DOWNLOAD Panasonic NN-ST340W / NN-SM330W / NN-SM330WZPE / NN-ST340WZPE Service Manual ↓ Size: 2.71 MB | Pages: 35 in PDF or view online for FREE

Model
NN-ST340W NN-SM330W NN-SM330WZPE NN-ST340WZPE
Pages
35
Size
2.71 MB
Type
PDF
Document
Service Manual
Brand
Device
Home Appliance / MICROWAVE OVEN
File
nn-st340w-nn-sm330w-nn-sm330wzpe-nn-st340wzpe.pdf
Date

Panasonic NN-ST340W / NN-SM330W / NN-SM330WZPE / NN-ST340WZPE Service Manual ▷ View online

6.6. Turntable motor
 1. Remove the motor cover by breaking off at the 4 spots
indicated by arrows with a cutter or the like.
NOTE:
After removing the motor cover, be sure that cut
portions are properly trimmed off or bent to the
inside so that no sharp edges will be exposed to
outside.
 2. Disconnect 2 lead wires connected to the turntable motor.
 3. Remove the turntable motor by removing 1 screw.
NOTE:
After reinstalling the new turntable motor and
reconnecting the 2 lead wires, reinstall the motor
cover by rotating it around 180°, tucking the 2 tabs
under the base into the 2 provided slots, then screw
the single tab to the base using a 4mm x 6mm
screw.
17
NN-ST340W / NN-SM330W
WARNING
1. High voltage is present at the high voltage terminal of the high
voltage transformer during any cook cycle.
2. It is neither necessary nor advisable to attempt measurement of the
high voltage.
3. Before touching any oven components, or wiring, always unplug
the power cord and discharge the high voltage capacitor (see page
12).
7.1. Primary, Secondary Latch
Switch Interlocks
 1. Unplug lead connectors to Primary Latch Switch and
Secondary Latch Switch.
 2. Test the continuity of switches at door opened and closed
positions with ohm meter (low scale).
Normal continuity readings should be as follows.
7.2. Short Switch & Monitor
 1. Unplug lead wires from H.V.transformer primary terminals.
 2. Connect test probes of ohm meter to the disconnected
leads of the H.V. Transformer.
 3. Test the continuity of Short Switch with door opened and
closed positions using lowest scale of the ohm meter.
Normal continuity readings should be as follows.
7.3. High voltage transformer
 1. Remove connectors from the transformer terminals and
check continuity.
 2. Normal (cold) resistance readings should be as follows:
Secondary winding......................... Approx. 195
Ω~240 Ω
Filament winding.............................. Approx. 0
Primary winding................................. Approx. 0
Ω ~3 Ω
7.4. High voltage capacitor
 1. Check continuity of capacitor with meter on highest OHM
scale.
 2. A normal capacitor will show continuity for a short time, and
then indicate 9M
Ω once the capacitor is charged.
 3. A shorted capacitor will show continuous continuity.
 4. An open capacitor will show constant 9M
Ω.
 5. Resistance between each terminal and chassis should be
infinite.
7.5. Magnetron
Continuity checks can only indicate an open filament or a
shorted magnetron. To diagnose for an open filament or
shorted magnetron:
 1. Isolate magnetron from the circuit by disconnecting the
leads.
 2. A continuity check across magnetron filament terminals
should indicate one ohm or less.
 3. A continuity check between each filament terminal and
magnetron case should read open.
7 COMPONENT TEST PROCEDURE
18
NN-ST340W / NN-SM330W
7.6. Diode
 1. Isolate the diode from the circuit by disconnecting the leads.
 2. With the ohmmeter set on the highest resistance scale,
measure the resistance across the diode terminals.Reverse
the meter leads and again observe the resistance
reading.Meter with 6V, 9V or higher voltage batteries should
be used to check the front-to-back resistance of the diode,
otherwise an infinite resistance may be read in both
directions.
A normal diode’s resistance will be infinite in one direction
and several hundred K
Ω in the other direction.
7.7. Variable power controller (NN-
SM330W)
 • Isolate variable power switch from the circuit by
disconnected 2 leads.
 • In order to check if variable power controllor is operating
normally, follow the test procedures below.
 1. Select any power other than “High“ and start the oven.
 2. Check continuity between both terminals of the variable
power switch.
 3. Variable power controller (timer and variable power
switch) is working proporty it the ohm meter reads open
and 0
Ω within 30 ± 1 seconds interval as shown in table
on P.11.
7.8. Membrane keyboard
(Membrane switch assembly)
(NN-ST340W)
Check continuity between switch terminals, by tapping an
appropriate pad on the key board. The contacts assignment of
the respective pads on the key board is as shown in digital
programmer circuit.
19
NN-ST340W / NN-SM330W
8.1. Adjustment of Primary latch
switch, Secondary latch
switch and Short switch.
 1. Mount the Primary latch swith, the Secondary latch switch
and the Short switch to the door hook assembly as shown
in ILL.
NOTE:
No
specific
individual
adjustments
during
installation of the Primary latch switch, Secondary
latch switch or Short switch to the door hook are
required.
 2. When mounting the door hook assembly to the oven
assembly, adjust the door hook assembly by moving it in
the direction of the arrows in the illustration so that the oven
door will not have any play in it. Check for play in the door
by pulling the door assembly. Make sure that the latch keys
move smoothly after adjustment is completed. Completely
tighten the screws holding the door hook assembly to the
oven assembly.
 3. Reconnect the short switch and check the coninuity of the
monitor circuit and all latch switches again by following the
component test procedures.
8.2. Measurement of microwave
output
The output power of the magnetron can be determined by
performing IEC standard test procedures. However, due to the
complexity of IEC test procedures, it is recommended to test
the magnetron using the simple method outlined below.
Necessary Equipment:
 • 1 liter beaker
 • Glass thermometer
 • Wrist watch or stopwatch
NOTE:
Check the line voltage under load.Low voltage will
lower the magnetron output. Take the temperature
readings and heating time as accurately as possible.
 1. Fill the beaker with exactly one liter of tap water. Stir the
water using the thermometer and record the water’s
temperature. (recorded as T1).
 2. Place the beaker on the center of glass tray.
Set the oven for High power and heat it for exactly one
minute.
 3. Stir the water again and read the temperature of the water.
(recorded as T2).
 4. The normal temperature rise at High power level for each
model is as shown in table.
TABLE (1L-1min. test)
RATED OUTPUT
TEMPERATURE RISE
700W
Min.6.0°C
800W
Min.7.0°C
8 MEASUREMENTS AND ADJUSTMENTS
20
NN-ST340W / NN-SM330W
Page of 35
Display

Click on the first or last page to see other NN-ST340W / NN-SM330W / NN-SM330WZPE / NN-ST340WZPE service manuals if exist.