Panasonic SDR-SW20P / SDR-SW20PC / SDR-SW20PL / SDR-SW20E / SDR-SW20EB / SDR-SW20EE / SDR-SW20EF / SDR-SW20EG / SDR-SW20EP / SDR-SW20GC / SDR-SW20GN / SDR-SW28GK Service Manual ▷ View online
29
8.3.22. Removal of the Master flange, 4th
moving frame unit and 3rd moving
frame unit
frame unit
Fig. D33
8.3.23. Removal of the Guide pole S, Guide
pole and 2nd moving frame unit
Fig. D34
30
9 Measurements and Adjustments
9.1.
Electric Adjustment
• Adjustment method is different from a conventional SD video camera.
• An exclusive jig and PC (including software for adjustment “Tatsujin”) are necessary for electric adjustment.
• A USB driver for service is necessary to communication with PC.
• Connection method of the main unit and an exclusive adjustment jig as follows
• An exclusive jig and PC (including software for adjustment “Tatsujin”) are necessary for electric adjustment.
• A USB driver for service is necessary to communication with PC.
• Connection method of the main unit and an exclusive adjustment jig as follows
9.1.1.
Adjustment Procedure
• Connect the main unit to PC with USB.
The adjustment instruction is available at "Software download" on the "Support Information from NWBG/VDBG-PAVC" web-site
in "TSN System".
in "TSN System".
Figure of connection
Figure of image when adjustment
Part Number of jig
• Only a necessary jig mentions it in setup of electric adjustment.
No.
Part Name
Part Number
Remarks
1
PC
------
2
AC Adaptor
------
3
AC Cable
------
4
USB Cable
------
5
Adjustment Software (Tatsujin)
------
31
Adjustment Items
• Adjustment item as follows.
The adjustment instruction is available at "Software download" on the "Support Information from NWBG/VDBG-PAVC" web-site
in "TSN System".
in "TSN System".
9.2.
Repair Record
Using the applicable items in (Repair & Maintenance) that is newly provided in the adjustment software, record the treatment and
the date of execution.
the date of execution.
32
10 Factory Setting
10.1. HOW TO TURN ON THE FACTORY SETTINGS?
1. Set the mode dial to the Motion picture recording position.
2. Press three buttons (“Cursor button [Right]”, “Delete button” and “Record button” simultaneously for 3 seconds or more.
2. Press three buttons (“Cursor button [Right]”, “Delete button” and “Record button” simultaneously for 3 seconds or more.
3. Beep tone is generated and then the shutter sound is generated.
4. When “END” appears on the display, the Factory Setting is completed.
5. Set the mode dial to the OFF position to close the Factory Setting.
4. When “END” appears on the display, the Factory Setting is completed.
5. Set the mode dial to the OFF position to close the Factory Setting.
10.2. WHAT IS THE FACTORY SETTINGS?
The factory settings clean up and/or refresh the following settings.
1. The OSD MENU setting data.
2. Deletion only for all scene files in a card and format of the MPEG2 file system area.
3. Reset the folder number and file number of still pictures.
2. Deletion only for all scene files in a card and format of the MPEG2 file system area.
3. Reset the folder number and file number of still pictures.
(Setting the folder number is 100, and file number is 0.)
4. Clear the mechanism lock information.
5. Clear the service mode information contents.
5. Clear the service mode information contents.
The setting position of factory settings:
Name
Setting position
Mode dial
OFF
Click on the first or last page to see other SDR-SW20P / SDR-SW20PC / SDR-SW20PL / SDR-SW20E / SDR-SW20EB / SDR-SW20EE / SDR-SW20EF / SDR-SW20EG / SDR-SW20EP / SDR-SW20GC / SDR-SW20GN / SDR-SW28GK service manuals if exist.