Panasonic EP-MA51 / EP-MA51CX800 Service Manual ▷ View online
EP-MA51
ORDER NO. HPD0908A16C3
-
25 -
9.Remove the Air bags as the figure.
EP-MA51
ORDER NO. HPD0908A16C3
-
26 -
Caution in installing
Allocate Hoses as the figure and tighten them with Cable
ties –T30R.
Caution in installing
Be noted that there are the directions of top-to-bottom of
the Sole shiatsu sheets.
EP-MA51
ORDER NO. HPD0908A16C3
-
27 -
6.8. Removing the Massage mechanism block
1.Proceed all the procedures of 6.4. Removing the Rear
cover.
2.Move down the Massage mechanism block to the lowest
position by the Controller.
3.Unscrew four Screws, and remove the Massage
mechanism block cover.
4.Unscrew the Screw, and disconnect three Connectors.
5.Cut the Cable tie, and pull off the Connecting cord for the power
source from the Massage mechanism block cover clip.
6.Unscrew Screws four each from right/left, and remove the Rail
piece right/left.
Caution
Hold the Massage mechanism block, because it may fall
forward a little.
EP-MA51
ORDER NO. HPD0908A16C3
-
28 -
Be careful of the directions of right/left when installing the
Rail piece right/left.
Caution when handling the Massage mechanism block
Be sure to handle the Massage mechanism block carefully so
that the PCB of the Pressure sensor is not pushed to the desk or
given extra pressure when putting the Massage mechanism
block, which could lead to the cracks of the PCB. This may
eventually cause the malfunction such as ‘The Body pressure
levels on the Controller does not increase.’ ‘It does not scan.’ Or
‘The operation is not stable.’ etc.
Click on the first or last page to see other EP-MA51 / EP-MA51CX800 service manuals if exist.