001
B31
CN2001
B3
CN2001
B17
CN2001
A33
CN2001
A20
CN2001
B30
CN2001
B39
CN2001
B19
CN2001
A38
CN2001
B21
CN2001
A11
CN2001
B40
CN2001
A31
CN2001
B14
CN2001
B37
CN2001
A23
CN2001
A37
CN2001
B23
CN2001
A2
CN2001
A13
CN2001
A17
CN2001
B38
CN2001
B15
CN2001
A7
CN2001
B5
CN2001
B1
CN2001
A4
CN2001
A29
CN2001
A22
CN2001
A21
CN2001
B28
CN2001
A24
CN2001
A5
CN2001
A30
CN2001
B33
CN2001
A6
CN2001
A9
CN2001
B12
CN2001
A40
CN2001
A18
CN2001
B29
CN2001
A16
CN2001
B35
CN2001
B8
CN2001
B11
CN2001
B27
CN2001
A35
CN2001
A14
CN2001
B36
CN2001
A26
R2019
NC
1
2
3
4
5
6
7
8
R2021
NC
1
2
3
4
5
6
7
8
R2015
NC
1
2
3
4
5
6
7
8
R2023
NC
1
2
3
4
5
6
7
8
R2020
NC
1
2
3
4
5
6
7
8
R2027
NC
1
2
3
4
5
6
7
8
R2016
NC
1
2
3
4
5
6
7
8
R2014
NC
1
2
3
4
5
6
7
8
R2018
NC
1
2
3
4
5
6
7
8
R2017
NC
1
2
3
4
5
6
7
8
R2028
NC
1
2
3
4
5
6
7
8
R2022
NC
1
2
3
4
5
6
7
8
+3.3VD
+3.3VD
+3.3VD
R2029 1k 63m
NC
R2001
10k
63m
NC
R2024
47
NC
R2025
47
NC
R2030
1k 63m
NC
R2026
47
NC
L2006
NC
1
2
3
4
5
6
7
8
L2001
NC
1
2
3
4
5
6
7
8
L2003
NC
1
2
3
4
5
6
7
8
L2002
NC
1
2
3
4
5
6
7
8
L2004
NC
1
2
3
4
5
6
7
8
L2005
NC
1
2
3
4
5
6
7
8
DG
DG
BM_nRESET
N.C.
N.C.
N.C.
DG
DG
BM_nPRESNT
N.C.
BM_DATA[15]
BM_DATA[14]
BM_DATA[12]
BM_DATA[13]
BM_DATA[11]
BM_DATA[10]
BM_DATA[9]
BM_DATA[8]
DG
DG
BM_DATA[6]
BM_DATA[7]
BM_DATA[5]
BM_DATA[4]
BM_DATA[3]
BM_DATA[2]
BM_DATA[1]
BM_DATA[0]
DG
DG
BM_AD[24]
BM_AD[25]
BM_AD[22]
BM_AD[23]
BM_AD[20]
BM_AD[21]
BM_AD[18]
BM_AD[19]
BM_AD[17]
BM_AD[16]
DG
DG
BM_AD[14]
BM_AD[15]
BM_AD[10]
BM_AD[11]
BM_AD[13]
BM_AD[12]
BM_AD[9]
BM_AD[8]
DG
DG
BM_AD[7]
BM_AD[6]
BM_AD[5]
BM_AD[4]
BM_AD[3]
BM_AD[2]
BM_AD[1]
BM_AD[0]
DG
DG
N.C.
N.C.
N.C.
DG
BM_nIRQ
N.C.
BM_nCS
BM_nWE[1]
BM_nBUSY
BM_nRD
BM_RD/nWR
(BM_nBS)
BM_nWE[0]
(BM_CLKIO)
N.C.
DG
N.C.
N.C.
JIGUZAGU pin No.
JIGUZAGU pin No.
Page of 127