Panasonic NN-GF574MZPE Service Manual ▷ View online

Discharging the high voltage capacitors
WARNING
There is high voltage present with high current capabilities
in the circuits of the primary and secondary windings, choke
coil and heat sinkof the inverter. It is extremely dangerous
to work on or near these circuits with the oven energized.
DO NOT measure the voltage in the high voltage circuit
including the filament voltage of the magnetron.
WARNING
Never touch any circuit wiring with your hand or with an
insulated tool during operation.
5.3. Part replacement.
When troubleshooting any part or component is to be replaced,
always ensure that the power cord is unplugged from the wall
outlet.
5.4. When the 10A fuse is blown
due to the malfunction of the
short switch:
WARNING
When the 10A 250V fuse is blown due to the malfunction of
the short switch, replace all of the components (primary
interlock switch, short switch and power relay RL1).
 1. This is mandatory. Refer to “measurements and
adjustments” for the location of these switches.
 2. When replacing the fuse, confirm that it has the
appropriate rating for these models.
 3. When replacing faulty switches, be sure the mounting
tabs are not bent, broken or deficient in their ability to
hold the switches.
5.5. Avoid inserting nails, wire etc.
through any holes in the unit
during operation.
Never insert a wire, nail or any other metal object through the
lamp holes on the cavity or any holes or gaps, because such
objects may work as an antenna and cause microwave
leakage.
5.6. Verification after repair
 1. After repair or replacement of parts, make sure that the
screws of the oven, etc. are neither loosen or missing.
Microwave energy might leak if screws are not properly
tightened.
 2. Make sure that all electrical connections are tight before
inserting the plug into the wall outlet.
 3. Check for microwave energy leakage.
CAUTION OF MICROWAVE RADIATION LEAKAGE
USE CAUTION NOT TO BECOME EXPOSED TO
RADIATION FROM THE MICROWAVE MAGNETRON OR
OTHER PARTS CONDUCTING MICROWAVE ENERGY.
IMPORTANT NOTICE
 1. The following components have potentials above 2000V
while the appliance is operated.
  • Magnetron
  • High voltage transformer (Located on inverter (U))
  • High voltage diodes (Located on inverter (U))
  • High voltage capacitors (Located on inverter (U))
Pay special attention to these areas.
 2. When the appliance is operated with the door hinges or
magnetron installed incorrectly, the microwave leakage
can exceed more than 5mW/cm
2
. After repair or
exchange, it is very important to check if the magnetron
and the door hinges are correctly installed.
5.7. Sharp edges
CAUTION
Please use caution when disassembling or reassembling
internal parts. Some exposed edges may be sharp to the
touch and can cause injury if not handled with care.
9
NN-GF574M
6.1. Inverter power supply
CAUTIONS
1. Always leave the grounding plate in place.
2. Always securely tighten the ground screw through the bottom of the
chassis (base).
3. Securely connect 3 lead wire connectors.
4. Make sure the heat sink has enough space (gap) from the oven.
Take special care not to dress any lead wire over the aluminum heat
sink because it is hot.
 1. Discharge high voltage remaining in high voltage capacitor.
 2. Disconnect 2 high voltage lead wires from magnetron
filament terminals.
 3. Disconnect connector CN701 & CN702 from H.V. Inverter
board.
 4. Remove 4 screws holding inverter reinforcement bracket A
on right heater panel & base plate respectively.
 5. Release locking tabs connecting inverter air guide with
inverter bracket.
 6. Remove 1 screw holding H.V.Inverter to Inverter bracket.
 7. Remove 1 screw holding grounding plate to H.V. Inverter.
6 DISASSEMBLY AND PARTS REPLACEMENT
PROCEDURE
10
NN-GF574M
6.2. Magnetron
 1. Steps same as disassembly of H.V. Inverter step 1 to step
4.
 2. Remove 1 screw holding thermistor on magnetron.
 3. Remove 2 screws holding air guide F on magnetron.
 4. Remove 4 screws holding the magnetron.
NOTE:
After replacement of the magnetron, tighten mounting
screws properly in an x pattern, making sure there is no
gap between the waveguide and the magnetron to
prevent microwave leakage.
CAUTION
When replacing the magnetron, be sure the antenna gasket is in
place.
6.3. Digital programmer circuit
(D.P.C) & Membrane Switch
NOTE:
Be sure to ground any static electric charge built up on
your body before handling the D.P.C.
 1. Remove 1 screw holding reinforcement bracket and
escutcheon base on front plate.
 2. Disconnect all connectors from D.P.C. board.
11
NN-GF574M
 3. Disconnect connector CN701 from H.V. Inverter board.
 4. Remove 6 screws holding D.P.C. board on escutcheon
base.
 5. Separate D.P.C board from tabs on the escutcheon base
and remove D.P.C board.
To replace membrane key board
 6. Use tools such as kinfe etc. to lift the edge of membrane
sheet and peel off escutcheon sheet & key board
membrane completely from escutcheon base.
NOTE:
 a. The membrane key board is attached to the
escutcheon base with double faced adhesive tape.
Therefore, applying hot air such as using a hair dryer
is recommended for smoother removal.
 b. When installing the new key board membrane, make
sure that the surface of escutcheon base is clean to
prevent a malfunction or shorted contacts.
12
NN-GF574M
Page of 33