Panasonic KX-NCP500RU Service Manual ▷ View online

ORDER NO. KMS1108838CE
Pure IP-PBX
Model No.
KX-NCP500RU
(for Russia)
2
KX-NCP500RU
TABLE OF CONTENTS
PAGE
PAGE
1 Safety Precautions -----------------------------------------------3
1.1. For Service Technicians  ---------------------------------3
1.2. Insulation Resistance Test -------------------------------3
2 Warning --------------------------------------------------------------4
2.1. Battery Caution ---------------------------------------------4
2.2. Caution--------------------------------------------------------4
2.3. About Lead Free Solder (PbF: Pb free) --------------4
2.4. Discarding of P. C. Board --------------------------------4
3 Specifications ------------------------------------------------------5
3.1. General Description ---------------------------------------5
3.2. Characteristics ----------------------------------------------5
4 Technical Descriptions------------------------------------------6
4.1. IPCMPR Block Diagram ----------------------------------6
4.2. Power Supply Block Diagram ------------------------- 10
4.3. IPCMPR Card Circuit Operation --------------------- 11
4.4. Back Board Circuit Operation ------------------------- 16
4.5. Outline ------------------------------------------------------ 17
4.6. Power Supply Unit Circuit Operation---------------- 24
5 Location of Controls and Components------------------ 30
5.1. Name and Locations ------------------------------------ 30
6 Installation Instructions--------------------------------------- 31
6.1. System Components ------------------------------------ 31
7 Operating Instructions ---------------------------------------- 36
7.1. Type and Maximum Number of Slots --------------- 36
7.2. Maximum Optional Service Cards ------------------- 37
7.3. Maximum CO Lines and Extensions ---------------- 38
7.4. Maximum Terminal Equipment ----------------------- 38
7.5. Power Supply Unit Capacity--------------------------- 39
8 Test Mode---------------------------------------------------------- 40
8.1. Utility--------------------------------------------------------- 40
9 Troubleshooting Guide---------------------------------------- 52
9.1. IPCMPR Card--------------------------------------------- 52
9.2. Power Supply --------------------------------------------- 73
10 Service Fixture & Tools --------------------------------------- 79
10.1. Extension Boards for Servicing----------------------- 79
11 Disassembly and Assembly Instructions--------------- 80
11.1. IPCMPR Card--------------------------------------------- 80
11.2. Back Board ------------------------------------------------ 81
11.3. Power Supply Board------------------------------------- 83
12 Miscellaneous ---------------------------------------------------- 84
12.1. How To Replace a Flat Package IC ----------------- 84
12.2. Terminal Guide of the ICs Transistors and
Diodes------------------------------------------------------- 85
13 Schematic Diagram--------------------------------------------- 87
13.1. Block Diagram -------------------------------------------- 87
13.2. IPCMPR Card No.1-------------------------------------- 89
13.3. IPCMPR Card No.2-------------------------------------- 91
13.4. IPCMPR Card No.3-------------------------------------- 93
13.5. IPCMPR Card No.4-------------------------------------- 95
13.6. IPCMPR Card No.5-------------------------------------- 97
13.7. IPCMPR Card No.6-------------------------------------- 99
13.8. IPCMPR Card No.7------------------------------------ 101
13.9. IPCMPR Card No.8------------------------------------ 103
13.10. IPCMPR Card No.9------------------------------------ 105
13.11. IPCMPR Card No.10 ---------------------------------- 107
13.12. IPCMPR Card No.11 ---------------------------------- 109
13.13. IPCMPR Card No.12 -----------------------------------111
13.14. IPCMPR Card No.13 -----------------------------------113
13.15. IPCMPR Card No.14----------------------------------- 115
13.16. IPCMPR Card No.15----------------------------------- 117
13.17. IPCMPR Card No.16----------------------------------- 119
13.18. Memo ------------------------------------------------------120
13.19. Back Board-----------------------------------------------121
13.20. LED Board------------------------------------------------ 126
13.21. Power Supply Board -----------------------------------127
13.22. Waveform-------------------------------------------------128
14 Printed Circuit Board-----------------------------------------130
14.1. IPCMPR Card -------------------------------------------130
14.2. Back/LED Board ----------------------------------------132
14.3. Power Supply Board -----------------------------------134
15 Appendix Information of Schematic Diagram -------136
16 Exploded View and Replacement Parts List
----------137
16.1. IC Data ----------------------------------------------------137
16.2. Cabinet and Electrical Parts Location -------------145
16.3. Accessories and Packing Material -----------------146
16.4. Replacement Parts List ------------------------------- 148
3
KX-NCP500RU
1 Safety Precautions
1. Before servicing, unplug the AC power cord to prevent an electric shock.
2. When replacing parts, use only the manufacturer's recommended components.
3. Check the condition of the power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure to perform the following insulation resistance test to prevent
the customer from being exposed to shock hazards.
1.1.
For Service Technicians 
• Repair service shall be provided in accordance with repair
technology information such as service manual so as to pre-
vent fires, injury or electric shock, which can be caused by
improper repair work.
1. When repair services are provided, neither the prod-
ucts nor their parts or members shall be remodeled.
2. If a lead wire assembly is supplied as a repair part, the
lead wire assembly shall be replaced.
3. FASTON terminals shall be plugged straight in and
unplugged straight out.
• ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help prevent
recurring malfunctions.
1. Cover plastic parts boxes with aluminum foil.
2. Ground the soldering irons.
3. Use a conductive mat on worktable.
4. Do not grasp IC or LSI pins with bare fingers.
1.2.
Insulation Resistance Test
1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with ohmmeter between the jumpered AC plug and each exposed metal cabinet part, such as
screw threads, control shafts, handle brackets, etc.
Note:
Some exposed parts may be isolated from the chassis by design. These will read infinity.
4. If the measurement is outside the specified limits, there is a possibility of shock hazard. The equipment should be repaired
and rechecked before it is returned to the customer.
4
KX-NCP500RU
2 Warning
2.1.
Battery Caution
1. Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recom-
mended by the manufacturer. Dispose of used batteries
according to the manufacturer's lnstructions. 
2. The lithium battery is a critical component (type
No.CR23541). Please observe for the proper polarity and
the exact location when replacing it and soldering the
replacement lithium battery in.
2.2.
Caution
The power socket wall outlet should be located near this
equipment and be easily accessible.
2.3.
About Lead Free Solder (PbF: Pb free)
Note:
In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that con-
tains lead.
We will use PbF when discussing the lead free solder used in our manufacturing process which is made from Tin, (Sn), Silver,
(Ag), and Copper, (Cu).
This model, and others like it, manufactured using lead free solder will have PbF stamped on the PCB. For service and repair
work we suggest using the same type of solder. 
Caution
• PbF solder has a melting point that is 50
° ~ 70° F, (30° ~ 40°C) higher than Pb solder. Please use a soldering iron with tempera-
ture control and adjust it to 700
° ± 20° F, (370° ± 10°C). 
Exercise care while using higher temperature soldering irons.:
Do not heat the PCB for too long time in order to prevent solder splash or damage to the PCB.
• PbF solder will tend to splash if it is heated much higher than its melting point, approximately 1100
°F, (600°C).
• When applying PbF solder to double layered boards, please check the component side for excess which may flow onto the
opposite side (See figure, below).
2.3.1.
Suggested PbF Solder
There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper,
(Sn+Ag+Cu), you can also use Tin and Copper, (Sn+Cu), or Tin, Zinc, and Bismuth, (Sn+Zn+Bi). Please check the manufac
turer's specific instructions for the melting points of their products and any precautions for using their product with other 
materials. 
The following lead free (PbF) solder wire sizes are recommended for service of this product: 0.3mm, 0.6mm and 1.0mm.
2.4.
Discarding of P. C. Board
When discarding P. C. Board, delete all personal informa-
tion such as telephone directory and caller list or scrap P. C.
Board.
Page of 127
Display

Panasonic KX-NCP500RU Service Manual ▷ Download

  • DOWNLOAD Panasonic KX-NCP500RU Service Manual ↓ Size: 5.46 MB | Pages: 127 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic KX-NCP500RU in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic KX-NCP500RU PBX. Information contained in Panasonic KX-NCP500RU Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.